We recommend, for additional protection, the pump 

to be supplied from socket outlet protected by a 

Residual Current Device – RCD (also known as 

an Earth Leakage Circuit Breaker – ELCB) with a 

maximum rated residual current of 30mA. 

Summary of Contents for JMM100

Page 1: ...vice before proceeding with the installation or operation of this product Jet Assisted Pumps 1000 Series JMM100 JS100 JSM100 JSK110 JS110 JSP110 JSK120 JS120 JSP120 We recommend for additional protection the pump to be supplied from socket outlet protected by a Residual Current Device RCD also known as an Earth Leakage Circuit Breaker ELCB with a maximum rated residual current of 30mA ...

Page 2: ...services Emergency services and Original Equipment Manufacturers Relax you ve bought an Congratulations on your decision to purchase an Onga product Onga is one of the best know brands in its field with a proud local and international reputation Onga is a brand for reliability value for money and technological innovation You will find Onga product wherever people need to move water in 3 broad market...

Page 3: ... do nothing short of that is acceptable Our commitment to quality is reinforced with our ISO 9001 2000 accreditation 3 A Fair Price Onga products are neither the cheapest nor the most expensive in their field Our products do on the other hand always represent very good value for money they always have and they always will 4 Our Team of Dealers The hand picked authorised Onga dealer network througho...

Page 4: ...3 Table of Contents Page Model Data 4 Application 5 Installation 6 Operation 11 Service and Maintenance 13 Troubleshooting 14 Warranty 17 ...

Page 5: ... Outlet Connection 1 BSP Male 1 BSP Female Power Supply 230V Voltage Limits 10 207 253V Impeller s Technopolymer Pump Case Polypropylene Stainless Steel Pump Shaft Stainless Steel Mechanical Seal Carbon Ceramic Motor TEFC IP44 Maximum Water Temp o C 40 50 Ambient Temp Range o C 1 50 ...

Page 6: ...umping clean water in a domestic water system small irrigation applications and general water transfer The Onga 1000 Series Jet Asssisted pumps are fantastic at self priming easy to install and come in a wide range of packages to suit almost any application ...

Page 7: ... installation and any subsequent service work The pump is designed to be used with clean water in a residential application Do not use it with alternative fluids abrasive corrosive or explosive fluids Do not install or operate your pump in an explosive environment or near combustible matter Incorrectly installed or tested equipment may fail causing severe injury or property damage Fire and burn haza...

Page 8: ...e to install this device may lead to product damage not covered by the manufacturers warranty 3 Pipe Installation Pumps can be damaged if care is not taken when connecting pipes Pipes should be supported so that the pump casing is not strained by the weight or misalignment We recommend the pump and pipe are coupled using flexible type polythene pipe rubber hose or a multi directional barrel union T...

Page 9: ...f the installation as errors will cause significant problems for the system in performance and longevity IMPORTANT A gate valve must be installed at the tank outlets Installations where the tank base is below the pump Installations where the tank base is level with the pump 8 Min 100mm 100mm In Line Filter 500 Micron House Wall Recommended Length 150mm Barrel Union Solid Base Min 100mm 100mm In Lin...

Page 10: ...ing at the top of the pressure controller 1 BSP Male to the household plumbing or garden taps If you want to test that the pump is operating correctly prior to having the plumbing connected attach a hose with a trigger nozzle to the top of the pressure controller 8 Pump Priming Ensure that there is at least 200mm of water in your tank i e that the tank outlet is covered and the pump will not draw ...

Page 11: ...on shall be separated again only for service purpose and only after the power supply is removed by unplugging the cord from the socket outlet The socket outlet shall be in a dry and flood free location preferably do not use extension cords for this very reason and because they can cause voltage drop Supply voltage outside limits specified in Model Data can cause motor overheat leading to overload tr...

Page 12: ...s debris or foreign matter to collect around the pump motor To avoid burns when handling the motor let it cool for at least 20 minutes before trying to work on it A thermal overload switch protects the motor for heat damage during operation DO NOT RUN PUMP DRY Ensure that your pump is filled with water before operating 1 Start up Operation Priming Prime the pump through the top priming plug port or...

Page 13: ...g on 20 40 psi should have a tank air charge of 18 psi Aqua Packs should be installed under cover out of the weather and the air pressure should be regularly maintained 4 Aqua Pack Tank Recharge Procedure The air charge should be checked at least once a year as tanks gradually lose air which causes pump cycling and pressure switch setting problems To check air pressure turn off the electricity to ...

Page 14: ...release pressure with care before servicing 1 General Care and Maintenance No lubrication or regular maintenance is needed beyond reasonable care When pump is not in use for a long period of time empty the pump rinse it with clean water and place it in dry storage In order to prevent possible failures it is advisable to periodically check the pressure supplied and power absorption A decrease in pr...

Page 15: ... Onga dealer for service There are leaks in the household plumbing Find and fix leaks No Water From Pump Pump is not primed Ensure that pump body and suction line are filled with water before starting Suction line is leaking Check the suction line for leaks especially at joints Blockages in the pump or discharge Disconnect the pump from the power outlet and check the pump housing and discharge for f...

Page 16: ...cessary Not enough air flow to cool motor Provide adequate ventilation to motor cooling fan Poor Performance low pressure or flow Suction line is leaking Check the suction line for leaks especially at joints Tank water level is too far below the pump Talk to your Onga dealer about a better pump for your situation or move the pump closer to tank Pump is worn or damaged Ask your Onga dealer to investi...

Page 17: ...16 Notes ...

Page 18: ...he warranty period then Pentair Water will at its sole option repair or replace the product with a like product Replacement product or parts may include re manufactured or refurbished parts or components How long the warranty is effective 1 This Pentair Water product is warranted for 24 months for all parts from the date of the first consumer purchase 2 Authorised workshop labour will be free of c...

Page 19: ...vice work will be denied or suspended on equipment not readily accessible to service personnel that is products that are behind barriers tiled or bricked in installed in roofs or second story external walls including inaccessible power points 4 Any service of any product which is found to be faulty due to abuse fair wear tear misuse or improper installation will be charged to the owner at the serv...

Page 20: ...l 64 9 579 6254 Fax 64 9 579 6497 Email auckland pentairwater com au Americas Pentair Inc www pentair com Europe Pentair Pumps S p A www Pentairpumps it Asia China www pentairwater com India www pentairwater com information contained here in remains the property of Pentair Water Pty Ltd Any reproduction display publication modification or distribution is strictly prohibited without the prior writte...