XII. Fan / Blower Wiring Diagram
-
Leeson Motors
2hp Fan / Blower Wire Diagram - Single & Three Phase
Wiring should always be done by a licensed electrician!
2HP Cyclonic Wood Dust Collector Owners Manual
O.A.S. 2002
c
Before Operation
- Before making electrical power connections, check for proper grounding of motor and
application. All electrical contacts and connections must be properly insulated and enclosed. Coupling, belts,
chains or other mounted devices must be in proper alignment, balance and secure to insure safe motor operation.
Electrical Wiring
- Prior to connecting to the power line, check motorplate for proper voltage and rotation
connection. This motor should be installed in compliance with the National Electrical Code and any other applicable
codes. Voltage at motor not to or - 10% of nameplate voltage. Licensed electrician should make all
electrical connections.
P1
T2
T4
T5
Connect leads T1, T2, T3 to line.
To reverse rotation interchange any two power line leads.
Always use the wire diagram on the motor plate. Sometimes the wire diagrams on the motor will be for different
rotation. Wire for counter-clockwise rotation.
Single Phase
Low Voltage
115V
Line 1
Line 2
P2
T3
T8
Single Phase
High Voltage
208 - 230V
T4
T5
Line 1
Line 2
T2
T3
T8
P2
Tape
Three Phase
Low Voltage
208 - 230v
L1
L2
L3
T1 &
T2 &
T3 &
T7
T8
T9
T4
T5
T6
Connect
Three Phase
High Voltage
460V
L1
L2
L3
T1
T2
T3
T7
T8
T9
T4
T5
T6
Wire Nut
Tape &
Insulate
13
P1
Wire Nut
Tape &
Insulate
Ground: Connect house ground
wire to green chassis screw in
motor wire housing box.
Motor
Wire
Box
Green
Chassis
Screw
*** All motors should be grounded.
Lubrication
- Smaller frame size motors have permanantly lubricated bearings.
Inlet
Outlet
Outlet can be rotated and
oriented independent of inlet.
Counter-clockwise
if looking down
from the top.
***