background image

Io

n

iza
tion

 ti

m

e

 (s)

Io

n

iza
tion

 ti

m

e

 (s)

Relationship of Air Pressure and Installation 
Distance to Ionization Time

Bar Length vs. Air Pressure and Airflow

350

300

250

200

150

100

50

0

0.05

0.1

0.2

0.3

A

ir

flo

w (
L

/m

in

 n

o

r)

-400

-300

-200

-100

0

100

200

300

400

Ionization Time for Each Ionization Area

With installation distance of 50 mm (reference value)

Ionization area (mm)

Model: ZJ-BAS050
Installation distance: 50 mm
Air pressure: 0.3 MPa
Frequency: 10 Hz
Charge plate monitor: 150 mm X 150 mm, 20 pF
Ionization time: ±1,000 V to ±100 V

Measuring conditions:

0

5

10

15

20

50

100

200

300

600

1000

1500

0.05 MPa

0.1 MPa

BAS050

BAS058

BAS074

BAS090

BAS130

BAS154

0.2 MPa

0.3 MPa

Installation distance (mm)

Air pressure (Mpa)

0

0.2

0.4

0.6

0.8

1

Ioni

za
tion

 time

 (

s

)

With installation distance of 1,500 mm (reference value)

Ionization area (mm)

Model: ZJ-BAS050
Installation distance: 1,500 mm
Air pressure: 0.3 MPa
Frequency: 10 Hz
Charge plate monitor: 150 mm X 150 mm, 20 pF
Ionization time: ±1,000 V to ±100 V

Measuring conditions:

-400

-300

-200

-100

0

100

200

300

400

2

4

6

8

10

8

Engineering Data

Product Configuration

ZJ-BAS

Linking Bracket Set

ZJ9-BAS-L01

AC Adapter

ZJ-BAS-PS01

Power supply cable

Select from the two available types.

Used when using an AC adapter.

Used when using a DC power supply.

The length of the cables that can be linked depends on the number of Ionizers to be linked together. 

Contact your OMRON sales representative for details.

Cable with Connectors on Both Ends

ZJ-BAS-MC

@@

B

Cable with Connector on One End

ZJ-BAS-MC

@@

A

ZJ-BAS-MC

@@

RB

 Power Supply Cable

 (for linking Ionizers) 

Ionizer

Special Remote 
Control

Remote Control

ZJ-BAS-R01

Remote Control Receiver

ZJ-BAS-R02

I/O Cable

Used for 
connecting 
external devices.

ZJ-BAS-FC

When Linking Ionizers

EXIT

Enter

UP

DOWN

Summary of Contents for ZJ-BAS Series

Page 1: ...Effective and Efficient Ionization N E W Digital Bar Ionizer ZJ BAS...

Page 2: ...The highest level of ionization in its class Industry First Ionizes areas wider than the Ionizer itself Wide Area Achieves the highest level of short distance ionization in its class Short Distance S...

Page 3: ...niform Airflow Uniform Ion Balance A New Proposal for Effective and Efficient Ionization Ion Sensing and variable AC system prevents ion recombination Because the ZJ BAS Ionizer uses a method in which...

Page 4: ...OD 6XSSRUWV 6DIH 5HOLDEOH 6HWWLQJV 4HE CHARGED STATE IS DISPLAYED USING COLORS 3ET 6ALUE ISPLAY LEANING ISPLAY OTIFIES WHEN CLEANING IS REQUIRED PERATION 3TOP ODE 4HE LAMP WILL FLASH TO INDICATE THAT...

Page 5: ...UCTURE LOW CURRENT CONSUMPTION THAT IS ENVIRONMENTALLY FRIENDLY FFECTIVE LENGTH MM UMBER OF ISCHARGE ODULES LAPSED TIME HOURS 3 INITIAL STATUS 0REVIOUS MODEL INITIAL STATUS ONIZATION TIME S 0REVIOUS M...

Page 6: ...m reference value Ionization area mm Model ZJ BAS050 Installation distance 1 500 mm Air pressure 0 3 MPa Frequency 10 Hz Charge plate monitor 150 mm X 150 mm 20 pF Ionization time 1 000 V to 100 V Mea...

Page 7: ...J BAS MC20A ZJ BAS MC02B ZJ BAS MC05B ZJ BAS MC10B ZJ BAS MC15B ZJ BAS MC20B ZJ BAS MC07RB ZJ BAS MC08RB ZJ BAS MC09RB ZJ BAS MC11RB ZJ BAS MC15RB ZJ BAS MC17RB Quantity Appearance Set of 5 Set of 10...

Page 8: ...J BAS154 1410 1540 Approx 0 58 kg Approx 0 64 kg Approx 0 8 kg Two mounting brackets two M4 screws instruction manual Two mounting brackets two M4 screws 1 medium bracket instruction manual Approx 0 9...

Page 9: ...BAS MC B MC RB 25 6 43 5 39 5 20 60 175 27 70 8 12 22 5 50 9 L L 2m 5m 10m 15m 20m 4 dia 4 5 dia L 45 10 8 25 7 5 L 2 m 5 m 10 m 15 m 20 m 33 37 19 30 14 37 2 27 15 Two 3 2 dia 15 4 4 3 75 2 16 10 85...

Page 10: ...Regional Headquarters OMRON EUROPE B V Sensor Business Unit Carl Benz Str 4 D 71154 Nufringen Germany Tel 49 7032 811 0 Fax 49 7032 811 199 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg IL 60173...

Reviews: