background image

The latest encryption technology combined with OMRON'S 
original encryption technology forms a strong security 
environment.
The FA Wireless LAN contains the following security features.

Secure and easy to implement at FA sites.

With the popular Received Signal Strength 
Indicator (RSSI), the status of invisible 
radio waves can be easily identified by 
checking the indicators.

Various antennas are available for different installation locations (optional).

Stable operation even in harsh FA environments!

OMRON'S original security system prevents important 
production information from being disclosed. 

Signal status can be observed!

Versatile and easy installation!

Security

 Type of FA Wireless LAN Security and Effectiveness

 Received Signal Strength Level

SSID

MAC Address Filtering

WEP

WPA-PSK (TKIP/AES)

  : Very good,     : Good,     : Satisfactory,      : Not very good

Access control Encryption Security level

OCB AES

WOC KEY (OMRON'S original encryption)

Low

High

Screwless terminal block

Unable to

establish

communications

POWER

RSSI

LAN WIRELESS

Unstable

POWER

RSSI

LAN WIRELESS

Usable

POWER

RSSI

LAN WIRELESS

POWER

RSSI

LAN WIRELESS

Stable

The Wireless LAN Unit has the same level of noise and 
environmental resistance as OMRON FA Devices, such as 
PLCs and Power Supply Units. It is capable of stable 
operation when installed within the same control panel as 
other FA devices. 
There is no need to reset 
the power supply even 
if the Wireless LAN 
Unit runs out of 
control because it 
will automatically 
restart itself. 

Note:

 Partly quoted from the Wireless Security Guidelines (Ministry of 

Internal Affairs and Communications).

This Wireless LAN Unit can be easily 
installed anywhere on a DIN Rail or 
a wall.

In addition to the included Pencil Antenna, the popular Magnetic-base Antenna is available.
The FA Wireless LAN Unit can be installed inside the control panel and the Antenna on the 
outside of the control panel.

Directional Magnetic-base Antenna

 Signal Direction 

    from Antenna

Note:

 Cannot be used outdoors.

Side view

Top view

Signal range

Antenna

Easy Installation

2.4-GHz/5-GHz 
Dual-band compatible

Use magnets to mount 
it on metal surfaces!

Install it in the 
control panel with 
other FA devices!

Easy connection to 
power supplies using 
the screwless terminal.

3

Good noise resistance 
can be obtained by 
connecting the Wireless 
Unit to an OMRON 
Power Supply Unit.

Summary of Contents for WE70

Page 1: ...New Product News WE70 FA Wireless LAN Unit Reliable Wireless Ethernet for Harsh FA Environments Conforms to IEEE 802 11a b g Construct an Ideal Wireless LAN System for FA Applications...

Page 2: ...s 2 4 GHz band OFDM Five times faster than 11b Noise resistant Less cross talk with other devices Multiple 8 channels can be used simultaneously Wide selection of products Long communications distanc...

Page 3: ...I LAN WIRELESS POWER RSSI LAN WIRELESS Stable The Wireless LAN Unit has the same level of noise and environmental resistance as OMRON FA Devices such as PLCs and Power Supply Units It is capable of st...

Page 4: ...Window Secure and easy to implement at FA sites There are three transmitter output levels By setting the level to low you can reduce its influence on other systems within the same area and more syste...

Page 5: ...on data can be managed as a batch The roaming function allows systems to be moved and communicate with mobile devices WE70 AP Access point WE70 AP Access Point repeater Maximum of 6 repeaters WE70 CL...

Page 6: ...urope Access Point Master WE70 AP EU Client Slave WE70 CL EU USA Access Point Master WE70 AP US Client Slave WE70 CL US China Access Point Master WE70 AP CN Client Slave WE70 CL CN Type Specifications...

Page 7: ...otection IP20 Terminal construction Power terminal Screwless terminal block Phoenix Contact AI 0 75 10 or equivalent Applicable Standards FCC UL USA CE Marking EU Chinese Electromagnetic Standards Mai...

Page 8: ...s to IEEE 802 3 10Base T 100Base TX Interface RJ 45 1 Item Specification Wireless LAN Unit Setup Web browser Microsoft Internet Explorer 6 0 7 0 or higher OS Windows Vista XP or 2000 See note Frequenc...

Page 9: ...ches the received signal status indicator to flashing or four level lit display POWER Indicator Green Displays the power source status and the operation mode of the Wireless LAN Unit RSSI Indicator Or...

Page 10: ...0 Four 5 dia holes 1 5 Four 4 2 dia holes Use flat head screws 6 6 Access Point Master WE70 AP EU US CN Client Slave WE70 CL EU US CN Note Leave a gap of approx 20 mm around the sides of the Wireless...

Page 11: ...E MODIFICATION OR REPAIR Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combination of the produ...

Page 12: ...aan 67 69 NL 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg IL 60173 5302 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 OMRON...

Reviews: