Communications Preparations
Auto Command Cancel Time
The auto command cancel time is used to set the amount of time from after an auto command is sent
until the command processing will be aborted.
After waiting for the tag for a fixed period of time, an " RF Tag non-existent" error (error code: 72) will be
returned to the host device.
Write Protection Enable Setting
The write protection enable setting can be used to enable or disable write protection.
00: Write protection function disabled
01: Write protection function enabled default value
For details on write protection settings, refer to
.
Protocol Switch
The protocol switch is used to set whether the Hand-held Reader/Writer will use the V680 command
format or the V600 command format.
0: V600 commands (default value)
1: V680 commands
For details, refer to
.
Tag Memory Setting
The CA1D Mode in the Tag memory setting is used only when using the V680-CA1D/-CA2D.
If you are using the V680-CA1D/-CA2D, set the Tag memory setting to CA1D Mode.
If you are not using the V680-CA1D/-CA2D, set the Tag memory setting to Standard Mode.
0: Standard Mode (default value)
1: CA1D Mode
Refer to Using Heat-resistive Tags (V680-D1KP58HTN and V680-D1KP58HT) in
for infor-
mation on using Using Heat-resistive Tags (V680-D1KP58HTN or V680-D1KP58HT).
CA1D Mode can be used with version 1.1 or newer.
Use the VERSION READ (VS) command to read the product version. For details on the VERSION READ (VS) com-
mand, refer to
VERSION READ (VS)
under
V680 Commands or V600 Commands
in
Section 3 Commands
.
Setting range
0 to 99 (s)
Note:
Default value: 60 (s)