Figure 11 Sensor calibration
4.3 Main Thread Nodes
4.3.1 CVNewObj Node
Return to
Conveyor main thread
to select
CVNewObj
node.
This node indicates that the robot is waiting for valid objects that have been detected
by the sensor and will move to the robot’s New Object Range within the Working Area
(refer to
Section 4.1.2
for details about range and area).
Conveyor NO
: Selected conveyor
Time Out:
Set the waiting time for a valid
object, which is detected within New
Object Range.
•
When Time Out = 0, it indicates no
time out is set.
When a valid object enters the robot
operating range, the thread will go to the
next node.