14
Symptom
Cause
Remedy
Pump does
not operate
and motor
does not run.
No Electricity
Verify presence of electricity.
Not Plugged in correctly
Ensure pump is connected properly
Circuit breaker activated
Reset circuit breaker
Pump hums
and the
thermal relays
cut in and out
Pump is clogged by
debris
Clean suction pipe and foot valve/
strainer. Clean the pump by fl ushing
with water. Remove the priming and
drain plugs. If the pump cannot start
after several fl ushings, it must be
dismantled and cleaned.
Capacitor is defective
Replace Capacitor
Pump
operates but
delivers no
water.
Pump is not fi lled with
water.
Fill the pump with water (see
installation section - Priming Pump )
Suction head is too high
Reduce the suction head
Foot valve/strainer is not
submerged enough
Make the suction pipe longer (max 8
metres)
Suction pipe is taking
in air
Check the suction pipe and joints for
air leaks.
Suction pipe/strainer or
non-return valves are
clogged with debris
Clean the suction pipe/strainer or
non-return valve
Pump is clogged with
debris
Clean the pump of debris
Reduced
performance
Suction head is too high
Reduce suction head.
Foot valve/strainer only
partially submerged
Lengthen suction pipe.
Pump shaft seal is worn
or damaged
Replace defective parts
Pump is partially blocked
with debris
Remove debris and fl ush pump with
clean water
Pressure switch setting
are incorrectly set or
faulty.
Check and adjust pressure switch
and/or replace faulty parts.
Should problems persist, contact your nearest Onga Service Agent.