CHANGE THE HEIGHT UNIT

   

(inches or centimeters)

 

 

The handswitch can display the table height in either centimeters or inches. With the help of the  
S5-menus, the unit of measure can be changed. 

To change the unit of measure, follow these steps: 
1. Press and hold the 1, 2, and UP buttons until the display shows “S 5”. 

2. Confirm by pressing the “S” button. Now the display will have changed.

To exit the menu without making a selection, wait until the height display appears again.

CHANGE THE HEIGHT DISPLAY 

If the displayed value does not match the actual height of the table top, the display can be corrected  
as follows: 
1. Press and release the “S” button. 

2. Press and hold the DOWN button until the display starts to flash.

 

3. Change the height shown on the handswitch by pressing the UP or DOWN button to the desired height.  

Confirm by pressing the “S” button.

To exit the menu without making a selection, wait until the height display appears again.

SAVE MEMORY POSITION 

 

1. Move the table up or down to the desired height.  
2. Press the “S” button (in the display “S -” is shown.)  
3. Select a position by pressing one of the four number buttons, 1-4, (the display will show the setting  
as “S1”).  

4. The saved position is confirmed by a double click sound from the control box. The display shows the 

current table height. Repeat steps to save a maximum of four different positions.

RECALL MEMORY POSITION

  

Press and hold the desired memory button (1, 2, 3 or 4) the table moves from the current position into 
the saved position. The button must be pressed until the position is reached. If the button is released, 
the table will stop short of the desired height.

OPERATION INFORMATION

Summary of Contents for OV1022 118101

Page 1: ...USER GUIDE OV1022 Part No 118101 OV1022 HEIGHT ADJUSTABLE TABLE...

Page 2: ...User Guide OV1022 OV1022 HEIGHT ADJUSTABLE TABLE FEATURES Full table base add your own work surface Over 150 color options Rated at 225 lb load per two column kit Integrated wire management PRODUCT O...

Page 3: ...eration 13 Change the Height Unit 14 Adjust Height Display 14 Save Memory Position 14 Recall Memory Position 14 Troubleshooting 15 16 Unit Errors 15 Handswitch Errors 16 Technical Data 17 Standards Ce...

Page 4: ...3 7 8 9 6 5 4 2 10 PARTS Qty Package 1 Column 2 2 Leg 2 3 Glide 4 4 1 Piece J Rail with Cable Tray 1 5 M6x12mm Screw 16 6 Top Support 2 7 Programmable Handswitch 1 8 Power Cord 1 9 Control Box 1 10 M8...

Page 5: ...2 11 PARTS Qty Package 1 Column 2 2 Leg 2 3 Glide 4 4 3 Piece Adjustable J Rail with Cable Tray 1 5 M6x12mm Screw 20 6 M6 Wing Nut 4 7 Top Support 2 8 Programmable Handswitch 1 9 Power Cord 1 10 Contr...

Page 6: ...T Body parts and property can be caught between the moving work surface and an immobile obstacle such as shelves furniture window sills or walls Keep at least one inch of clearance around desk and mak...

Page 7: ...able legs If your table needs service contact customer service Never operate this workstation if it has a damaged cord or plug KEEP TABLE FRAME DRY Keep all electrical components away from water and h...

Page 8: ...semble the top support to the column 2 Assemble the column to the j rail 3 Assemble the leg to the column 4 Fasten the table frame onto the table top 5 Fasten the control box and handswitch to the tab...

Page 9: ...AIL Assemble using the M6x12mm length screws 2 per column The maximum tightening torque for these screws is 9 9Nm 7 3 ft lbs 2 ASSEMBLE THE TOP SUPPORT TO THE COLUMN Assemble using the M6x12mm length...

Page 10: ...7 ft lbs 3 PRE INSTALL THE HEX NUTS Partially install the M8 hex nuts onto column studs about halfway INSTALL LEG OVER THE HEX NUTS Using keyhole openings install the leg over the hex nuts and slide...

Page 11: ...FRONT working side CONNECT THE MOTOR CABLES TO THE CONTROL BOX The motor cable plug connection has to click into place Connections to the control box M1 M2 Connectors for the columns HS Connectors fo...

Page 12: ...TO THE CONTROL BOX 7 CONNECT THE SUPPLIED POWER CORD AC TO THE CONTROL BOX ATTACH ALL CABLES TO THE TABLE TOP AND OR PLACE IN CABLE TRAY Attach cables in order to avoid any damage during operation Nev...

Page 13: ...travel limits Under no circumstance should a control box from one table be moved to another NORMAL HANDSWITCH OPERATION for all handswitch types By pressing the UP or DOWN buttons the table will move...

Page 14: ...display starts to flash 3 Change the height shown on the handswitch by pressing the UP or DOWN button to the desired height Confirm by pressing the S button To exit the menu without making a selectio...

Page 15: ...p Replace the handswitch Max time limit is exceeded Control is activated automatically after approx 9 minutes Defective drive Contact customer service Defective control box Contact customer service De...

Page 16: ...problem still exists please contact customer service If necessary reduce the load on the table Reset the table see page 13 Option ISP function Remove source M2 Overcurrent M3 Overcurrent Collision re...

Page 17: ...m input current 5 A Standby power consumption primarily 0 3 W Operating temperature 0 35 C Protection class IP 20 Maximum duty cycle 5 1 min on 18 min off Maximum power output rated 240 watts TWO COLU...

Page 18: ...NTATIVE FOR WARRANTY INFORMATION WARRANTY The drive system is tested according to the following standards Meets BIFMA X5 5 2014 CUSTOMER SERVICE End of life cycle Once product is disassembled all stee...

Page 19: ...OV1022 USER GUIDE Part No 118101 Rev A Rev 022020...

Reviews: