background image

Enclosed Switch

 

SHL

F-45

Lim

it 

Switch

es

Enclosed Switch

SHL

Subminiature Enclosed Switch (Measuring 
48 x 17.5 x 45 mm) with High Sealing 
Property

• Built-in coil spring type basic switch housed in rigid zinc diecast 

alloy casting boasts long life and high precision.

• Requires nearly the same operating force as conventional basic 

precision switches (2.35 to 3.92 N).

• Molded terminal model is available.

• Operation indicator model is also available. 

Model Number Structure

Model Number Legend

Standard Models

1. Actuator

D:

Plunger

Q:

Panel mount plunger

Q22:

Panel mount roller plunger

Q21:

Panel mount crossroller plunger

W:

Short hinge lever

W1:

Hinge lever

W2:

Short hinge roller lever

W21: Hinge roller lever
W3:

One-way action short hinge roller lever

W31: One-way action hinge roller lever

2. Rated Current

None: Standard
01:

Micro Load

Note:

Refer to page 53 for 

Molded Terminal Models.

Ordering Information

List of Models

2

1

SHL-

@

55-

@

Actuator

Standard model

Micro voltage

SHL-D55

SHL-D55-01

SHL-Q55

SHL-Q55-01

SHL-Q2255

SHL-Q2255-01

SHL-Q2155

SHL-Q2155-01

SHL-W55

SHL-W55-01

Plunger

Panel mount plunger

Panel mount roller plunger

Panel mount crossroller plunger

Short hinge lever

Summary of Contents for SHL -

Page 1: ...Standard Models 1 Actuator D Plunger Q Panel mount plunger Q22 Panel mount roller plunger Q21 Panel mount crossroller plunger W Short hinge lever W1 Hinge lever W2 Short hinge roller lever W21 Hinge...

Page 2: ...ay action hinge roller lever Agency Standard File No UL UL508 E76675 CSA CSA C22 2 No 14 LR45746 T V Rheinland EN60947 5 1 R9451332 Rated voltage Carry current Current Volt amperes Make Break Make Bre...

Page 3: ...tate current Micro Voltage Current Load Model Rated voltage Non inductive load Inductive load Inrush current Resistive load Lamp load Inductive load Motor load NC NO NC NO NC NO NC NO NC NO 125 VAC 10...

Page 4: ...e 1 000 VAC max 300 VDC max EN60947 5 1 Pollution degree operating environment 3 EN60947 5 1 Short circuit protective device SCPD 10 A fuse type gG IEC269 Conditional short circuit current 100 A EN609...

Page 5: ...M 1 2 NC 4 NO EN60947 5 1 Ambient temperature 5 C to 35 C Ambient humidity 40 to 50 Durability x 10 4 operations Switching current A Operating frequency 30 operations min cos 1 250 VAC Movable plunger...

Page 6: ...tainless steel pin plunger 9 6 15 15 16 9 7 8 dia see note Note Stainless steel pin plunger Panel Mount Plunger SHL Q55 SHL Q55 01 M14 1 Two hexagon nut thickness 2 5 width 17 9 6 15 15 16 9 11 dia 4...

Page 7: ...6 16 5 0 2 9 6 16 17 5 15 15 Hinge Lever SHL W155 SHL W155 01 Note Stainless steel lever t 1 see note 53R OP FP 13 24 3 5 16 9 9 6 16 6 8 21 16 15 15 16 5 0 2 Note Sintered stainless roller Short Hing...

Page 8: ...One way Action Short Hinge Roller Lever SHL W355 SHL W355 01 9 5 dia 4 8 see note OP FP 35 5R Operating direction 13 24 3 5 16 9 9 6 16 6 8 21 16 15 15 16 5 0 2 90 Note Stainless sintered roller One...

Page 9: ...and or EN IEC approved models are available The molded terminal model may be equipped with an operation indicator neon lamp or LED upon request to facilitate maintenance and inspection The operation i...

Page 10: ...tion rubber packing will deform and thus affect the sealing capability Mounting Secure the Switch with two M4 screws and washers The tightening torque applied to each terminal must be 1 18 to 1 37 N m...

Page 11: ...lowing diagram The above diagram is for standard conditions 5 C to 35 C 40 to 70 Since the values vary depending on the operating environ ment conditions contact your OMRON representative for further...

Page 12: ...t of product improvement specifications are subject to change without notice ALL DIMENSIONS SHOWN ARE IN MILLIMETERS To convert millimeters into inches multiply by 0 03937 To convert grams into ounces...

Reviews: