Precautions

Safety Precautions

Power Supply

Do not impose an excessive voltage on the TL-T, otherwise it may be 
damaged. Do not impose AC current (100 to 240 VAC) on any DC 
model, otherwise it may be damaged.

Load Short-circuit

Do not short-circuit the load, or the TL-T may be damaged.

The TL-T’s short-circuit protection function will be valid if the polarity 
of the supply voltage imposed is correct and within the rated voltage 
range.

Wiring

Be sure to wire the TL-T and load correctly, otherwise it may be
damaged.

Do not expose the

 

product to flammable or explosive gases.

Do not disassemble, repair, or modify the product.

Correct Use

Designing

Power Reset Time

The Proximity Sensor is ready to operate within 100 ms after power 
is supplied. If power supplies are connected to the Proximity Sensor 
and load respectively, be sure to supply power to the Proximity 
Sensor before supplying power to the load.

Effects of Surrounding Metal

When mounting the TL-T within a metal panel, ensure that the 
clearances given in the following table are maintained.

Power OFF

The Proximity Sensor may output a pulse signal when it is turned

 

OFF. Therefore, it is recommended that the load be turned OFF

 

before turning OFF the Proximity Sensor.

Power Supply Transformer

When using a DC power supply, make sure that the DC power

 

supply has an insulated transformer. Do not use a DC power

 

supply 

with an auto-transformer.

Mutual Interference

When installing two or more Sensors face-to-face or side-by-side, 
ensure that the minimum distances given in the following table are 
maintained.

Type

Dimension

Minimum value

Shielded

w

0

n

-

D

0

m

6

Non-shielded

w

12

n

36

D

8

m

12

w

(Unit: mm)

Type

Dimension

Minimum value

Shielded

A

30

B

10

Non-shielded

A

40

B

20

 

A

B

 

(Unit: mm)

Summary of Contents for TL-T

Page 1: ...e wired PVC dia 4mm WA Pre wired PUR PVC dia 4mm WR Robot cable PVC dia 4mm M5 M8 connector 3 pole M1J M12 connector 4 pole with pig tail cable PVC M3J M8 connector 4 pole with pig tail cable PVC M5J M8 connector 3 pole with pig tail cable PVC 8 Production site E European Union 9 Cable length Blank Connector type Numeral Cable type Installation Sensing distance Connection Output configuration Oper...

Page 2: ...utput Indicator Output indicator Yellow LED Operation mode with sensing object approaching TL T E1 F1 models NO TL T E2 F2 models NC TL T E3 F3 models NO NC For details refer to Timing Charts Protection circuits Output reverse polarity protection Power source circuit reverse polarity protection Surge suppressor Short circuit protection Ambient air temperature Operating Storage 25 C to 70 C Tempera...

Page 3: ... 0 3 0 2 0 1 0 0 0 1 0 2 0 3 0 4 0 5 0 Distance Y mm Sensing distance X mm X Y TL T2 TL T4M 0 0 0 5 1 0 1 5 2 0 2 5 0 5 10 15 20 25 30 35 Side length of sensing object d mm Sensing distance x mm Iron Stainless steel Brass Aluminum Copper X d TL T2 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 4 5 5 0 0 5 10 15 20 25 30 35 Side length of sensing object d mm Sensing distance x mm X d Iron Stainless steel Bras...

Page 4: ...Brown 1 Black 4 Blue 3 1 4 3 M8 connector 3 pin Pin Arrangement ON OFF ON OFF Non sensing zone Sensing zone Control output Yellow indicator 100 0 Sensing object Rated sensing distance Load V 0 V Brown 1 Black 4 Blue 3 1 4 3 Main circuit M8 connector 3 pin Pin Arrangement ON OFF NC output ON OFF ON OFF Non sensing zone Sensing zone NO output Yellow indicator 100 0 Sensing object Rated sensing dista...

Page 5: ...onnector 3 pin Pin Arrangement 1 4 3 Main circuit 0 V ON OFF ON OFF Non sensing zone Sensing zone Control output Yellow indicator 100 0 Sensing distance Rated sensing distance V Load Brown 1 Black 4 Blue 3 M8 connector 3 pin Pin Arrangement 1 4 3 Main circuit 0 V ON OFF NC output ON OF ON OFF Non sensing zone Sensing zone NO output Yellow indicator 100 0 Sensing object Rated sensing distance Blue ...

Page 6: ...erwise stated Pre wired Models shielded and non shielded TL T2 E 2M and TL T4M E 2M M8 Connector Models shielded and non shielded TL T2 M5 E and TL T4M M5 E 26 4 5 3 2 4 3 3 4 0 7 6 40 12 4 4 5 16 18 LED insert nut M3 4 3 2 3 3 40 12 26 5 6 16 18 4 0 7 4 4 5 M8 LED insert nut M3 ...

Page 7: ...nected to the Proximity Sensor and load respectively be sure to supply power to the Proximity Sensor before supplying power to the load Effects of Surrounding Metal When mounting the TL T within a metal panel ensure that the clearances given in the following table are maintained Power OFF The Proximity Sensor may output a pulse signal when it is turned OFF Therefore it is recommended that the load...

Page 8: ...ever disassemble or repair the Sensor Environment Water Resistivity The Proximity Sensors are tested intensively on water resistance but in order to ensure maximum performance and life expectancy avoid immersion in water and provide protection from rain or snow Operating Environment Ensure storage and operation of the Proximity Sensor within the given specifications Inrush Current A load that has ...

Reviews: