2
3
Ion Sensing and Variable-AC System
An ion sensor installed on the
bottom of the Ionizer detects the
charge and ion balance.
The applied voltage is flexibly
controlled according to the ion
balance conditions to raise
ionization efficiency.
Technology 1
High-speed airflow is achieved by
minimizing the air nozzle
diameter. An optimal cone shape
is also employed for the inside of
the nozzle to further improve ion
dispersion. By using a special ring
guard shape to pull passive
(external) air into the active air
stream, the total airflow is
dramatically increased.
Micro Power Spraying (MPS) Structure
Technology 2
Narrow
80 mm
lZJ-BAS
lPrevious Models
Setting the discharge electrodes at
a pitch that is 80 mm longer than in
our previous models achieves an
optimal layout that unifies ionizing
performance and reduces ion
recombination. This model ionizes
over long distances with or without
the use of an Air Purge Ionizer.
ALARM
Optimized Discharge Electrode Pitch Optimized Discharge Electrode Pitch
Technology 3
The highest level of ionization in its class.
Industry
First
Ionizes areas wider than the
Ionizer itself.
Wide Area
Achieves the highest level
of short-distance
ionization in its class.
Short
Distance
Steady ionizing performance,
even over long distances.
Long
Distance
Applied voltage is varied.
Active air
Ion generation
A large amount of ion
recombination.
Wide
The larger pitch causes
uneven ion discharge.
A small amount of ion recombination.
Passive air is
pulled in.
Ring guard
Io
ni
za
tion
t
ime
(
s)
-400
-300
-200
-100
0
100
200
300
400
Horizontal positioning (mm)
0.1 s
Measurement conditions:
ZJ-BAS058
Frequency setting: 20 Hz
Air pressure: 0.3 Mpa
Charge plate monitor: 150 mm X 150 mm, 20 pF
Ionization time: ±1,000 V to ±100 V
0
1
2
3
4
5
lInstallation distance: 50 mm
Io
niz
at
io
n t
im
e (
s)
-400
-300
-200
-100
0
100
200
300
400
Horizontal positioning (mm)
4.0 s
Measurement conditions:
ZJ-BAS058
Frequency setting: 20 Hz
Air pressure 0.3 Mpa
Charge plate monitor: 150 mm X 150 mm, 20 pF
Ionization time: ±1,000 V to ±100 V
0
10
20
30
40
50
l Installation distance: 1,500 mm
Ionizes a wide area
Advanced Features
in 3 Aspects
Three Technologies Supporting
Effective and Efficient Ionization
Ionizer length
Effective and Efficient Ionization