background image

Read and Understand this Catalog

Please read and understand this catalog before purchasing the product. Please consult your OMRON representative if you have 
any questions or comments.

Warranty and Limitations of Liability

WARRANTY

OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year 
(or other period if specified) from date of sale by OMRON.

OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, 
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER 
ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET 
THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR 
IMPLIED.

LIMITATIONS OF LIABILITY

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, 
OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON 
CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.

In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.

IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE 
PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, 
INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE 
MODIFICATION OR REPAIR.

Application Considerations

SUITABILITY FOR USE

OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the 
product in the customer's application or use of the product.

Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will 
be used.

Know and observe all prohibitions of use applicable to the product.

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT 
ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON 
PRODUCT ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR 
SYSTEM.

PROGRAMMABLE PRODUCTS

OMRON shall not be responsible for the user’s programming of a programmable product, or any consequence thereof.

Disclaimers

CHANGE IN SPECIFICATIONS

Product specifications and accessories may be changed at any time based on improvements and other reasons. Consult with 
your OMRON representative at any time to confirm actual specifications of purchased products.

DIMENSIONS AND WEIGHTS

Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.

PERFORMANCE DATA

Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a 
warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application 
requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability

.

Summary of Contents for WE70

Page 1: ...New Product News WE70 FA Wireless LAN Unit Reliable Wireless Ethernet for Harsh FA Environments Conforms to IEEE 802 11a b g Construct an Ideal Wireless LAN System for FA Applications...

Page 2: ...s 2 4 GHz band OFDM Five times faster than 11b Noise resistant Less cross talk with other devices Multiple 8 channels can be used simultaneously Wide selection of products Long communications distanc...

Page 3: ...I LAN WIRELESS POWER RSSI LAN WIRELESS Stable The Wireless LAN Unit has the same level of noise and environmental resistance as OMRON FA Devices such as PLCs and Power Supply Units It is capable of st...

Page 4: ...Window Secure and easy to implement at FA sites There are three transmitter output levels By setting the level to low you can reduce its influence on other systems within the same area and more syste...

Page 5: ...on data can be managed as a batch The roaming function allows systems to be moved and communicate with mobile devices WE70 AP Access point WE70 AP Access Point repeater Maximum of 6 repeaters WE70 CL...

Page 6: ...urope Access Point Master WE70 AP EU Client Slave WE70 CL EU USA Access Point Master WE70 AP US Client Slave WE70 CL US China Access Point Master WE70 AP CN Client Slave WE70 CL CN Type Specifications...

Page 7: ...otection IP20 Terminal construction Power terminal Screwless terminal block Phoenix Contact AI 0 75 10 or equivalent Applicable Standards FCC UL USA CE Marking EU Chinese Electromagnetic Standards Mai...

Page 8: ...s to IEEE 802 3 10Base T 100Base TX Interface RJ 45 1 Item Specification Wireless LAN Unit Setup Web browser Microsoft Internet Explorer 6 0 7 0 or higher OS Windows Vista XP or 2000 See note Frequenc...

Page 9: ...ches the received signal status indicator to flashing or four level lit display POWER Indicator Green Displays the power source status and the operation mode of the Wireless LAN Unit RSSI Indicator Or...

Page 10: ...0 Four 5 dia holes 1 5 Four 4 2 dia holes Use flat head screws 6 6 Access Point Master WE70 AP EU US CN Client Slave WE70 CL EU US CN Note Leave a gap of approx 20 mm around the sides of the Wireless...

Page 11: ...E MODIFICATION OR REPAIR Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards codes or regulations that apply to the combination of the produ...

Page 12: ...aan 67 69 NL 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 OMRON ELECTRONICS LLC One Commerce Drive Schaumburg IL 60173 5302 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 OMRON...

Reviews: