LIBRETTO ISTRUZIONI - INSTRUCTION MANUAL
23
EN
14
AUTOMATIC PROGRAMMING:
WARNING before of the programming is necessary testing the opening directon.The fist working after the command START must be
opening , if working in close direction reverse the wires motor ( 13 and 15) and the wires limit switch (9 and 10)
PROCEDURE FOR PROGRAMMING THE STROKE ( with the setting 20cm space slowing down in opening and 40cm space
slowing down in closing):
A-
Completely close the gate
. Press and hold
button SET until the gate start in opening direc-
tion (start of the automatic programming mode)
B- The gate stop in the open position and clo-
sing
C- The gate closing, with 40cm of slowing down
before the limit switch.
FINECORSA APERTURA
LIMIT SWITCH OPENING
SEQ
DL2
SET
X10SEC.
OPEN
15
PROGRAMMING THE REMOTE CONTROLS
:
The control panel can be programmed with a max of 8 remote controls fix or rolling code.
15.1-
PROGRAMMING THE REMOTE CONTROL ASSOCIATED WITH THE START INPUT
A- press button SET TX the LED DL2 starts flashing
B- press the button on the remote control to be programmed with the START command within 10 sec.
D- LED DL2 stop flashing
A- press 2 times button SET TX the LED DL2 with 2 flashes cyclic
B- press the button on the remote control to be programmed with the PEDESTRIAN command within 10 sec-
onds
D- LED DL2 stop flashing
15.2-
PROGRAMMING THE REMOTE CONTROL ASSOCIATED WITH THE PEDESTRIAN INPUT:
15.3-
DELETE ALL THE REMOTE CONTROL:
press and hold button SET TX for 10 seconds ( the LED DL2 flashing). After 10 seconds the led DL2 is OFF.
SET TX
DL2
DL2
SET TX
DL2
DL9