Chapter 2
2-12
CompoWay/F Communications Procedures
Service Response PDU
1.Operating Status
2.Related Information
3.Response Code
Normal Completion
Error Completion
■
Echoback Test
This service performs an echoback test.
Service Request PDU
Service Response PDU
Operating status
Description
00
Operation is being performed (including when operation has stopped automatically
because a protective function has operated).
01
Operation is not being performed.
Response code
Name
Description
0000
Normal completion
No errors were found.
Response code
Error name
Description
1001
Command too long
The command is too long.
2203
Operation error
CPU or EEPROM error
MRC
0
6
2
2
2
4
2
0
1
SRC
Operating
status
Related
information
Response code
7
6
5
4
3
2
1
0
Forward operation
Reverse operation
Protective function operated (when any protective function is ON)
Multifunction output operation (when multifunction output terminal is ON)
Not used.
Not used.
Not used.
Not used.
Bit position
MRC
0
8
2
2
0 to 23
0
1
SRC
Test data
MRC
0
8
2
2
0 to 23
0
1
SRC
4
Response code
Test Data
Summary of Contents for SYSDRIVE 3G3JV
Page 1: ...Cat No I548 E1 01 COMMUNICATIONS MANUAL 3G3JE Compact Simplified Inverters...
Page 14: ...Chapter 1 Communications Methods 1 1 Overview of Communications Methods...
Page 38: ...Chapter 3 Communications Data 3 1 Variable Area Setting Range List 3 2 Status...