background image

D-62

Inductive Sensors

Specifications

DC 3-wire and DC 4-wire Models

Note: 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard target distance between

targets, and a setting distance of half the sensing distance

2. PUR Cable and other legth request

Type

Item

Shielded

Non-shielded

TL-T2E1-

@@

-E

TL-T2F1-

@@

-E

TL-T2E2-

@@

-E

TL-T2F2-

@@

-E

TL-T2E3-E
TL-T2F3-E

TL-T4ME1-

@@

-E

TL-T4MF1-

@@

-E

TL-T4ME2-

@@

-E

TL-T4MF2-

@@

-E

TL-T4ME3-E
TL-T4MF3-E

Sensing distance

2 mm 

±

10%

4 mm 

±

10%

Setting distance

0 to 1.6 mm

0 to 3.2 mm

Differential travel

15% max. of sensing distance

Target

Ferrous metal (The sensing distance decreases with non-ferrous metal)

Standard target

12 x 12 x 1 mm

12 x 12 x 1 mm

Response frequency (See note 1.)

3000 Hz

1500 Hz

Rated power supply voltage 
(operating voltage range)

24 VDC. Ripple (p-p): 10% max. 

(10 to 35 VDC)

Current consumption

DC 3-wire: 

15 mA at 24 VDC

DC 4-wire: 

15 mA at 24 VDC

Output type

TL-T

@@

E

 

models: NPN voltage output

TL-T

@

@

F

 

models: NPN voltage output

Control output

Load current

300 mA max. each output

Residual volt-
age

2.0 VDC

Leakage current

DC 3-wire: <0,5 mA

DC 4-wire: <1 mA each output

Indicator

Output indicator (Yellow LED)

Operation mode 
(with sensing object approaching)

TL-T

@@

E1/F1

 

models: NO

TL-T

@@

E2/F2

 

models: NC

TL-T

@@

E3/F3

 

models: NO + NC

For details, refer to 

Timing Charts

.

Protection circuits

Output reverse  polarity protection, Power source circuit reverse polarity protection, Surge suppressor, 
Short-circuit protection

Ambient air temperature

Operating/Storage: –25

°

C to 70

°

Temperature influence

≤±

10% max. of Sn at 23°C in temperature range of –25

°

C to 70

°

C

Humidity

35% to 95% RH

Voltage influence

±

1% max. of sensing distance in the rated voltage range 

±

15%

Insulation resistance

>10 M

 between current-carrying parts and case

Dielectric strength

1000 VAC at 50/60 Hz between current-carrying parts and case

Vibration resistance

0 to 55 Hz with 30 min. dwell time at resonance frequency or 55 Hz each in X, Y, and Z directions

55 to 2000 Hz, 150 m/s

2

, double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance

300 m/s

2

 6 times each in X, Y, and Z directions

Degree of protection

in accordance with IEC 60529:

Pre-wired models: IP67

M8 connector models: IP65

Product standard

EN60947-5-2

Connection method

Pre-wired (See 
note 2)

2m cable,  3x 0,25 mm

 for DC 3-wire models

4x 0,25 mm

 for DC 4-wire models

Connector

M8 connector

Weight 
(packaged)

Pre-wired model Approx. 70 g

M8 connector 
models

Approx. 20 g

Material

Case

PBT

Cable

PVC

Summary of Contents for TL-T

Page 1: ...e wired PVC dia 4mm WA Pre wired PUR PVC dia 4mm WR Robot cable PVC dia 4mm M5 M8 connector 3 pole M1J M12 connector 4 pole with pig tail cable PVC M3J M8 connector 4 pole with pig tail cable PVC M5J M8 connector 3 pole with pig tail cable PVC 8 Production site E European Union 9 Cable length Blank Connector type Numeral Cable type Installation Sensing distance Connection Output configuration Oper...

Page 2: ...utput Indicator Output indicator Yellow LED Operation mode with sensing object approaching TL T E1 F1 models NO TL T E2 F2 models NC TL T E3 F3 models NO NC For details refer to Timing Charts Protection circuits Output reverse polarity protection Power source circuit reverse polarity protection Surge suppressor Short circuit protection Ambient air temperature Operating Storage 25 C to 70 C Tempera...

Page 3: ... 0 3 0 2 0 1 0 0 0 1 0 2 0 3 0 4 0 5 0 Distance Y mm Sensing distance X mm X Y TL T2 TL T4M 0 0 0 5 1 0 1 5 2 0 2 5 0 5 10 15 20 25 30 35 Side length of sensing object d mm Sensing distance x mm Iron Stainless steel Brass Aluminum Copper X d TL T2 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 4 5 5 0 0 5 10 15 20 25 30 35 Side length of sensing object d mm Sensing distance x mm X d Iron Stainless steel Bras...

Page 4: ...Brown 1 Black 4 Blue 3 1 4 3 M8 connector 3 pin Pin Arrangement ON OFF ON OFF Non sensing zone Sensing zone Control output Yellow indicator 100 0 Sensing object Rated sensing distance Load V 0 V Brown 1 Black 4 Blue 3 1 4 3 Main circuit M8 connector 3 pin Pin Arrangement ON OFF NC output ON OFF ON OFF Non sensing zone Sensing zone NO output Yellow indicator 100 0 Sensing object Rated sensing dista...

Page 5: ...onnector 3 pin Pin Arrangement 1 4 3 Main circuit 0 V ON OFF ON OFF Non sensing zone Sensing zone Control output Yellow indicator 100 0 Sensing distance Rated sensing distance V Load Brown 1 Black 4 Blue 3 M8 connector 3 pin Pin Arrangement 1 4 3 Main circuit 0 V ON OFF NC output ON OF ON OFF Non sensing zone Sensing zone NO output Yellow indicator 100 0 Sensing object Rated sensing distance Blue ...

Page 6: ...erwise stated Pre wired Models shielded and non shielded TL T2 E 2M and TL T4M E 2M M8 Connector Models shielded and non shielded TL T2 M5 E and TL T4M M5 E 26 4 5 3 2 4 3 3 4 0 7 6 40 12 4 4 5 16 18 LED insert nut M3 4 3 2 3 3 40 12 26 5 6 16 18 4 0 7 4 4 5 M8 LED insert nut M3 ...

Page 7: ...nected to the Proximity Sensor and load respectively be sure to supply power to the Proximity Sensor before supplying power to the load Effects of Surrounding Metal When mounting the TL T within a metal panel ensure that the clearances given in the following table are maintained Power OFF The Proximity Sensor may output a pulse signal when it is turned OFF Therefore it is recommended that the load...

Page 8: ...ever disassemble or repair the Sensor Environment Water Resistivity The Proximity Sensors are tested intensively on water resistance but in order to ensure maximum performance and life expectancy avoid immersion in water and provide protection from rain or snow Operating Environment Ensure storage and operation of the Proximity Sensor within the given specifications Inrush Current A load that has ...

Reviews: