Standstill Monitoring Unit
3080529-6 F
Thank you for purchasing G9SX Standstill Monitoring
Unit.
Please read and understand this manual before
using the products.
Keep this manual ready to use whenever needed.
Only qualified person trained in professional
electrical technique should handle G9SX.
Please consult your OMRON representative if you
have any questions or comments.
Make sure that information written in this document
are delivered to the final user of the product.
English
Type G9SX-SM032-
USER'S MANUAL
Safety Precautions
Indicates a potentially hazardous situation
which, if not avoided, will result in minor or
moderate injury, or may result in serious
injury or death.
Additionally there may be significant
property damage.
Meanings of Signal Words
The following signal words are used in this manual.
Alert Statements
Indicates prohibited actions.
Meaning of Alert Symbols
The following alert symbols are used in this manual.
Indicates mandatory actions.
WARNING
Serious injury may possibly occur due to breakdown
of safety outputs.
Do not connect loads beyond the rated value to the
safety outputs.
Serious injury may possibly occur due to loss of
required safety functions.
Wire G9SX properly so that supply voltages or
voltages for loads do NOT touch safety outputs
accidentally or unintentionally.
Serious injury may possibly occur due to loss of
required safety functions.
Do not use G9SX-SM in the system where plurality of
motors are driven by one inverter or contactor.
Serious injury may occur due to failure of safety functions.
Operate the motor at rated G9SX-SM input frequency
(120Hz) or less.
Serious injury may possibly occur due to damages of
safety outputs.
Apply protection circuitry against back electromotive force
in case connecting inductive loads to safety outputs.
Serious injury may possibly occur due to loss of
safety functions.
Use appropriate devices referring to the information
provided below.
WARNING
Controlling
Devices
Relay with
forcibly guided
contacts
Contactor
Other devices
Requirements
Use approved devices with forcibly guided
contacts complying with IEC 61810-3 (EN 50205).
For feedback purpose use devices with contacts
capable of switching micro loads of 24VDC, 5mA.
Guard Lock
Safety-door
Switch
Use approved devices complying with IEC/EN
60947-4-1 auxiliary contact linked with power
contact (mirror contact).
For feedback purpose use devices with contacts
capable of switching micro loads of 24VDC, 5mA.
Evaluate whether devices used are appropriate to
satisfy the requirements of safety category level.
Use approved devices with Direct Opening
Mechanism complying with IEC/EN 60947-5-1,
mechanical lock type and capable of solenoid
coil 24VDC, less than 300mA.
- 1 -
Suitability for Use
Omron Companies shall not be responsible for
conformity with any standards, codes or regulations
which apply to the combination of the Product in the
Buyer’s application or use of the Product. At Buyer’s
request, Omron will provide applicable third party
certification documents identifying ratings and
limitations of use which apply to the Product. This
information by itself is not sufficient for a complete
determination of the suitability of the Product in
combination with the end product, machine, system,
or other application or use. Buyer shall be solely
responsible for determining appropriateness of the
particular Product with respect to Buyer’s application,
product or system. Buyer shall take application
responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION
INVOLVING SERIOUS RISK TO LIFE OR PROPERTY
OR IN LARGE QUANTITIES WITHOUT ENSURING
THAT THE SYSTEM AS A WHOLE HAS BEEN
DESIGNED TO ADDRESS THE RISKS, AND THAT
THE OMRON PRODUCT(S) IS PROPERLY RATED
AND INSTALLED FOR THE INTENDED USE WITHIN
THE OVERALL EQUIPMENT OR SYSTEM.
EU Declaration of Conformity
Standards
OMRON declares that G9SX-SM
is in conformity with
the requirements of the following EU Directives:
EMC Directive 2014/30/EU
Machinery Directive 2006/42/EC
G9SX-SM
is designed and manufactured in accordance
with the following standards:
EN ISO13849-1:2015 Category 4 PL e,
IEC/EN61508 SIL3,
IEC/EN62061 SIL3,
IEC/EN61000-6-2,
IEC/EN61000-6-4,
UL508,
CAN/CSA C22.2 No.142
Original instructions
© OMRON Corporation 2008-2020 All Rights Reserved.