Crocus CNV
Status attributes
Reference manual
101
7.3 G703 onboard status attributes
crocusIfConv<2m/Nx64><Tt/Cv>/g703OnBoard/testType
This attribute displays which interface test is currently active on the onboard G703 interface. The possible
indications are:
Value Description
no
No test is active.
al
An Analogue Loop is active.
dl
A Digital Loop is active.
rdl
A Remote Digital Loop is active.
et
An Error Test is active.
alEt
A combination of an Analogue Loop and an Error Test is active.
rdlEt
A combination of a Remote Digital Loop and an Error Test is active.
For more information on these tests, refer to Chapter
11.5 - Diagnostic tests
.
crocusIfConv<2m/Nx64><Tt/Cv>/g703OnBoard/testOriginator
This attribute displays the origin of the active test. The possible indications are:
Value Description
nms
The test is initiated by the Total Maintenance Application or a central management
system (e.g. TMA under HP OpenView
®
).
keyboard
The test is initiated by means of the buttons on the front panel of the Crocus CNV.
interface
The test is initiated by the application, via the interface.
remote
The test is initiated by the remote Crocus CNV.
unknown
There are two possibilities:
•
No test is running.
•
For some reason it is not possible to define the origin of the test.
Summary of Contents for Crocus CNV
Page 1: ...Crocus CNV Crocus CNV USER and REFERENCE MANUAL Version 1 5 500866...
Page 10: ......
Page 11: ...Crocus CNV User manual 1 User manual...
Page 12: ...Crocus CNV 2 User manual...
Page 84: ...Crocus CNV 74 Reference manual Reference manual...
Page 85: ...Crocus CNV Reference manual 75...
Page 136: ...Alarm attributes Crocus CNV 126 Reference manual...
Page 165: ...Crocus CNV Annexes 155 Annexes...
Page 166: ...Crocus CNV 156 Annexes...
Page 168: ...Annex A product information Crocus CNV 158 Annexes...