I. System Start-Up Information
O.A.S. 2002
c
2HP Commercial Wood Dust Collector Owners Manual
1. Read the installation and maintenance instructions as well as the recommended
safety practices in this manual.
2. Install Ductwork completely before operating collector:
A.) Seal ductwork with silicone sealant or duct tape.
B.) Have Dust Bin in place and sealed.
3. Have licensed electrician wire Fan / Blower according to wire diagram on pg. 14
in this owners manual.
4. Have licensed electrician check current draw on motor with all gates open. Current
draw should not exceed maximum motor amperage. (OAS is not responsible for
damage to motors caused by improper installation, wiring or failure to follow these
directions.)
Caution
The Direct Drive Fan / Blower makes the system top heavy!
Use extreme care when setting the unit up!
Warning
If amperage is too high - shut down immediately!
(See troubleshooting section.)
Warning
Do not operate Fan / Blower unless Cyclone and Dust Bin
are in place. Motor will over heat!
Warning
Check amperage draw during operation with all blast gates
open. Make certain amperage is not outside operating limit
indicated on motor plate!
2