background image

©

 Semiconductor Components Industries, LLC, 2011

August, 2011 

 Rev. 3

1

Publication Order Number:

EVBUM2015/D

NCP370GEVB

NCP370 Over Voltage
Protection Controller with
Reverse Charge Control
Evaluation Board User's
Manual

Description

The NCP370 is an overvoltage, overcurrent and reverse control

device. Two main modes are available by setting logic pins.

First mode is Direct Mode from Wall Adapter to the system. In this

mode the system is both positive and negative overvoltage protected
up to +28 V and down to 

28 V. The wall adapter is disconnected from

the system if the input voltage exceeds the overvoltage (OVLO) or
undervoltage (UVLO) thresholds. At powerup, the Vout turns on
30 ms after the Vin exceeds the undervoltage threshold.

The second mode, called the Reverse Mode, allows an external

accessory to be powered by the system battery or a boost converter.
Here, the external accessory would be connected to the device input
(bottom connector of system) and the device battery would be at the
device output. In this case, overcurrent protection is activated to
prevent accessory faults and battery discharge. Thanks to the NCP370
using an internal NMOS, the system cost and the PCB area of the
application board are minimized. The NCP370 provides a negative
going flag (FLAG(BAR)) output which alerts the system that a fault
has occurred. In addition, the device has ESD protected input (15 kV
Air) when bypassed with a 1.0 

m

F or larger capacitor.

Figure 1. NCP370GEVB Board Picture

http://onsemi.com

EVAL BOARD USER’S MANUAL

Summary of Contents for NCP370GEVB

Page 1: ...the Vout turns on 30 ms after the Vin exceeds the undervoltage threshold The second mode called the Reverse Mode allows an external accessory to be powered by the system battery or a boost converter...

Page 2: ...NCP370GEVB http onsemi com 2 Figure 2 NCP370GEVB Board Schematic...

Page 3: ...Molex WM17118 ND 4 pins USB A 1 FLAG rohm 511 1287 ND Green LED 0805 1 R6 susumu Rr08p value dct nd 1 kW CMS0603 0 5 2 R3 R4 susumu Rr08p value dct nd 100 kW CMS0603 0 5 Not mounted R5 R7 R8 R9 USB d...

Page 4: ...NCP370GEVB http onsemi com 4 PCB Figure 3 NCP370GEVB Board Layout Top View Figure 4 NCP370GEVB Board Layout Bottom View...

Page 5: ...5 CONNECTING PROCESS 1 Place REV strap and DIR strap on left side 1 logic connected to Vbat through pull up resistor 2 Let Battery strap opened 3 Connect a Battery or power supply 4 2 V on Battery tes...

Page 6: ...NCP370GEVB http onsemi com 6 4 Connect strap on lim ILIM PIN 7 SW2 2 R2 14k R1 70k SW1 IMAX...

Page 7: ...it threshold with pull down resistors connected on pin 7 SW1 SW2 IOCP 0 0 500 mA 0 1 1 A 1 0 1 5 A 1 1 1 5 A R1 70K R2 14K Disable Mode 6 Connect 10 V capability Vin Supply on IN1 test point a Set pow...

Page 8: ...ft to right 1 logic level to 0 logic level 8 Check Vout 5 V and Flag LED is still off 9 Set Vin 7 V 10 Check Flag LED on and Vout is 0 V 11 Switch REV from left to right 1 logic level to 0 logic level...

Page 9: ...as components in systems intended for surgical implant into the body or other applications intended to support or sustain life or for any other application in which the failure of the SCILLC product c...