F-110
Enclosed Switch
ZC-
@55
Terminal Protective Cover, Seal Rubber, and Rubber Packing
(The Switch is equipped with these 3 items as a standard.)
Specifications
■
Approved Standards
(Except Molded Terminal Models and Operation Indicator-equipped Model)
■
Approved Standard Ratings
UL/CSA
A300
TÜV Rheinland
250 V, 10 A (AC12)
■
Ratings
Note: 1.
The above figures are for steady-state currents.
2.
Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3.
Lamp load has an inrush current of 10 times the steady-state current.
4.
Motor load has an inrush current of 6 times the steady-state current.
5.
The above ratings were tested under the following conditions according to JIS C4508.
Ambient temperature:
20
±
2
°
C
Ambient humidity:
65
±
5%
Operating frequency:
20 operations/min
Agency
Standard
File No.
UL
UL508
E76675
CSA
C22.2, No. 14
LR45258
TÜV Rheinland
EN60947-1, EN60947-5-1
J9650089
Rubber packing
Terminal cover
Seal rubber
•
ZC Terminal Cover
(Product code: ZC55-0002H)
•
ZC Seal Rubber
(Product code: SC-1404C)
•
ZC Rubber Packing
(Product code: ZC55-9999G)
Voltage
Carry current
Current
Volt-amperes
Make
Break
Make
Break
120 VAC
10 A
60 A
6 A
7,200 VA
720 VA
240 VAC
30 A
3 A
Micro load
0.1 A, 125 VAC
0.1 A, 30 VDC
Rated voltage
Non-inductive load
Inductive load
Resistive load
Lamp load
Inductive load
Motor load
NC
NO
NC
NO
NC
NO
NC
NO
125 VAC
10 A
3 A
1.5 A
10 A
5 A
2.5 A
250 VAC
10 A
2.5 A
1.25 A
10 A
3 A
1.5 A
8 VDC
10 A
3 A
1.5 A
6 A
5 A
2.5 A
14 VDC
10 A
3 A
1.5 A
6 A
5 A
2.5 A
30 VDC
6 A
3 A
1.5 A
5 A
5 A
2.5 A
125 VDC
0.5 A
0.4 A
0.4 A
0.05 A
0.05 A
0.05 A
250 VDC
0.25 A
0.2 A
0.2 A
0.03 A
0.03 A
0.03 A
Inrush current
NC
30 A max.
NO
15 A max.