Onlogic Factor 202 Product Manual Download Page 37

53

NC

NC

54

55

NC

NC

56

57

GND

NC

58

59

NC

NC

60

61

NC

NC

62

63

NC

NC

64

65

NC

NC

66

67

RESET_N

SUSCLK

68

69

CONFIG_1

3.3V

70

71

GND

3.3V

72

73

GND

3.3V

74

75

CONFIG_2

6.6 Appendix E: Safety Information

Do not open or modify the device. The device uses components that comply with FCC and CE
regulations. Modification of the device may void these certifications.

6.6.1 Safe Use and Installation Instructions

1. Install the device securely. Be careful handling the device to prevent injury and do not drop.

2. Wall or ceiling mounting the device requires use of a mounting plate or bracket. The plate or

bracket must be of metal construction and have a minimum thickness of 1mm.

3. Use M4x0.5mm Flat Head screws to attach mounting plate or mounting brackets to threaded

holes on bottom or rear of chassis. Screws should be a minimum length of 4mm. Add 1mm

of screw length for every mm of additional thickness of plate or bracket beyond 1.5mm.

4. Ambient operating temperature must be between 0 °C to 60 °C with a non-condensing relative

humidity of 10-90%.

5. The device can be stored at temperatures between -10 °C to 85 °C.

6. Keep the device away from liquids and flammable materials.

7. Do not clean the device with liquids. The chassis can be cleaned with a cloth.

8. Allow at least 2 inches of space around all sides of the device for proper cooling. It is

recommended to mount the device such that the metal side plates are vertical to allow air to

rise unobstructed. Alternative orientations may result in reduced operational temperature

range.

9. This device is intended for indoor operation only.

10. Use only antennas provided.  Maintain 20cm of distance from the antenna.

11. Use UL Listed external power supply with rated output 12Vdc

12. Install the device only with shielded network cables.

13. Only use SAE approved cables for automotive installation.

14. The installer should be experienced in aftermarket installation and familiar with general

practices for installing electronics devices in vehicles.

15. The device should not be installed in the driver’s area of a vehicle.

37

Summary of Contents for Factor 202

Page 1: ...FR202 Product Manual ...

Page 2: ...ntroduction 5 1 2 In box Accessories 5 1 3 Product Specifications 6 1 4 Exterior Features and Dimensions 10 1 4 1 Top I O 10 1 4 2 Bottom I O 10 1 4 3 Factor 202 Dimensions FR202 11 1 5 System Block Diagrams 12 2 I O Definitions 13 2 1 Top I O Definition 13 USB C Config Port CM4 Update 13 HDMI 13 USB 3 2 Gen1 5Gb s 13 USB 2 0 13 2 ...

Page 3: ...CM4 output 19 LAN2 Realtek RTL8153B 20 Analog Temperature Inputs 22 SPI I2C UART RS485 Header 24 Front Display 24 2 3 Motherboard Connectors 26 M 2 B Key 27 Boot Function Jumper Header 27 RTC Battery Header 28 Raspberry Pi Header 28 DSI Header Not Populated 29 CSI Header Not Populated 29 POE Add on Connector 30 CM4 Headers 30 MCU Update Header 30 3 Mounting Instructions 30 4 Power Management 30 4 ...

Page 4: ...ption 33 6 3 Appendix B Software Documentation 34 6 4 Appendix C System Thermal Results 35 6 5 Appendix D Expansion Port Pinout 37 6 5 1 M 2 B Key MODEM 37 6 5 2 M 2 B Key SATA 38 6 6 Appendix E Safety Information 39 6 6 1 Safe Use and Installation Instructions 39 6 6 2 Instructions d utilisation et d installation en toute sécurité 40 4 ...

Page 5: ...oT gateway edge device or customizable industrial controller the Factor 202 is the industrial Raspberry Pi solution you ve been waiting for 1 2 In box Accessories 1x Power Terminal Block 1x COM Terminal Block 7x IO Terminal Block If you purchased additional items such as mounting brackets power supplies or terminal block connectors they will be located in the system box or within the outer shippin...

Page 6: ... 0 20mA 4 20mA 4 24mA 2x Temperature input RT100 1000 1x SPI I2C UART RS485 Header Front I O 1x USB 3 2 5Gb s 2x USB 2 0 1x HDMI 1x USB C for CM4 Programming 1x Reset button 16x Digital input Isolated 16x Digital Output Isolated Onboard Headers Connectors 1x Battery on a cable 1x Raspberry Pi Expansion Header Female 1x SPI TPM Header 1x CM4 Boot Mode Select 1x PoE PD Header 1x USB2 Modem Header Vo...

Page 7: ...h 22 MHz 5 GHz 802 11a n ac 20 40 80 160 MHz RF output power 19 dBm 2400 2485 MHz IEEE 802 11b g n BT 10 dBm 2400 2485 MHz BLE 23 dBm 5150 5725 MHz IEEE 802 11a n ac 13 98 dBm 5725 5875 MHz IEEE 802 11a n ac Type of Antenna 1x Reference antenna is PIFA type 2 dBi 2 dBi gain external terminal Radio Specifications when equipped with Amit MDG100 EU GPS Receiver Operating frequency range 1559 1610 MHz...

Page 8: ...8 Operating frequency range 880 915 MHz 925 960 MHz Maximum output power 23dBm rated LTE FDD Band 20 Operating frequency range 832 862 MHz 791 821 MHz Maximum output power 23dBm rated LTE FDD Band 28A Operating frequency range 703 733 MHz 758 788 MHz Maximum output power 23dBm rated LTE FDD Band 38 Operating frequency range 2570 2620 MHz Maximum output power 23dBm rated LTE FDD Band 40 Operating f...

Page 9: ...uency range 1710 1755 MHz 2110 2155 MHz Maximum output power 24dBm rated WCDMA Band 5 Operating frequency range 824 849 MHz 869 894 MHz Maximum output power 24dBm rated LTE FDD Band 12 Operating frequency range 699 716 MHz 729 746 MHz Maximum output power 23dBm rated LTE FDD Band 13 Operating frequency range 777 787 MHz 758 768 MHz Maximum output power 23dBm rated LTE FDD Band 14 Operating frequen...

Page 10: ...1 4 Exterior Features and Dimensions 1 4 1 Top I O 1 4 2 Bottom I O 10 ...

Page 11: ...1 4 3 Factor 202 Dimensions FR202 11 ...

Page 12: ...1 5 System Block Diagrams 12 ...

Page 13: ...ate function modes and power output are not supported on this connector HDMI FR201 uses the CM4 s integrated HDMI to drive the external HDMI Port Resolutions up to 4096x2304 60Hz are supported CEC Consumer Electronics Control functionality is also supported depending on software configuration USB 3 2 Gen1 5Gb s One USB 3 2 Gen1 5Gb s port is provided for peripherals or boot media By default this p...

Page 14: ... GND DI terminal pinout 16 optically isolated digital inputs are provided via 2 10 pin terminal block connecters Dinkle 0221 2010 or equivalent Performance is optimized for 12 24V operation Each group of 4 inputs DI0 3 DI4 7 DI8 11 and DI12 15 is software configurable to active high or active low The active low configuration activates internal pull ups to the VCC pin of the same header If the acti...

Page 15: ... Active Low Sinking Output Compatible Input Wiring Active High Sourcing Output Compatible Input Wiring 15 ...

Page 16: ...2010 or equivalent Performance is optimized for 12 24V operation Operating voltage should not exceed 24V Each output has a 0 5A resettable fuse Each group of 4 outputs DO0 3 DO4 7 DO8 11 and DO12 15 is software configurable to sourcing or sinking high or low side switched For all configurations customers must supply a VCC and GND connection on the same connector as the outputs in use No power is s...

Page 17: ...Sourcing Output Wiring 17 ...

Page 18: ...Sinking Output Wiring 2 2 Bottom I O Definition 18 ...

Page 19: ... terminal power pinout 5 Pin COM Terminal Block The serial port supports RS 232 RS 422 and RS 485 configurations by way of a 5 pin terminal block connector Mating part Dinkle 0221 2005 or equivalent The mode can be selected from within the operating system using available configuration tools See FR201 software documentation for details Pin RS 232 RS 422 RS 485 1 GND GND GND 2 NC TX TX RX 3 NC RX N...

Page 20: ... Off Orange Slow Blink 1000 Mb s data rate LAN activity light description LAN2 Realtek RTL8153B The second LAN Port on FR201 supports up to 1Gbps link speeds over standard shielded CAT5e or CAT6 cables The connector is the industry standard RJ45 connector The LAN link state is shown by the two LEDs enclosed in the port The description is included below Activity is also indicated by the LAN2 LED on...

Page 21: ...software configuration An application to configure and use the analog inputs is provided by OnLogic and ships in OnLogic installed operating systems Calibration updates can be made in the application by adjusting the scaling factor applied as measurements are computed For details of use see the FR200 software documentation Temperature inputs may be connected to 2 3 or 4 wire sensors Excitation cur...

Page 22: ...Analog Voltage Input Wiring Analog Current Input Wiring 4 Wire Temperature Sensor Wiring 2 Wire Temperature Sensor Wiring 22 ...

Page 23: ...essary internal pull ups on the SPI and I2C interfaces are provided Depending on the length and configuration of the external wiring customers may need to provide additional components for signal conditioning Front Display A 320x240 full color backlit display with capacitive touchscreen is provided for customer use for displaying diagnostic or setup information It can be configured as an additiona...

Page 24: ...2 3 Motherboard Connectors Item Function Description A1 USB C USB 2 0 for CM4 Firmware Update A2 HDMI A3 TPM A4 USB 3 2 A5 USB 2 0 x2 A6 Pinhole Reset Button A7 Raspberry Pi Header A8 Power Input 24 ...

Page 25: ...rm factor without The B Key connector on the FR201 platform supports PCIe Gen 3 x2 USB 3 2 5Gb s USB 2 0 SATA Gen I 1 5Gbps SATA Gen II 3 0Gbps and SATA Gen III 6 0Gbps devices A full pinout table for this expansion slot is provided in Appendix D Boot Function Jumper Header A 2mm pin header and jumpers are used to configure some CM4 boot settings To enable write protect for the bootloader short pi...

Page 26: ... IO board and the motherboard The pinout and description are provided here as a reference The Raspberry Pi header is designed to mimic the header on the standard Raspberry Pi 4 with additional features For a detailed list of standard features that this header supports see the Raspberry Pi documentation The connector on the Factor 201 is female but is pinned such that a developer can install a male...

Page 27: ...IO12 34 GPIO13 33 GND 36 GPIO19 35 GPIO16 38 GPIO26 37 GPIO20 40 GND 39 GPIO21 42 USB2_DN 41 USB2_DP Raspberry Pi header pinout DSI Header Not Populated The DSI MIPI display header is pinned identically to the Raspberry Pi 4 DSI header but is not implemented or installed by default and is not supported at this time CSI Header Not Populated The CSI MIPI camera header is pinned identically to the Ra...

Page 28: ... options and instructions see the FR202 Spec Sheet Dimensional Drawings 4 Power Management 4 1 Protection Circuitry Parameter Value Nominal operating voltage Rated DC value of input 12 24V Undervoltage protection trip DC level system turns off 6 5V Maximum safe DC voltage system not damaged 27V These DC levels specified are the absolute max values for the pins for function and safety of the system...

Page 29: ...at may cause undesired operation 5 3 ISED This device complies with Industry Canada license exempt RSS standard s Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d Industrie Canada applicables a...

Page 30: ...30 ...

Page 31: ...n the tables below The configurations below are using representative samples of internal devices the specific components mentioned below may vary from the devices provided by OnLogic System Component Config 1 Low Config 2 Mid Config 3 High CPU CM4 BCM2711 CM4 BCM2711 CM4 BCM2711 Memory 2GB 4GB 8GB SATA Storage none Innodisk DEM28 A28M41BW1DC 27 Innodisk DEM28 A28M41BW1DC 27 M 2 B Key Modem none no...

Page 32: ... 4 Core Stress 9 6 10 0 Config 3 High Power Consumption 12V W 24V W OS Idle 7 3 7 5 CPU 1 Core Stress 9 4 9 6 CPU 4 Core Stress 10 2 10 4 6 3 Appendix B Software Documentation For a detailed overview of the configuration and individual settings please refer to the OnLogic support site Instructions for updating the BIOS can also be found on the support site Please refer to the link below for detail...

Page 33: ...iety of thermal conditions the thermal chamber temperature was raised from 40 C to 60 C with a 4 hour dwell at each 5 increment The results were analyzed by comparing the average clock speed over the duration of the test to the expected base clock speed CPU throttling was observed beginning at 50 C with performance gradually decreasing to just above the maximum throttle state 600 MHz at 60 C FR202...

Page 34: ...02 4 Core 75 Load Thermal Testing Component Results the graph below shows the key component temperature values from the above test The table is the maximum observed temperature and component test limits 34 ...

Page 35: ...D WAN_ACT_N 10 11 GND KEY 12 13 KEY KEY 14 15 KEY KEY 16 17 KEY KEY 18 19 KEY NC 20 21 NC NC 22 23 NC NC 24 25 NC NC 26 27 GND NC 28 29 USB3 1 Rx NC 30 31 USB3 1 Rx NC 32 33 GND NC 34 35 USB3 1 Tx NC 36 37 USB3 1 Tx NC 38 39 GND NC 40 41 NC NC 42 43 NC NC 44 45 GND NC 46 47 NC NC 48 49 NC PERST 50 51 GND NC 52 53 NC NC 54 55 NC NC 56 57 GND NC 58 59 NC NC 60 61 NC NC 62 35 ...

Page 36: ...3V 4 5 GND FULL_CARD_POWER_OFF 6 7 NC W_DISABLE1 8 9 NC SSD_LED_ACT_N 10 11 GND KEY 12 13 KEY KEY 14 15 KEY KEY 16 17 KEY KEY 18 19 KEY NC 20 21 CONFIG_0 NC 22 23 NC NC 24 25 NC NC 26 27 GND NC 28 29 NC NC 30 31 NC NC 32 33 GND NC 34 35 NC NC 36 37 NC NC 38 39 GND NC 40 41 SATA B NC 42 43 SATA B NC 44 45 GND NC 46 47 SATA A NC 48 49 SATA A PERST 50 51 GND NC 52 36 ...

Page 37: ... 5mm 4 Ambient operating temperature must be between 0 C to 60 C with a non condensing relative humidity of 10 90 5 The device can be stored at temperatures between 10 C to 85 C 6 Keep the device away from liquids and flammable materials 7 Do not clean the device with liquids The chassis can be cleaned with a cloth 8 Allow at least 2 inches of space around all sides of the device for proper coolin...

Page 38: ...à l écart des liquides et des matériaux inflammables 7 Ne nettoyez pas l appareil avec des liquides Le châssis peut être nettoyé avec un chiffon 8 Laissez au moins 2 pouces d espace autour de tous les côtés de l appareil pour un refroidissement correct Il est recommandé de monter l appareil de manière à ce que les plaques latérales métalliques soient verticales pour permettre à l air de monter san...

Page 39: ...correctement L élimination de la batterie dans le feu ou dans un four chaud ou l écrasement ou le découpage mécanique d une batterie peut entraîner une explosion 39 ...