Configuration attributes
Crocus CNV
84
Reference manual
crocusIfConv<2m/Nx64><Tt/Cv>/Cold Boot
This action will reboot the Crocus CNV while the power stays up (the Crocus CNV also reboots if it is
powered down and up again).
This implies that:
•
it checks which firmware to use
•
it reads the saved configuration and restarts program execution.
You can use this action, for instance, to activate new firmware.
To perform a cold boot, proceed as follows:
Step Action
1
In the TMA window, select the top object
crocusIfConv<2m/Nx64><Tt/Cv>
and the group
Configuration, Status, Performance
or
Alarms
.
2
In the action window of TMA, click the left mouse button on
Cold Boot
so that this action is
selected.
3
Press the right mouse button and select
Execute
.
⇒
The session between TMA and the Crocus CNV is interrupted.
4
Re-establish a TMA session on the Crocus CNV.
⇒
The Crocus CNV attributes reappear on your screen.
If a
Cold Boot
is performed on a Crocus CNV CV, both converter A and B reboot.