Precautions
Safety Precautions
Power Supply
Do not impose an excessive voltage on the TL-T, otherwise it may be
damaged. Do not impose AC current (100 to 240 VAC) on any DC
model, otherwise it may be damaged.
Load Short-circuit
Do not short-circuit the load, or the TL-T may be damaged.
The TL-T’s short-circuit protection function will be valid if the polarity
of the supply voltage imposed is correct and within the rated voltage
range.
Wiring
Be sure to wire the TL-T and load correctly, otherwise it may be
damaged.
Do not expose the
product to flammable or explosive gases.
Do not disassemble, repair, or modify the product.
Correct Use
Designing
Power Reset Time
The Proximity Sensor is ready to operate within 100 ms after power
is supplied. If power supplies are connected to the Proximity Sensor
and load respectively, be sure to supply power to the Proximity
Sensor before supplying power to the load.
Effects of Surrounding Metal
When mounting the TL-T within a metal panel, ensure that the
clearances given in the following table are maintained.
Power OFF
The Proximity Sensor may output a pulse signal when it is turned
OFF. Therefore, it is recommended that the load be turned OFF
before turning OFF the Proximity Sensor.
Power Supply Transformer
When using a DC power supply, make sure that the DC power
supply has an insulated transformer. Do not use a DC power
supply
with an auto-transformer.
Mutual Interference
When installing two or more Sensors face-to-face or side-by-side,
ensure that the minimum distances given in the following table are
maintained.
Type
Dimension
Minimum value
Shielded
w
0
n
-
D
0
m
6
Non-shielded
w
12
n
36
D
8
m
12
w
n
m
D
w
(Unit: mm)
Type
Dimension
Minimum value
Shielded
A
30
B
10
Non-shielded
A
40
B
20
A
B
(Unit: mm)