19
Output Data Format
Section 3-3
3-3
Output Data Format
Note
Error outputs can be enabled or disabled via a setting. The
default is “OFF” (disabled).
Item
Setting
Header
Any of the following can be selected from the
Console. The default is “none.”
• None
• STX
• ESC
FCS
Any of the following can be selected from the
Console. The default is “OFF.”
• OFF
• ON
Footer
Any of the following can be selected from the
Console. The default is “CR.”
• CR
• LF
• CR+LF
Header
Reading data
FCS
Footer