background image

9

Recording

Stopping recording

Press the 

e

 button.

Interrupting recording briefly

Press the 

t

 button.

9

10

e

9. Put the source component into

recording standby status.

• Temporarily stop CD (or LP) play.
• Rewind the tape to the portion you wish

to start playback.

10. Press the 

s

 button on this unit and

begin playing the source component.

You can also use the CD Synchro
Recording function if this unit is prop-
erly connected to an ONKYO CD player
bearing the 

z

 symbol.

Making good sound recordings

s

DUBB.STOP

t

Dolby Noise Reduction System
Dolby B NR is the system used in most cassette tape decks to
reduce the background noise that is inherent in all cassette tapes.
Dolby Laboratories then developed an even more effective noise
reduction system, Dolby C NR, in response to the demand for
increasingly better sound quality from cassette tapes.

Both Dolby noise reductions systems operate by boosting

signals during recording that fall below a certain input level.
Dolby B and C NR operate on the higher portions of the fre-
quency spectrum using what is called a “sliding band” technique.
This is because tape hiss is most prominent during the quiet, high
frequency portions of a recording. These same signals are then
reduced back to their original strength during playback, thereby
reducing the background noise by the same amount. In order to
operate only when necessary, the Dolby NR system has a varying
effect depending on the input level and frequency of the material
being recorded.

Dolby C NR is capable of reducing tape hiss by 10 dB more

than Dolby B NR. In addition to its noise reducing function,
Dolby C NR has an anti-saturation network that lowers high input
levels before recording them and returns the signals to their
original strength during playback. This raises the high-frequency
saturation level of cassette tapes to allow you to record signals
that would normally cause distortion. This system raises the
maximum output level of cassette tapes by more than 4 dB at 10
kHz.

Setting the Proper Recording Level
The recording level has an important effect on the sound quality a
tape will have when it is played back. A recording level that is
too high will cause distortion while one which is too low will
lower the signal-to-noise ratio resulting in a tape with excessive
“hiss noise.” It is particularly important to set the recording level
correctly with cassette tapes since they have a much thinner
magnetic coating than open reel tapes. The thin coating gives the
tape a comparatively low saturation level which can easily be
surpassed if the recording level is set too high.
The recording level indicators feature a peak-hold function for the
indicators from -6 dB t6 dB. This can come in handy
when setting the recording level.

CD Synchro Recording System
Once the TA-RW244/144 is connected to a CD player bearing the

z

 mark (see page 12), press the 

s

 button of the CD player will

cause recording to start automatically on the TA-RW244/144.
1. Insert a cassette with the side to be recorded facing out.
2. Start the CD player.
3. Press the 

t

 button to place the unit in the recording standby

mode. Adjust the input level. When the recording level has
been set, stop the CD player.

4. Start the CD player again, and recording will begin simultane-

ously.

Notes:
1. Even if the CD player is stopped during recording, the cassette

deck will continue recording.

2. If the cassette deck is in the recording standby mode when the

CD is put in play, the deck will begin recording. When setting
recording levels, always start the CD first.

Summary of Contents for TA-144

Page 1: ...ding functions 11 Connecting ONKYO components for z operation 12 Handling cassette tapes 13 Cassette deck maintenance 14 Specifications 14 Troubleshooting guide 15 CONTENTS Instruction Manual Stereo C...

Page 2: ...placement and mounting of an AC plug on the power supply cord of this unit should be performed only by qualified service personnel IMPORTANT The wires in the mains lead are coloured in accordance with...

Page 3: ...sture The appliance should not be used near water for example near a bathtub washbowl kitchen sink laundry tub in a wet basement or near a swimming pool and the like 6 Carts and Stands The appliance s...

Page 4: ...utton NORMAL HIGH 10 6 COUNTER A B button 8 7 Deck B r EJECT button 8 8 COUNTER RESET button 8 9 Deck B cassette holder 8 10 REC LEVEL control knob 8 11 Deck B operation buttons t Rec pause button 8 A...

Page 5: ...nents for z operation on page 12 Power connections Switching power on TA RW144 1 Plug the AC power cord into a wall outlet The STAND BY indicator will light 2 Press the POWER button The STAND BY indic...

Page 6: ...by pressing the DOLBY NR button repeatedly until the proper Dolby NR indicator OFF B or C turns on Select the same noise reduction system that was used when the cassette was recorded For instance tap...

Page 7: ...a tape Continuous tape playback Insert the cassettes you wish to play in Deck A and Deck B Set the reverse mode to b Press the a or s button of either Deck A or Deck B Both sides of both cassettes wi...

Page 8: ...the COUNTER RESET button to return the tape counter to 0000 6 Begin playing the source component 7 Press the t button 8 While observing the peak level indicators adjust the recording level The record...

Page 9: ...els before recording them and returns the signals to their original strength during playback This raises the high frequency saturation level of cassette tapes to allow you to record signals that would...

Page 10: ...tape are copied 3 Check the Deck A and Deck B direction indicators to ensure that the tape will start in the desired direction To dub an entire tape be sure to select the forward s direction on both D...

Page 11: ...seconds long The PLAY indicator flashes on and off After the blank space has been inserted the tape stops automatically and the deck returns to the rec pause mode 3 To continue recording press the a o...

Page 12: ...ion The function listed below can be accom plished using the remote control of the master unit s a Play d Rewind f Fast forward e Stop t Rec Pause CD synchro recording system Once connections are made...

Page 13: ...not to cover the holes for detecting high position tapes Loose tape Loose tape can cause tangling around the pinch roller and capstan and jam the mechanism Remove any tape slack with a pencil or simi...

Page 14: ...lable head eraser once every 50 hours of use Refer to the instruction manual of the head eraser for detailed instructions Specifications Track Format 4 track 2 channels Erasure System AC erase Tape Sp...

Page 15: ...at too high a level Remedy Readjust REC LEVEL knob according to the directions on page 8 Tape squeal and skipping Cause Dirty heads pinch rollers or capstan shafts Remedy Clean see page 14 Cause Cass...

Page 16: ...ms Drive Ramsey N J 07446 U S A Tel 201 825 7950 Fax 201 825 8150 E mail onkyo onkyousa com ONKYO EUROPE ELECTRONICS GmbH Industriestrasse 18 20 82110 Germering GERMANY Tel 089 84 93 20 Fax 089 84 93...