Setting the Output Conditions
ZW User's Manual
317
Senso
r con
trol
ler ope
ra
ti
ons
9
Performing Thickness Scaling
Performing Thickness Scaling p.92
Operating procedure
Steps
Key operation
Display
Description
1 to 5
For moving to "SCALE", see steps 1 to 5 in p.314.
6
Select "THICK" as the scaling type.
The current setting value is displayed on the sub-display.
Press
/
key to enter editing mode and the sub-display blinks.
Select "THICK" and press the
key.
7
The current measured value is displayed on the main display and the
current setting value is displayed on the sub-display.
Press
key to enter the editing mode, and the sub-display
blinks.
To edit numerical values, use the
/
/
/
keys.
Enter the setting value and then press the
key.
8
"OK/CAN" is displayed on the sub-display.
Press the
key to execute scaling or
key to cancel.
9
Press the
key for two seconds to enter the RUN mode.