Ensure that this location is on a seperate footing from your home. To do this
you can mount the pump on a concrete tile or concrete base.
5. Power Source
Arrange for an electrician to install an outdoor 10A GPO electrical outlet near
the pump if there is not one there already.
6. Suction
This is the most important part of the installation as errors will cause signifi cant
problems for the system in performance and longevity.
IMPORTANT: A gate valve must be installed at the tank outlets.
Installations where the tank base is below the pump
Installations where the tank base is level with the pump
8
Min 100mm
100mm
In Line Filter
500 Micron
House W
a
ll
Recommended Length 150mm
Barrel Union
Solid Base
Min 100mm
100mm
In Line Filter
500 Micron
House W
a
ll
Recommended Length 150mm
Barrel Union
Solid Base
Non-Return
Valve
Gate
Valve
Gate
Valve
Summary of Contents for JMM100