background image

FUSB302GEVB

www.onsemi.com

4

Figure 3. FUSB302 EVB FM150702B Schematic (2/2)

Summary of Contents for FUSB302 Type-C

Page 1: ...or a Type C plug with a fixed CC and VCONN channel Full Type C 1 3 support Integrates the following functionality of the CC pin Attach detach detection as source Current capability indication as sourc...

Page 2: ...This capacitance is C6 and C7 in the schematic VBUS VBUS is used differently based on the Type C port type As a sink port VBUS is directly connected to the Type C receptacle J1 and the VBUS test poin...

Page 3: ...FUSB302GEVB www onsemi com 3 SCHEMATIC Figure 2 FUSB302 EVB FM150702B Schematic 1 2...

Page 4: ...FUSB302GEVB www onsemi com 4 Figure 3 FUSB302 EVB FM150702B Schematic 2 2...

Page 5: ...ates Disconnected then there is a connection problem Upgrading the GUI Software 1 Simply delete the previous version of the exe 2 Repeat the installation process above GUI OPERATION Program Startup To...

Page 6: ...Device Control Tabs Tabs provide detailed control and monitoring of the FUSB302 The sections below describe how to use these controls General USB The General USB tab implements functional Type C state...

Page 7: ...ackets The other control boxes indicate the current state of the PD state machine and what contract was negotiated When connected as a sink it displays the source capabilities of the source that is at...

Page 8: ...esolution To stop logging click the Auto Poll option in the Preferences menu An example of a Type C attach and the PD communication flow is shown below To support debug efforts the Set State button ca...

Page 9: ...pond once a connection is made It is the programmed source and sink capabilities of the device and the charging algorithm that is used to automatically select a source capability when connected to a s...

Page 10: ...on tells the GUI to automatically check the DEVICE_ID register for the I2C address selected in the Addr pull down box and display the Device Connected or No Device message in the lower left corner of...

Page 11: ...g from 3 consecutive registers r 0 0x42 3 0x04 read 3 bytes starting at MEASURE register address 0x04 An example of writing to 2 consecutive registers w 0 0x42 2 0x0E 0x22 0x55 write 2 bytes starting...

Page 12: ...the EVB Right clicking on the Sop field allows you to add SVIDs Right clicking on an SVID allows you to remove the SVID or add a Mode Right clicking on a Mode allows you to remove it Retrieving VDM i...

Page 13: ...ems or any FDA Class 3 medical devices or medical devices with a similar or equivalent classification in a foreign jurisdiction or any devices intended for implantation in the human body Should you pu...