![background image](http://html.mh-extra.com/html/omron/z510/z510_specification-sheet_1633327002.webp)
B-54
Displacement sensors / Width-measuring Sensors
Basic System Configuration
Specifications
Controllers:
Z510-WC10E and Z510-WC15E
General Specifications
Characteristics
Note: This resolution is for measurements with an OMRON K3AS Linear Sen-
sor Controller connected and values averaged over 64 measurements.
Power supply
Z510-SW2T (0.5-m cable)
Z510-SW6 (0.5-m cable)
Z510-SW17 (0.5-m cable)
Sensor Extension Cables
Z519-SCIR (1.5 m, 3 m, 6 m, 8 m, 13 m, or 18 m)
Specify the required cable length when ordering.
Z510-WC10E
Z510-WC15E
Z300-KP
(2-m cable)
F150-VM
Monitor Cable (2 m)
BNC Jack
(Included with the F150-VM)
POWER
SYNC
ESC
TRIG
SHIFT
ENT
CONSOLE
Monitors
Up to 2 Sensors can be connected.
Controllers
Sensors
Console
Use the Monitor to check
the image and display
menus when making
F150-M05L
Color Liquid Crystal Monitor
(pin input)
Item
Specification
Supply voltage
21.6 to 26.4 VDC
Current
consumption
1 A max. (with 2 Sensors connected)
Insulation
resistance
20 M
Ω
min. (at 100 V DC) between DC exter-
nal terminals and GR terminal
(with internal surge absorber removed)
Dielectric
strength
1,000 VAC, 50/60 Hz between DC external ter-
minals and GR terminal (with internal surge
absorber removed)
Leakage current
10 mA max.
Noise resistance
1,500 V
P-P
; pulse width: 0.1
µ
s/1
µ
s; rising
edge: 1-ns pulse
Vibration
resistance
10 to 150 Hz (double amplitude of 0.1 mm)
for 8 minutes each in the X, Y, and Z direc-
tions
Shock resistance 200 m/s
2
3 times each in 6 directions
Ambient
temperature
Operating: 0 to 50
°
C (with no icing or con-
densation)
Storage: -15 to 60
°
C (with no icing or con-
densation)
Ambient
humidity
Operating and storage: 35% to 85% (with no
condensation)
Atmosphere
No corrosive gases
Grounding
Less than 100
Ω
Degree of
protection
IEC60529 IP20 (In-panel)
Material
Case: ABS
Item
Specification
Number of Sensors Up to 2 Sensors can be connected.
Number of scenes
16
Light intensity
tracking function
Automatic (The light intensity tracking
range can be specified.)
Fixed (Select one of 31 stages.)
Measurement
items
Select one of the following 6 items:
Deviation from reference surface, Bead
height, Width, Bead change, Peak/Bottom,
Inspection length
Region
specification
A region can be specified in the direction of
the line beam.
Data storage
2,048 points max.
Trigger function
Free-run, External 1, External 2, or Auto
Results output
Terminal block
8 input points: TRIGGER, LD-OFF, RE-
SET, DI0, and DI4 to DI7
12 output points:DO0 to DO5, DO8, DO15,
DO17 to DO19, and GATE
Monitor interface
1 channel (for pin jack or overscan monitor)
Analog output
resolution
The full-scale output can be divided into
40,000 gradations max.
Resolution (See note.): 0.25 mV (
±
5 V)
0.4
µ
A (4 to 20 mA)
Weight
Approx. 700 g (Controller only)
•
Judgement output
RS-232C output
Terminal block output
•
Measurement value output
(measurement value)
RS-232C output
Analog output
F502-EN2-04.book Seite 54 Dienstag, 26. Juli 2005 5:48 17