3-4
Setting the AML File Export
This section provides information on setting the AML file export.
To set the AML file export, from the
File
menu of EPLAN Electric P8, select
Export
–
Project data
–
PLC data
to open the
Export PLC data
dialog box
*1
.
*1. When a menu bar compatible with EPLAN Electric P8 version 2.9 or earlier is displayed, the dialog box can
also be displayed from
Project data
–
PLC
–
Export data
on the menu bar.
To export the controller configuration and device variables from EPLAN Electric P8 to an AML file, be
sure to follow the setting instructions below.
Item
Setting
Configuration project
Select the same value as the
Configuration project
of the target CPU
Unit.
Language
Select the language of the device variable comments to connect.
PLC configuration program
Select
EPLAN Electric P8
Format of export file
Select
AutomationML AR APC V1.2.0
.
Options
Click the
Options
button to open the
Settings: AutomationML AR APC
export
dialog box, and then set the items as follows.
•
Export port-specific interconnection
: Not selected
•
Export accessories
: Selected
•
Export drives
: Not selected
•
Export device-specific configuration values
: Selected
3 Setting EPLAN Electric P8
3-15
Sysmac Studio Electrical CAD Connector Function Practices Guide for AutomationML Import (EPLAN Electric P8) (P156)
3-4
Setting the AML File Export
3