![background image](http://html.mh-extra.com/html/omron/z4m-w10/z4m-w10_manual_1633324010.webp)
Flat-blade
screwdriver
Offset adjustor
Span adjustor
Connect to an Intelligent
Panel Meter such as a
K3TX or K3TS.
Offset Adjustment
Offset adjustment is made using a white ceramic object before shipping,
so the user may not need to adjust the output.
To set the Sensor output to 0 V at the standard distance, connect an
Intelligent Panel Meter (such as K3TX or K3TS) to the output terminal of
the Sensor. Place a standard object in front of the Sensor and adjust the
output with the offset adjuster.
Span Adjustment
Span adjustment is made using a white ceramic object before shipping, so
the user may not need to adjust the span.
To calibrate the displacement output, adjust the span as follows.
1.
Locate the object at the standard distance and adjust the offset ad-
justment.
2.
Move the object for a specified distance and adjust the span adjuster
so that the voltage will change properly according to the displace-
ment.
Follow these steps to convert
±
4 V to
±
5V.
1.
Connect an Intelligent Panel Meter to the Sensor and move the object
so that the output will be 4 V.
2.
Use the span adjuster to adjust the voltage to 5 V.
Dimensions
Unit: mm (inch)
SENSOR: Z4M-S40 (FOR Z4M-W40), Z4M-S100 (FOR Z4M-W100)
Mounting Holes
Lens
(7 dia.)
Front face
Two 4.5-dia. mounting
holes
Measurement point
Vinyl-insulated round cable,
6.6 dia, standard length: 2 m
Connector
Emitting
axis
17
10.5
1.5
32
43
39
6.75
3.5
6.75
44
11
3.5
6.75
37
30
14.7 dia.
*
23
°
for Z4M-S40 and 11
°
for Z4M-S100.
**
40mm (1.6in) for Z4M-S40 and 100mm (3.9in) for Z4M-S100.
6.75
**
Two M4 Taps
37
±
0.2
39
±
0.2
44
(1.73)
(1.54)
(1.46)
17.6
(0.69)
46
(1.81)
26
*
Z4M
Z4M