![background image](http://html.mh-extra.com/html/omron/tl-t/tl-t_datasheet_1633282002.webp)
D-62
Inductive Sensors
Specifications
DC 3-wire and DC 4-wire Models
Note: 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard target distance between
targets, and a setting distance of half the sensing distance
2. PUR Cable and other legth request
Type
Item
Shielded
Non-shielded
TL-T2E1-
@@
-E
TL-T2F1-
@@
-E
TL-T2E2-
@@
-E
TL-T2F2-
@@
-E
TL-T2E3-E
TL-T2F3-E
TL-T4ME1-
@@
-E
TL-T4MF1-
@@
-E
TL-T4ME2-
@@
-E
TL-T4MF2-
@@
-E
TL-T4ME3-E
TL-T4MF3-E
Sensing distance
2 mm
±
10%
4 mm
±
10%
Setting distance
0 to 1.6 mm
0 to 3.2 mm
Differential travel
15% max. of sensing distance
Target
Ferrous metal (The sensing distance decreases with non-ferrous metal)
Standard target
12 x 12 x 1 mm
12 x 12 x 1 mm
Response frequency (See note 1.)
3000 Hz
1500 Hz
Rated power supply voltage
(operating voltage range)
24 VDC. Ripple (p-p): 10% max.
(10 to 35 VDC)
Current consumption
DC 3-wire:
≤
15 mA at 24 VDC
DC 4-wire:
≤
15 mA at 24 VDC
Output type
TL-T
@@
E
models: NPN voltage output
TL-T
@
@
F
models: NPN voltage output
Control output
Load current
300 mA max. each output
Residual volt-
age
≤
2.0 VDC
Leakage current
DC 3-wire: <0,5 mA
DC 4-wire: <1 mA each output
Indicator
Output indicator (Yellow LED)
Operation mode
(with sensing object approaching)
TL-T
@@
E1/F1
models: NO
TL-T
@@
E2/F2
models: NC
TL-T
@@
E3/F3
models: NO + NC
For details, refer to
Timing Charts
.
Protection circuits
Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor,
Short-circuit protection
Ambient air temperature
Operating/Storage: –25
°
C to 70
°
C
Temperature influence
≤±
10% max. of Sn at 23°C in temperature range of –25
°
C to 70
°
C
Humidity
35% to 95% RH
Voltage influence
±
1% max. of sensing distance in the rated voltage range
±
15%
Insulation resistance
>10 M
Ω
between current-carrying parts and case
Dielectric strength
1000 VAC at 50/60 Hz between current-carrying parts and case
Vibration resistance
0 to 55 Hz with 30 min. dwell time at resonance frequency or 55 Hz each in X, Y, and Z directions
55 to 2000 Hz, 150 m/s
2
, double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance
300 m/s
2
6 times each in X, Y, and Z directions
Degree of protection
in accordance with IEC 60529:
Pre-wired models: IP67
M8 connector models: IP65
Product standard
EN60947-5-2
Connection method
Pre-wired (See
note 2)
2m cable, 3x 0,25 mm
2
for DC 3-wire models
4x 0,25 mm
2
for DC 4-wire models
Connector
M8 connector
Weight
(packaged)
Pre-wired model Approx. 70 g
M8 connector
models
Approx. 20 g
Material
Case
PBT
Cable
PVC