background image

XIII.  Terms and Conditions

  Please look over the shipped order very carefully in the presence of the delivery person for damage or

incomplete shipment before signing the delivery receipt. Please note any tears or irregularities in shipping

packaging, however slight, on the shipping delivery receipt. This could be an indication of extensive concealed

damage. The shipping company will not take responsibility if the damage is not noted on the delivery receipt.

In the event of shipping damage, call O.A.S. immediately so we can expedite replacements. Please check

in all parts within 3 days from receiving order. Notify O.A.S. immediately of any missing or incorrect parts.

O.A.S. does not accept any claims for damage or shortage after 3 days from date of delivery.

Checking in Order

  Oneida Air Systems warrants products it manufactures for a period of 2 years to the original purchaser from

the date of purchase. Items not manufactured by O.A.S. are limited to their own manufacturer’s warranties.

This warranty does not apply to defects due directly or indirectly to misuse, negligence, accidents, abuse,

repairs, or alterations or lack of maintenance. This is Oneida Air Systems sole written warranty and any and

all warranties that may be implied by law, including any merchantability or fitness, for any particular purpose,

are hereby limited to the duration of this written warranty. O.A.S. does not warrant or represent that the

merchandise complies with the provisions of any law or acts unless the manufacturer so warrants. In no

event shall O.A.S.’s liability under this warranty exceed the purchase price paid for the product and any legal

actions brought against Oneida Air Systems shall be tried in the State of New York, County of Onondaga.

  Oneida Air Systems shall in no event be liable for death, injuries to persons or property or for incidental,

contingent, special, or consequential damages arising from the use of our product.

  Oneida Air Systems does not warrant or authorize use of wood dust collectors for other purposes. This

includes wood products that are treated, coated, or otherwise altered from their natural state.

Limited Warranty

  Products will be shipped to Buyer’s single destination. Title and risk of loss shall pass to the Buyer upon

delivery to such destination. Buyer pays transportation expenses. Dates of shipment are advisory and O.A.S.

will make reasonable efforts to ship on or before the date states for shipment, however, O.A.S. shall not incur

any liability for failure to ship on that date.

Delivery Risk of Loss

  Buyer must inform O.A.S. of any shortage or damage, by so noting in writing, on the freight delivery bill prior

to signing to indicate receipt of shipment. All claims, including claims covered under the limited warranty, are

subject to inspection and investigation by O.A.S.. O.A.S. reserves the right to inspect and investigate all

returned products before Buyer’s claim is settled. All products returned for a cash refund must be unused,

resaleable and purchased within the last six months. There are no refunds on flex hose or custom made

components. 

There will be a 25% restocking fee applied to any returned items.

Returned Goods Policy

O.A.S. 2005

c

3HP High Pressure Owner’s Manual

14

*Note: Motors should be protected from extreme weather to prolong motor life.

Single phase motors should only be started and stopped up to 4 - 10 times per

hour. Starting single phase motors more frequently can cause heat build up

and can cause the motor overload to trip or cause motor damage. In general,

motors should be started and stopped as little as possible for maximum

lifespan and best economy (electrical use).

Summary of Contents for 2005c3HP

Page 1: ...3HP High Vacuum Dust Collector Oneida Air Systems Inc 1001 West Fayette St Syracuse N Y 13204 Phone 1 800 732 4065 315 476 5151 Fax 315 476 5044 www oneida air com Owner s Manual...

Page 2: ...t Table of Contents Page Read the entire Owner s Manual before installing or operating system I II III IV V VI VII VIII IX X XI XII XIII XIV 2 3 4 5 6 7 8 8 9 10 11 12 13 14 15 System Start Up Informa...

Page 3: ...Caution The Dust Collector Fan Blower is heavy Handling and installation should always be performed by experienced and trained personnel who have experience with rotary equipment In addition to the f...

Page 4: ...Vacuum Owner s Manual 3 Pleated Cartridge Filters Do not remove fabric straps from cartridge Removable Dust Container Removable 55 Gal Metal Chip Dust Bin 3hp Integral Fan Blower Angle Iron Stand Fle...

Page 5: ...Spun Bonded polyester BIA ZH1 487 test Rated C Captures 99 99 of test material over 20 microns Captures 99 9 of test material between 0 2 2 0 microns 11fpm External Cartridge Filter 55 Gal Steel Drums...

Page 6: ...2 7 1 4 36 75 3 4 111 7 8 12 62 30 7 8 10 031 I D 7 64 I D 1 25 Flange For Minimum Mounting Heights with 55 gal drum 26 1 8 O D of Mounting Ring Bolt Holes 24 7 8 18 56 Outlet Size 56 7 3 4 14 1 8 18...

Page 7: ...cuum Owner s Manual V Angle Iron Stand Bolt together the stand using the cross bars and 3 8 x 1 bolts Note the cross bar on the cyclone stand goes in the back so that the dust bin can slide out 55 Gal...

Page 8: ...gral Fan Blower Angle Iron Stand Outlet Inlet Elbow Square to Round Cone Cyclone Clamp Ring VI Assembly Instructions Cyclone Barrel Air Inlet Fan Blower 1 1 Orient the blower housing to match the stan...

Page 9: ...ground per local and national codes Consult a licensed electrician with questions or if repairs are required Electrical Connections A All wiring fusing and grounding must comply with National Electri...

Page 10: ...tom dust pan before or during the blow off process Let dust settle into dust pan Unclip and dump out dust Filter removal is not required You can also run your fingers around the filter pleats to knock...

Page 11: ...tor 230v 14 5 amps TEFC Wiring should always be done by a licensed electrician Ground Connect house ground wire to green chassis screw in motor wire housing box Motor Wire Box Green Chassis Screw Top...

Page 12: ...must be used OAS offers Square D Full Voltage Non Reversing across the Line Starters Nema Type 1 Enclosure with Start Stop in cover and class 10 overload Industrial switches can also be purchased thro...

Page 13: ...ort or too small a branch line See branch line diameter chart in ductwork guide Be sure that your filter is clean See filter cleaning directions Filter Clogging Caused By Air leakage between cyclone a...

Page 14: ...below 420 microns in size 017 of an inch in certain concentration ranges when ignited can deflagrate burn quickly An ignition source such as a spark or ember can ignite a dust mixture resulting in an...

Page 15: ...York County of Onondaga Oneida Air Systems shall in no event be liable for death injuries to persons or property or for incidental contingent special or consequential damages arising from the use of o...

Page 16: ...3HP High Pressure Owner s Manual 15...

Reviews: