background image



KM2

KM1

+24V

+24V

+24V

+24V

KM1 KM2

PLC etc.

NC

NC

NC

NC

NC

Feedback loop

S14

A2

S24 S44 S54

L1

X1 X2 X3 X4

UA

UB

T11

A1

T12 T21

Y1

Y3

T22

T61 T62

M1

M2

T71

Y2

Y4

T72

T31 T32 T33

T41 T42

OFF

AND

Auto

Manual

G9SX-GS226-T15

Control circuit

+24V

Emergency 

stop switch

Reset Switch

fault non-detect

lamp

lamp

G9SX-BC202

Control circuit

S14

L2

X1 X2

Y1

A1

T33

T32

T22

T11 T12

11

12

21

22

T21

T31

L1

A2

S24

+24V

+24V

PLC etc.

NC

G9SX-SM032(DC24V) <3-phase motor>
+ G9SX-BC202(DC24V) <Emergency stop switch 2ch input / manual reset>
+ G9SX-GS226-T15(DC24V)
<Guard lock safety-door Safety limit switch 2ch input / manual reset>

Inverter

open

A2

ES1

ES2

ES3

X1 X2

T31

A1

T32

Z1 Z2 Z2 Z3 Z4

+24V

PLC etc.

G9SX-SM032

Control circuit

Guard

42

41

12

11

22

21

E1

E2

M

KM2

KM1

Lock release

switch

S6

Guard lock 

Safety-door Switch

U

V

W

Inverter

S3

S2

S1

S5

S4

Note1: This example is corresponding to category 3 (Stop category 2).

Refer to ‘7 Safety Category(EN ISO13849-1) for details.

Note2: Power for the inverter is cut when the motor rotation is detected

in this system with a guard open.
Its response time is an accumulation of G9SX-SM and G9SX-GS.
Determine a safety distance to hazards in view of this response 
time.

Timing chart

Emergency stop S1

Guard lock Safety-

door switch S3

Reset switch S2

Logical AND connection

input T41

Reset switch S5

Safety limit switch S4

KM1, KM2 NC contact

KM1, KM2 NO contact

Inverter operation

(signal for motor)

Lock release signal

Safety Standstill

detection output ES

Standstill detection

input 1 voltage

Standstill detection

input 2 voltage

Lock release switch S6

S1 

KM1, KM2
M

: Emergency switch

S2 

: Reset switch

S3

: Guard lock Safety-door switch

S4

: Safety limit switch

S6

: Lock release switch

S5

: Reset switch

: Contactor
: 3-phase motor

Devices

Motor rotation

Guard open

close

Guard close

open

able to open the guard

rotate with inertia

For protecting the motor against short-circuit

due to incorrect wiring, etc., apply  overcurrent
protective equipments; fuses, circuit-breaker, etc.,
with the ratings below.
Rated voltage: Greater than Standstill detection inputs

(the voltage supplied to the motor)

Rated current: 3A max



When a motor with AC240V or more is used,

connect neutral point of the power supply to earth.

- 9 -

Summary of Contents for Sti G9SX-SM032 Series

Page 1: ...ments Use approved devices with forcibly guided contacts complying with IEC 61810 3 EN 50205 For feedback purpose use devices with contacts capable of switching micro loads of 24VDC 5mA Guard Lock Safety door Switch Use approved devices complying with IEC EN 60947 4 1 auxiliary contact linked with power contact mirror contact For feedback purpose use devices with contacts capable of switching micr...

Page 2: ...s impressed to the standstill detection input and there is a possibility that a high level of noise is superimposed The line of the standstill input must be separately installed from other signal lines 8 Set the time duration of Standstill detection time to an appropriate value that does not cause the loss of safety function of system 9 Tuning mode in User configuration is only for adjusting the S...

Page 3: ...ue can be applied to the Monitoring Mode without having to use the Tuning Mode Functions 1 Use the Operation Preset switch on the back side to select either Standard Configuration or User Configuration The selected configuration mode is enabled at power on Normally please use Standard Configuration which is set as factory default If the Standstill determining time is found too long in the Standard...

Page 4: ...urns on 2 Preset Switches Name Function State Value position of switch Configuration Preset Switch Selects either Standard configuration or User configuration STD Standard configuration default setting USR User configuration Mode Preset Switch Selects either Tuning mode or Monitoring mode in User configuration 3 MON Monitoring mode default setting TUN Tuning mode Standstill determining time Preset...

Page 5: ... Auxiliary outputs control ES1 T31 T32 1 Internal power supply circuit is not isolated 2 Standstill detection inputs are isolated respectively 3 The Safety standstill detection outputs ES1 ES3 are internally redundant respectively 2 2 6 6 100 max 115 max 35 5 max 35 1 Dimensions 4 Type G9SX SM032 Note 1 Above outline drawing is for RC terminal type 1 Typical dimension 2 For RC terminal type only ...

Page 6: ... together and DIN rail Between standstill detection inputs Z1 Z2 Z3 Z4 Between Standstill detection input terminals connected together and Power supply input terminals and other input and output terminals connected together Between Standstill detection input terminals connected together and DIN rail Between all terminals without Standstill detection input terminals connected together and DIN rail ...

Page 7: ...age Standstill detection input 2 voltage Lock release switch S5 S1 KM1 KM2 M Guard lock Safety door Switch S2 Safety Limit Switch S3 Stop signal S4 Reset Switch S5 Lock release switch Contactor 3 phase motor Devices Motor rotation Guard open close Guard close open able to open the guard S4 S2 Note1 This example is corresponding to category 4 Stop category 1 Refer to 7 Safety Category EN ISO13849 1...

Page 8: ...ety door Switch S2 Safety limit switch S3 Stop signal S4 Reset switch S5 Lock release switch Contactor KM3 KM4 Contactor for star delta starter 3 phase motor Devices Motor rotation G9SX SM032 DC24V 3 phase motor with Star Delta wiring G9SX BC202 DC24V Guard lock Safety door switch Safety limit switch 2ch input manual reset S1 Guard lock Safety door Switch S4 Guard open close Guard close open able ...

Page 9: ...rotation is detected in this system with a guard open Its response time is an accumulation of G9SX SM and G9SX GS Determine a safety distance to hazards in view of this response time Timing chart Emergency stop S1 Guard lock Safety door switch S3 Reset switch S2 Logical AND connection input T41 Reset switch S5 Safety limit switch S4 KM1 KM2 NC contact KM1 KM2 NO contact Inverter operation signal f...

Page 10: ... minus to the A2 terminal Wiring of inputs and outputs T31 T32 EDM input KM T31 T32 To turn on Safety standstill detection outputs ON state signals should be input to T32 Otherwise Safety standstill detection outputs will not be turned ON Turns ON OFF according to the state of standstill detection inputs and EDM input Outputs a signal of the same logic as Safety standstill detection outputs Connec...

Page 11: ...etection time preset switches 2 Replace with a new product 1 Check the supply voltage to G9SX units Fault by electro magnetic disturbance or of internal circuits 1 Excessive electro magnetic disturbance 2 Failures of the parts of internal circuits Faults involved with Standstill detection input 1 Faults involved with Standstill detection input 2 Faults involved with Standstill detection input Faul...