DV-SP504
TEST MODE/ CONFIRM FW
1.
Confirm Region code
1-1. Press "
Dimmer
" key and "
Pause
" key at the same time.
1-2. Press "
Pause
" key. Display "Region Code " on the FL tube.
MDD1N : USA 1 NTSC
MJJ2N : JPN 2 NTSC
MUK3N : ASIA 3 NTSC
MUP2P : EURO 2 PAL
MUT3P : ASIA 3 PAL
MUA4P : AUS 4 PAL
2. Test Mode
2-1. Press "
Stop
" key and "
Display
" key at the same time with NO DISC condition.
2-2. Display "SYS 06830A" on the FL tube.
2-3. Press "
Display
" key three (3) times.
2-3. Display "0E-060907A" on the FL tube.
2-4. Press "
Display
" key two (2) times.
2-5. Press "
Standby
" bottom to exit the test mode.
3. Initializing
3-1. Press "
Stop
" key and "
Standby
" key at same time with No DISC condition.
Display "
INITIALIZE
" on the FL tube.
3-2. And display "COMPLETE" to "
STANDBY
".
(Version number of System MICIN)
(Version number of Back end MICIN)
TV MONITOR
Release Version : OE 060702A (HP-1-------)
FE Version : 10.26
BE Version : 1508530000
H: Writing of HDCP key OK
P: Writing of CPPM key OK
1: Region number
Light up all segment of FL tube.