14
ERROE
CODE
DESCRIPTION
SOLUTION
PEDAL
Pedal warning
-
Check or replace the pedal
-
Pedal not connected
-
Do not pedal yet
CARE
Safe Switch problem
-
Check the Safe Switch
-
Replace the safe switch
KEY1
Machine button
warning
-
Do not press machine button
-
Replace the buttons
E101
High AC voltage fault
-
Check mains voltage
-
Stabilize mains voltage
-
Use generator
E103
High Bus voltage fault
-
Check mains voltage
-
Stabilize mains voltage
-
Use generator
E106
Bus current overload
-
Check the encoder and motor
-
Replace the encoder
-
Replace the motor
E107
Motor blocked
-
Eliminate stiff movement in the machine
-
Replace the encoder
-
Replace the motor
E110
Encoder/Synchronizer
fault
-
check or replace the synchronizer for a
belt-drive machine
-
check or replace the encoder for a
direct-drive machine
E190
,
E290
Software Update
Error
-
Software update
-
Replace the control
E191,
E291
Software Update
Error
-
Software update
-
Replace the control
E193,
E293
Software Update
Error
-
Software update
-
Replace the control
E294
Software Update
Communication Error
-
Software update
-
Replace the control
E199
Software Update
Error
-
Software update
-
Replace the control
E900
Communication
problem
-
Restart the control
-
Replace the control
1.
Controller Check
Press hold
during power on, it will display “TEST” and then enter the Check
interface. Diplay A display check index, the else display contents.
1.1
Pedal
1.2
Synchronizer