53
Diagnostics
Section 5-2
5-2
Diagnostics
Errors
Errors that Stop Operation
If a hardware error of the ID Controller has occurred, the STOP indicator
lights, and RUN output is turned OFF.
Errors that Allow
Operation to Continue
If an error has occurred during communications between the ID Controller and
the host computer, or between the Controller and the R/W Head, the error
code is displayed on the monitor (error code display mode). Up to 30 error
codes are recorded and can be read by the host controller.
Indicators and Outputs
Note USR: Set by the controller control command.
TSx x x_x
00
x x x
*
TSx x x_x
00
x x x
*
Frame 1
Response of host computer
Response of test data
Test data: 262 characters max.
Reception
Transmission
Status
Indicator
Monitor
Output
POWER
HEAD
STOP
RUN
End of
process-
ing
User 1
User 2
Test
Lower process-
ing in progress
Lit
Lit
Not lit
---
OFF
OFF
---
---
Lower process-
ing interval
Lit
Not lit
Not lit
---
OFF
OFF
---
---
Communication
error occurrence
Lit
Not lit
Not lit
Error
code
OFF
OFF
---
---
RUN
Command
reception wait
Lit
Not lit
Not lit
---
ON
OFF
---
---
Command pro-
cessing in
progress
Lit
Lit
Not lit
---
ON
OFF
USR
USR
Communication
error occurrence
Lit
Not lit
Not lit
Error
code
ON
ON
---
---
Stop error
CPU error
Lit
Not lit
Lit
92
OFF
OFF
---
---
Memory error
Lit
Not lit
Lit
93
OFF
OFF
Emergency
stop
External reset
input ON
Lit
---
Lit
---
OFF
OFF
---
---
Summary of Contents for V600 RFID System
Page 1: ...OPERATION MANUAL Cat No Z193 E1 01 Board Type ID Controller V600 RFID System V600 CM1D...
Page 2: ...V600 RFID System V600 CM1D Board Type ID Controller Operation Manual Produced December 2003...
Page 3: ...iv...
Page 7: ...viii...
Page 10: ...xii...
Page 16: ...6 User I O Section 1 4...
Page 24: ...14 Outline Size Section 2 5...
Page 60: ...50 Communication Time Section 4 6...
Page 82: ...72 Index...
Page 84: ...74 Revision History...
Page 87: ...V6001 RFID System V600 CM1D Board Type ID Controller Cat No Z193 E1 01 OPERATION MANUAL...