ONE
™
Cartridge Tank Filters
Page 1: ...ONE Cartridge Tank Filters ...
Page 2: ...cement Parts 12 Installation Fitting Assemblies 13 14 Warranty 15 Your ONE cartridge tank filters are precision built high quality products These units will deliver filtered water for many years to come when installed and operated properly Please study this manual carefully and understand the cautions and notes before installing This manual should be kept for future reference If you have any quest...
Page 3: ... four positions including a diagnostic position that allows a service technician to have pressure to test a system while still providing untreated water to the building Be sure to install bypass valve onto the head assembly before beginning plumbing Or make provisions in the plumbing system for a bypass The bypass body and rotors are glass filled Noryl and the nuts and caps are glass filled polypr...
Page 4: ...lding The water treatment system will depressurize upon opening a tap in the building If water is available on the outlet side of the filter it is an indication of water bypassing the system Fig 4 i e a plumbing cross connection somewhere in the building NORMAL OPERATION POSITION Figure 1 DIAGNOSTIC POSITION Figure 3 BYPASS POSITION Figure 2 SHUT OFF POSITION Figure 4 ...
Page 5: ...des These bypass valves should allow for water to be turned off to the filter tank for future cartridge replacement and allow for system bypassing should other service be required BYPASS INSTALLATION FOR EF 835 2 NOTE Drain should be considered in plumbing of system as per diagram Opening drain valve will allow for flushing of cartridge Closing inlet and outlet valve and opening drain will relieve...
Page 6: ... Wrench CV3193 02 If necessary pliers can be used to unscrew the nut or cap Do not use a pipe wrench to tighten nuts or caps Do not place screwdriver in slots on caps and or tap with a hammer SITE REQUIREMENTS water pressure 25 100 psi water temperature 33 100 F 0 5 37 7 C the tank should be on a firm level surface 1 This unit is equipped with a 1 25 CPVC connection at the bottom of the tank This ...
Page 7: ...odes 6 INSTALLING GROUND To maintain an electrical ground in metal plumbing of a home s cold water piping such as a copper plumbing system install a ground clamp or jumper wiring NOTE If replacing an existing filter also replace the ground clamps wire 7 DRAIN LINE First be sure that the drain can handle the rinse rate of the system At the bottom of the tank is a 1 25 CPVC socket to accommodate a d...
Page 8: ...8 ...
Page 9: ...rotect area from water damage 7 Remove new cartridge filter from box and remove plastic covering Locate product description tag and keep for future use 8 Lubricate O ring on adaptor to ensure proper sealing Do not use pipe dope Vaseline oils or other unacceptable lubricants on O rings Food grade silicone lubricant is recommended 9 Place cartridge into filter housing with adaptor stub at the top of...
Page 10: ...m for placement of retaining ring in ring groove 9 Insert retaining ring into ring groove starting at the end opposite of the handle Using only hands gently push retaining ring into groove until entire ring is in place and both ends meet in groove section see photo to right 10 To ensure proper engagement hold retaining ring by handle and slightly rotate around inner diameter of vessel 11 Slowly tu...
Page 11: ...size or use multiple tanks B Very heavy loading B Check raw water for particles C Excessive water flow through cartridge C Check gallons consumed Plugged drain A Not flushed often enough A Flush more frequently Water leak at depressurization button EF 835 2 only A O ring leak A Replace depressurization button PROBLEM CAUSE CORRECTION REPLACEMENT CARTRIDGES EF 835 1 REPLACEMENT CARTRIDGES Part No D...
Page 12: ...s 2 7 Z008840XBK00 8 x 40 vessel shell w base 1 8 CT 2 5ADAPTER Adapter tee for 2 5 opening 1 EF 835 2 REPLACEMENT PARTS Item No Part No Description Qty 1 CT RETAINGRING Retaining ring for top and bottom 2 2 CT 1 4NPTLID Top cap with pressure release 1 3 R ORING LID O ring replacement for all lids caps 2 4 Z008840XBK00 8 x 40 vessel shell w base 1 5 CT 4 5LID Threaded top and bottom commercial cap...
Page 13: ...2 1 brass sweat assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3188 Fitting 2 3 4 BRASS SWEAT Item No Part No Description Qty CV3007 03 3 4 brass sweat assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3188 01 Fitting 2 1 PLASTIC MALE NPT Item No Part No Description Qty CV3007 04 1 plastic male NPT assembly 2 1 CV31...
Page 14: ...V3375 Fitting 2 1 BRASS SHARK BITE Item No Part No Description Qty CV3007 13 1 brass Shark Bite assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3629 Fitting 2 3 4 BRASS SHARK BITE Item No Part No Description Qty CV3007 12 3 4 brass Shark Bite assembly 2 1 CV3151 Nut 1 quick connect 2 2 CV3150 Split ring 2 3 CV3105 O ring 215 2 4 CV3628 Fitting 2 3 4 JOHN G...
Page 15: ...t in effect until installer performs product specific ENPRESS LLC Product Protocol when required for testing record keeping and certification of the ONE product prior to installation 9 THIS WARRANTY EXCLUDES THE FOLLOWING a Damage caused by improper installation operation or care b Damage caused by chemical attack environment accident fire flood freezing Act of God misuse misapplication neglect ox...