SUGGESTED AIR LINE CONNECTION
Pitch pipe back toward air receiver
Compressor unit
Drain
Daily
Oil and Water Extractor should be at least 25 ft. from the compressor. Further if possible.
Drain Daily
Drain
Daily
Oil and Water
Extractor
Install drain at
each low point
PIPE SIZE, I.D. (Inches)
Air Flow
CFM
Length of Pipe (feet)
10
20
30
40
50
70
50
1/2"
3/4"
3/4"
1"
1"
1"
100
3/4"
3/4"
3/4"
1"
1"
1"
150
3/4"
3/4"
1"
1"
1"
1-1/4"
200
3/4"
1"
1"
1"
1-1/4"
The oil and water extractor should not be mounted on or near the air compressor.
The temperature of air is greatly increased during compression. As the air cools down to room
temperature, in the air line, on its way to the Air Power Tool, the moisture contained in it
condenses. Thus, for maximum effectiveness, the oil and water extractor should be mounted at
some point in the air supply system where the temperature of the compressed air in the line is
likely to be lowest. Air lines must be properly drained daily. Each low point in an air line acts as
a water trap. Such points should be fitted with an easily accessible drain. See diagram below.
Pitch all air lines back towards the compressor so that condensed moisture will flow back into
the air receiver where it can be drained off. Drain daily.
25 FEET OR MORE