Chapter 2
2-16
CompoWay/F Communications Procedures
2-4
Response Code List
Normal Completion
Error Completion
Response code
Name
Description
Error detection
priority
0000
Normal completion
No errors were found.
None
Response code
Name
Description
Error detection
priority
0401
Unsupported command
The service function for the relevant
command is not supported.
1
1001
Command too long
The command is too long.
2
1002
Command too short
The command is too short.
3
1101
Area type error
Wrong variable type
4
1103
Start address out-of-range
error
The read/write start address is out of
range.
5
1104
End address out-of-range
error
The write end address (write start
a number of elements)
exceeds the final address of the vari-
able area.
6
1003
Number of elements/data
mismatch
The amount of data does not match
the number of elements.
7
110B
Response too long
The response exceeds the communi-
cations buffer size (when the number
of elements is larger than 0002).
8
1100
Parameter error
• Bit position is not “00.”
• The write data is out of the setting
range.
• The command code or related infor-
mation in the operation command is
wrong.
9
3003
Read-only error
An attempt was made to write to vari-
able type “C0.”
10
2203
Operation error
• Attempted to write to a parameter in
setup area 1 from setup area 0.
• CPU or EEPROM error
11
Summary of Contents for SYSDRIVE 3G3JV
Page 1: ...Cat No I548 E1 01 COMMUNICATIONS MANUAL 3G3JE Compact Simplified Inverters...
Page 14: ...Chapter 1 Communications Methods 1 1 Overview of Communications Methods...
Page 38: ...Chapter 3 Communications Data 3 1 Variable Area Setting Range List 3 2 Status...