background image

WL-N/WLG

40

Characteristics

Note:

The above figures are initial values.

*1. The values are calculated at an operating temperature of +5°C to +35°C, and an operating humidity of 40% to 70%RH. Contact your OMRON 

sales representative for more detailed information on other operating environments.

*2. Except Switches with Flexible Rod Actuators.

*3. 500,000 operations min. for Weather-resistant models.

*4. In case of models without operation indicators.

*5. For low-temperature models this is -40°C to +40°C (with no icing). For heat-resistant models the range is +5°C to 120°C.

* Except models with operation indicators.

Circuit Configuration/Terminal Connection Diagram

Note:

Leakage current from indicator circuit may cause load malfunction (i.e., the load may remain ON). Make sure that the load operating current 

is higher than the leakage current.

For countermeasures, refer to technical support on your OMRON website.

* Light-ON when not operating means the operation indicator is lit when the actuator is free and is not lit when the actuator rotates or is pushed 

down, and the Switch contacts contact to NO.

The above shows details of the switch interior. External wires (external resistances) are not shown. For details, refer to 

Operation

 on page 18.

Operating characteristics type

Basic models (WL-N)

High-sensitivity and High-precision models (WLG)

Permissible operating 
frequency

Mechanical

120 operations/minute

Electrical

30 operations/minute

Rated frequency

50/60 Hz

Permissible operating speed

1 mm/s to 1 m/s (in case of WLCA2-N)

Insulation resistance

100 M

Ω

 min. (at 500 VDC)

Contact resistance

25 m

Ω

 or less (default value, built-in switch only)

Vibration resistance

Malfunction

10 to 55 Hz, 1.5-mm double amplitude *2

Shock

Destruction

1,000 m/s

2

 max.

Malfunction

300m/s

2

 max. *2

Durability *1

Mechanical

15,000,000 operations min.

10,000,000 operations min. *3

Electrical

750,000 operations min. (3 A at 250 VAC, resistive load) *4

500,000 operations min. (3 A at 250 VAC, resistive load) *4

Ambient operating temperature

-10 to +80°C (with no icing) *5

Ambient operating humidity

35 to 95%RH

Degree of protection

IP67

Weight

Approx. 250 g (for WLCL-TH-N)

Approx. 250 g (for WLCL-TH-N)

Operating characteristics type

Basic models (WL-N)

High-sensitivity and High-precision models (WLG)

Wiring Specifications

Screw terminals/Direct-wire cable models

Screw terminals/Direct-wire cable models

Dielectric 
strength

Between terminals of the same 
polarity

1,000 VAC, 50/60 Hz for 1 min *

600 VAC, 50/60 Hz for 1 min *

Between currentcarrying metal 
part and ground

2,200 VAC, 50/60 Hz for 1 min

1,500 VAC, 50/60 Hz for 1 min

Between each terminal and 
non-current-carrying metal part

2,200 VAC, 50/60 Hz for 1 min

1,500 VAC, 50/60 Hz for 1 min

Operating characteristics type

Basic models (WL-N)/High-sensitivity and high-precision models (WLG)

Wiring Specifications

Screw terminals

Direct-wire cable

Without operation indicator

Operation indicator
(Light-ON when Not Operating *)

13(NO)

12(NC)

14(NO)

11(NC)

Za

NO

NC

NC

NO

White Black

Red Blue

Za

4 core

13(NO)

12(NC)

14(NO)

11(NC)

Internal

circuits

Za

NO

NC

NC

NO

Za

4 core

Internal

circuits

White Black

Red Blue

Summary of Contents for WL-N

Page 1: ...OMRON website Be sure to read Safety Precautions on pages 83 to 88 and Safety Precautions for All Limit Switches Select based on the operating temperature Ambient operating temperature of 5 C to 120...

Page 2: ...type P1 Weather resistant type Code Specifications None Standard built in switch 55 Airtight built in switch Code Specifications None Ambient operating temperature 10 to 80 C TH Ambient operating temp...

Page 3: ...istant type P1 Weather resistant type Code Specifications None Standard Built in Switch 55 Airtight built in switch Code Specifications None Ambient operating temperature 10 to 80 C TH Ambient operati...

Page 4: ...2 RP60 N NC wiring WLCA2 RP60LD2 N NO wiring WLCA2 RP60LD3 N 25 5 WLCA2 2RP60 N NC wiring WLCA2 2RP60LD2 N NO wiring WLCA2 2RP60LD3 N 10 WLG2 RP60 NC wiring WLG2 RP60LD2 NO wiring WLG2 RP60LD3 5 WLGCA...

Page 5: ...re Specifications Pretravel PT Without operation indicator Model Sealed top roller plunger Screw terminals Conduit size G1 2 Heat resistant type 1 7 mm max WLD28 TH N Cold resistant type WLD28 TC N Co...

Page 6: ...Conduit size G1 2 Corrosion resistant type 40 20 mm WLNJ 2RP N Direct wire cable Coolant resistant type 40 20 mm WLNJ 2RP60 N Molded terminal 139 WLNJ 2139 N Molded terminal 140 WLNJ 2140 N Adjustabl...

Page 7: ...Resistive load Lamp load Inductive load Motor load Voltage V NC NO NC NO NC NO NC NO AC 125 10 3 1 5 10 5 2 5 250 10 2 1 10 3 1 5 500 10 1 5 0 8 3 1 5 0 8 DC 8 10 6 3 10 6 14 10 6 3 10 6 30 6 4 3 6 4...

Page 8: ...z Permissible operating speed 1 mm s to 1 m s in case of WLCA2 N Insulation resistance 100 M min at 500 VDC Contact resistance 25 m or less default value built in switch only Vibration resistance Malf...

Page 9: ...CT cable Finished outer diameter 11 5 mm 4 conductors Resin cap 1 Fluorine rubber is used for all rubber parts 2 The connector can be removed so it is possible to use flexible conduit for the cable WL...

Page 10: ...M5 Allen head bolt JIS B 0202 G1 2 68 7 21 6 53 2 0 8 42 max 29 2 1 2 Four M6 1 0 Depth 15 min 25 4 25 4 13 1 Roller lever R38 Heat resistant type WLCA2 TH N WLCA2 2TH N WLCA2 2NTH N Cold resistant t...

Page 11: ...p length 5 mm 17 5 7 dia 125 4 9 15 1 40 0 7 30 2 0 2 58 7 0 2 14 7 R38 Four 5 2 dia holes 2 M3 5 Three M4 Stainless sintered roller 5 60 max 12 7 40 1 5 41 5 1 5 53 1 5 M5 Allen head bolt 68 7 21 6 5...

Page 12: ...60 max 12 7 40 1 5 41 5 1 5 53 1 5 25 4 13 1 68 7 Four M6 1 0 Depth 15 min 25 4 21 6 53 2 0 8 42 max 29 2 1 2 Four 5 2 dia holes Three M4 SC 3M M5 Allen head bolt 17 5 7 dia 125 58 7 0 2 14 7 R38 5 4...

Page 13: ...Four 5 2 dia holes Stainless sintered roller 5 Adjustable range 25 to 89 67 max 12 7 41 5 1 5 60 1 5 M5 Allen head bolt JIS B 0202 G1 2 68 7 65 2 0 8 42 max 21 6 29 2 1 2 Four M6 1 0 Depth 15 min 25 4...

Page 14: ...1 2 Four M6 1 0 Depth 15 min 25 4 25 4 13 1 Vinyl cabtire cable VCT JIS C 3312 Nominal cross section 1 25 mm2 0 18 50 4 cores Strip length 5 mm Adjustable Roller Lever R25 to 89 mm Coolant resistant s...

Page 15: ...ations WLD28 TC N Corrosion resistant specifications WLD28 RP N Note The photo shows the WLD28 TH N model Four 5 2 dia holes 17 4 6 dia PT 30 2 0 2 40 0 7 4 9 5 58 7 0 2 15 1 OP 4 M3 5 Three M4 13 1 1...

Page 16: ...8 140 N Four 5 2 dia holes 17 4 6 dia PT 30 2 0 2 40 0 7 4 9 5 58 7 0 2 15 1 OP 4 M3 5 Three M4 13 1 12 9 21 6 29 2 1 2 42 max 68 7 28 4 Four M6 1 0 Depth 15 min Stainless sintered roller Vinyl cabtir...

Page 17: ...5 6 5 dia 1 Do not operate the Switch in the direction of the axial center 2 Stainless steel coil spring 3 The range for operation is 1 3rd of the overall spring length from the end of the spring JIS...

Page 18: ...pring 3 The range for operation is 1 3rd of the overall spring length from the end of the spring 20 30 2 0 2 40 0 7 15 1 4 9 Vinylcabtirecable VCTJISC3312 Nominalcross section 1 25mm2 0 18 50 4cores S...

Page 19: ...L 3H4100 N 20 max WLCL 2N N WLRCA2 2N N WL 1H4100 N 10 WLGL WLRG2 WL 2H4100 K Sealed top plunger 1 7 mm max WLD18 N WL 7H100 N Sealed top roller plunger 1 7 mm max WLD28 N WL 7H400 N Sealed top ball p...

Page 20: ...dia 11 dia SC 5M Cabtire cable Metal 7 dia 5 5 dia 7 5 dia SC 21 9 dia 7 5 dia 9 5 dia SC 22 12 5 dia 11 dia 13 dia SC 23 14 dia 12 dia 14 dia SC 24 11 dia 9 dia 11 dia SC 25 Cabtire cable Resin 9 di...

Page 21: ...XS2F A421 G90 F for DC 2 2 XS2F D421 DD0 WL K13 N WL M1J N WLG K13 WLG M1J 5 XS2F D421 GD0 2 XS2F D421 DA0 F WL M1GJ N WLG M1GJ 5 XS2F D421 GA0 F 4 2 XS2F D421 D80 F WL K43 N WL M1JB N WL DGJ N WL DK1...

Page 22: ...5 dia M12 1 45 5 dia M12 1 for DC for AC XS5F D421 80 F 40 7 L Cable length 50 30 5 M12 1 14 9 dia 1 2 3 4 Brown Blue Terminal No Cable color of core sheath 1 2 3 4 Blue Black Brown White Terminal No...

Page 23: ...1 4 10 61 5 Brown 3 Blue 4 M4 crimp terminal 1 4 3 2 JIS B0202 G 30 dia SC 2F Built in DC connector 27 8 5 4 10 1 4 3 2 M12 1 61 5 Brown 3 Blue 4 M4 crimp terminal JIS B0202 G 30 dia SC 2FAD Built in...

Page 24: ...1A118 Nylon Roller Roller Width 30 mm 11 4 38 16 54 8 17 9 12 6 17 5 dia length 7 stainless sintered roller 7 3 dia mounting holes Two M5 Allen head nut and arm set screw WL 1A105 Double Nuts 11 4 38...

Page 25: ...Resin Roller 6 2 155 75 23 15 8 Adjustable lever stainless steel Adjustable range 25 to 140 19 7 0 8 24 9 0 8 17 5 dia length 7 stainless sintered roller 7 3 dia mounting holes M5 Allen head bolt WL...

Page 26: ...bolt 13 4 8 0 4 65 2 25 5 max Adjustable from 650 to 660 7 3 dia mounting holes 3 2 dia stainless steel rod WL 3A108 7 5 7 5 11 6 13 95 M5 Allen head bolt 450 4 417 5 2 24 6 max 7 3 dia mounting holes...

Page 27: ...O2 ammonium gas NH3 nitric gas HNO3 or chlorine gas Cl2 or high temperature and humidity Otherwise contact failure or corrosion damage may result Do not disassemble and or modify the switch at anytime...

Page 28: ...necting the wires directly to the terminal Instead attach using a crimp terminal In the case of indicator unit to avoid interference between lump unit and crimp terminals wire according to right wirin...

Page 29: ...nce a contact has been used to open and close a load it can no longer be used for lower loads Doing so will damage the contact surface and reduce contact reliability If an inrush current or other sudd...

Page 30: ...ch be sure to adjust the Limit Switch carefully while considering the whole movement of the actuator The Limit Switch may soon malfunction if the OT is excessive Therefore adjustments and careful cons...

Page 31: ...WLCL N WLCL 2 N WLCL 2N N WLGL WLCAL4 N WLCAL5 N Horizontal plunger WLSD N Top roller plunger WLD2 N Sealed top roller plunger WLD28 N Fork lock lever WLCA32 4 N Note Does not include RP60 Series or 1...

Page 32: ...d or Lever The length of the rod or lever can be adjust ed by loosening the Allen head bolt Adjustable roller lever WLCA12 N WLCA12 2 N WLCA12 2N N WLG12 Adjustable rod lever WLCL N WLCL 2 N WLCL 2N N...

Page 33: ...CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED IN CONTRACT WARRANTY NEGLIGENCE OR STRICT LIABILITY Further in no event shall liability of Omron Companies exceed the individual price of the Pr...

Page 34: ...60169 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia omron co...

Reviews: