background image

4

Switch Mode Power Supply 

S8VM

Note: 1. Do not use the Inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of

the Power Supply may result in ignition or burning.

2. Refer to the Engineering Data section on page 15 to 17 for details.
3. If the V. ADJ adjuster is turned, the voltage will increase by more than +20% of the voltage adjustment range. When adjusting the output voltage, confirm the

actual output voltage from the Power Supply and be sure that the load is not damaged.

4. To reset the protection, turn OFF the input power for three minutes or longer and then turn it back ON. Alternatively, turn OFF the remote control signal and

then turn it back ON again. 

5. Conducted emissions: The noise value is affected by factors such as the wiring method. The Power Supply conforms to Class B when the aluminum plate

is laid under the Power Supply. For 600-W models, insert a clamp filter (ZCAT3035-1330 by TDK: 100 

 min. [50 to 500 MHz], or the equivalent) in the input

wire, and ring core (HF60T38X14X22 by TDK: 16 

 typ. [1 MHz], 46 

 typ. [10 MHz] , or the equivalent) in the output wire to reduce noise

6. Radiated emissions: The noise value is affected by factors such as the wiring method. The Power Supply conforms to Class A when the aluminum plate is

laid under the Power Supply (1,500-W models).

7. The measuring method conforms to JEITA standard RC-9131A. Refer to Ripple under Safety Precautions on page 34.
8. The Power Supply will not conform to safety standards if the customer replaces the fan. 

Item

Power rating

300 W

600 W

1,500 W

Efficiency

5-V models

77% min.

77% min.

---

12-V models

78% min.

79% min.

---

15-V models

79% min.

80% min.

---

24-V models

81% min.

81% min.

82% min.

Input

Voltage (See note 1.)

100 to 240 VAC (85 to 264 VAC)

100 to 240 VAC (85 to 265 VAC)

Frequency (See note 1.)

50/60 Hz (47 to 63 Hz)

Current

100-V input

4.0 A max. (5 V)
4.3 A max. (12 V, 15 V, and 24 V)

8.0 A max. (5 V)
8.3 A max. (12 V, 15 V, and 24 V)

20.0 A max.

200-V input

2.0 A max. (5 V)
2.2 A max. (12 V, 15 V, and 24 V)

4.0 A max. (5 V)
4.2 A max. (12 V, 15 V, and 24 V)

11.0 A max.

Power factor

100-V input

0.98 min.

0.97 min.

200-V input

0.94 min.

0.93 min.

Harmonic current emissions

Conforms to EN61000-3-2

Leakage current

100-V input

0.4 mA max.

1.5 mA max.

200-V input

0.75 mA max.

1.5 mA max.

Inrush current 
(See note 2.)

100-V input

20 A max. (for cold start at 25

°

C)

200-V input

40 A max. (for cold start at 25

°

C)

Output

Voltage adjustment range (See note 3.)

20% to 20% (with V. ADJ)

Ripple

3.8% (p-p) max. (5 V), 2.0% (p-p) max. (12 V), 2.0% (p-p) max. (15 V),
1.25% (p-p) max. (24 V), (at rated input/output voltage)

1.25% (p-p) max. (See note 7.),
(at rated input/output voltage)

Input variation influence

0.4% max. (at 85 to 264 VAC input, 100%)

Load variation influence (rated input voltage)

0.6% max. (with rated input, 0 to 100% load)

Temperature variation influence

0.02%/

°

C max.

Start up time (See note 2.)

1,000 ms max. (at rated input/output voltage)

Hold time (See note 2.)

20 ms typ. (15 ms min.) (at rated input/output voltage)

Additional 
functions

Overload protection (See note 2.)

105% to 160% of rated load current (5 V, 12 V, and 15 V), 120% to 160% of rated 
load current (S8VM-30024C), 115% to 160% of rated load current (S8VM-
60024C), voltage drop (12 V, 15 V, and 24 V), voltage drop, intermittent (5 V), 
automatic reset

105% to 160% of rated load current (100 VAC),
155% to 200% of rated load current (200 VAC),
voltage drop, automatic reset (Turns OFF 
when continuous for 5 s min.) (See note 4.)

Overvoltage protection (See note 2.)

Yes (See note 4.)

Overheat protection (See note 2.)

Yes (See note 4.)

Undervoltage alarm indication

No

Undervoltage alarm output

No

Power failure alarm indication

Yes (color: red)

Power failure alarm output

Yes (Transistor output), 30 VDC max., 50 mA max.

Series operation

Yes

Parallel operation

Yes (Up to 2 units)

Remote sensing function

Yes

Remote control function

Yes

Other

Ambient operating temperature

Refer to the derating curve in Engineering Data (300-W, 600-W, 1,500-W Models). (with no icing or condensation) (See note 2.)

Storage temperature 

25 to 65

°

C

Ambient operating humidity

30% to 85% (Storage humidity: 25% to 90%)

Dielectric strength

3.0 kVAC for 1 min. (between all inputs and outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and PE terminals; detection current: 20 
mA)
500 VAC for 1 min. (between all outputs and PE terminals; detection current: 100 
mA)
100 VAC for 1 min. (between all outputs and RC terminals; detection current: 100 
mA)
500 VAC for 1 min. (between all outputs and PF terminals; detection current: 20 
mA)

3.0 kVAC for 1 min. (between all inputs and 
outputs; detection current: 20 mA)
2.0 kVAC for 1 min. (between all inputs and FG 
terminals; detection current: 20 mA)
500 VAC for 1 min. (between all outputs and 
FG terminals; detection current: 300 mA)
100 VAC for 1 min. (between all outputs and 
RC terminals; detection current: 100 mA)
500 VAC for 1 min. (between all outputs and 
PF terminals; detection current: 20 mA)

Insulation resistance

100 M

 min. (between all outputs and all inputs, PE terminals) at 500 VDC

100 M

 min. (between all outputs and all in-

puts, FG terminals) at 500 VDC

Vibration resistance

10 to 55 Hz, 0.375-mm single amplitude for 2 hours each in X, Y, and Z directions 10 to 55 Hz, 0.15-mm single amplitude for 2 

hours each in X, Y, and Z directions

Shock resistance

150 m/s

2

, 3 times each in 

±

X, 

±

Y, 

±

Z directions

Output indicator

Yes (color: green) 

EMI

Conducted Emission

Conforms to EN61204-3 EN55011 Class B and based on FCC Class B

Conforms to EN61204-3 EN55011 Class A 
and based on FCC Class A

Radiated Emission

Conforms to EN61204-3 EN55011 Class B

Conforms to EN61204-3 EN55011 Class A

EMS 

Conforms to EN61204-3 High severity levels

Approved standards (See note 8.)

UL: UL508 (Recognition) (5 V, 12 V, and 15 V)
UL508 (Listing) (24 V), UL60950-1
UL1604 (Class 

I

/Division 2, Listing) (24 V) (pending)

CSA: cUL: C22.2 No.14, cUR: CSA No. 60950-1
EN: EN50178, EN60950-1
SEMI-F47 (200 VAC input)

UL: UL508 (Recognition), UL60950-1
cUR: CSA C22.2 No.14, No. 60950-1
EN: EN50178, EN60950-1
SEMI-F47 (200 VAC input)

Weight

1,100 g max.

1,700 g max.

3,800 g max.

Summary of Contents for S8VM Series

Page 1: ...d 1 500 W models Finger protection prevents electric shock DIN Rail mounting Model Number Structure Model Number Legend Note Not all combinations are possible Please refer to the list of models in Ord...

Page 2: ...e 2 S8VM 15005D See note 2 12 V 12 5 A S8VM 15012 S8VM 15012D 15 V 10 A S8VM 15015 S8VM 15015D 24 V 6 5 A S8VM 15024 S8VM 15024D Covered type 15 W 100 to 240 VAC 5 V 3 A S8VM 01505C S8VM 01505CD 12 V...

Page 3: ...max 15 V 1 0 p p max 24 V at rated input output voltage 3 2 p p max 5 V 1 5 p p max 12 V 1 2 p p max 15 V 0 75 p p max 24 V at rated input output voltage Input variation influence 0 4 max at 85 to 26...

Page 4: ...t voltage Hold time See note 2 20 ms typ 15 ms min at rated input output voltage Additional functions Overload protection See note 2 105 to 160 of rated load current 5 V 12 V and 15 V 120 to 160 of ra...

Page 5: ...ircuit Rectifier smoothing circuit Drive control circuit Photocoupler Voltage detection circuit Rectification Smoothing Inrush current protection circuit Overcurrent detection circuit S8VM 030 30 W Fu...

Page 6: ...otection circuit Noise filter Overvoltage detection circuit Rectifier smoothing circuit Drive control circuit Photocoupler Voltage detection circuit Rectification Smooth ing Harmonic current suppressi...

Page 7: ...balance circuit Output voltage monitor Overvoltage detection circuit Voltage detection circuit S8VM 600 C 600 W PF E FG PF Alarm PF C INPUT AC N AC L DC OUTPUT V V V V S S CBG CB RC RC Fan Drive Powe...

Page 8: ...50 C S8VM 05024A P 300 W 600 W 1 500 W Models Note Refer to page 14 No Name Function 1 AC input terminals L N Connect the input lines to these terminals See note 1 2 PE terminal Protective earthing te...

Page 9: ...tandard Mounting Horizontal Mounting Face up Mounting 50W Standard Mounting Horizontal Mounting Face up Mounting 100W Standard Mounting Horizontal Mounting Face up Mounting 150W Standard Mounting Hori...

Page 10: ...Across the load terminals 2 Between the S terminal and terminal 3 Between the S terminal and terminal Select the capacity of the connected capacitor from be tween several tens to several hundreds of F...

Page 11: ...age alarm function the DC LOW indicator will light to notify of an output error The transistor also sends an output externally to notify of the error except for the S8VM 01524A and S8VM 03024A Transis...

Page 12: ...tatus 2 OFF ON Normal approx 90 min of rated output voltage The output voltage has re covered to normal status following a previous sud den voltage drop 3 ON OFF Output drop approx 90 max of rated out...

Page 13: ...g the output voltage adjuster V ADJ To clear DC LOW1 LED display and transistor output status turn OFF the input power and wait at least 60 s be fore turning ON the input power again The overload stat...

Page 14: ...lor label identifying output voltage Green 5 V Blue 12 V Yellow 15 V White 24 V No Name Function 1 AC input terminal L N Connect the input lines to these terminals See note 1 2 PE terminal Protective...

Page 15: ...posite side 4 Mounting screw tightening torque recommended value M4 1 27 N m The screws must not protrude more than 6 mm inside the Power Supply Remote Sensing Function This function is used to compen...

Page 16: ...he alarm is also output externally by a transistor Transistor output 30 VDC max 50 mA max Residual voltage when ON 2 V max Leakage current when OFF 0 1 mA max Alarm detection voltage Approx 80 of outp...

Page 17: ...y be deteriorated or damaged 2 The internal parts may possibly be deteriorated or dam aged Do not use the Power Supply for applications where the load causes frequent inrush current and overload 100 m...

Page 18: ...on The overheat protection circuit will operate and outputs will be shut OFF to protect the Power Supply if the ambient temperature rises the fan stops or other errors cause the Power Supply s interna...

Page 19: ...24A Note The image is the S8VM 01524 Model Mounting Holes Bottom View Side Mounting Bottom Mounting 62 0 5 68 0 5 Two 4 dia 67 0 3 Two 4 dia Note The image is the S8VM 01524A Model 84 5 33 5 13 6 max...

Page 20: ...ng Bottom Mounting 97 0 5 68 0 5 Two 4 dia 83 0 5 8 0 2 15 0 2 Three 4 dia Note The image is the S8VM 05024A Model 82 5 17 6 max 160 5 8 5 0 5 68 0 5 135 0 5 120 0 5 8 5 0 5 15 0 2 7 5 0 2 25 0 2 30 0...

Page 21: ...max 160 5 135 0 5 8 5 0 5 8 5 0 5 68 0 5 37 5 82 5 25 0 5 7 5 0 2 120 0 5 15 0 2 26 5 0 2 Three M3 depth 4 max Two M3 depth 8 max S8VM 150 S8VM 150 C S8VM 15024A S8VM 15024P Note The image is the S8V...

Page 22: ...5 1 3 5 max 14 5 4 Sliding 9 max S8VM 015 D S8VM 015 CD S8VM 01524AD Note The image is the S8VM 01524D Model Note The image is the S8VM 01524AD Model 33 17 6 max 3 5 max 14 82 5 4 Sliding 9 max 105 4...

Page 23: ...VM 050 CD S8VM 05024AD S8VM 05024PD Note The image is the S8VM 05024D Model Note The image is the S8VM 05024AD Model 33 17 6 max 3 5 max 14 82 5 5 4 Sliding 9 max 170 4 160 5 36 6 14 164 5 46 2 84 5 1...

Page 24: ...5 max 14 5 4 Sliding 9 max 170 4 160 5 82 5 39 1 15 max 164 5 14 174 4 46 2 84 5 5 4 Sliding 9 max 45 6 3 5 max S8VM 150 D S8VM 150 CD S8VM 15024AD S8VM 15024PD Note The image is the S8VM 15024D Mode...

Page 25: ...0 5 Four M4 depth 6 max Four M4 depth 6 max 260 0 5 46 max 10 260 0 5 10 M8 See note 126 5 82 60 0 5 11 7 25 112 0 5 327 max Four M4 depth 6 max Four M4 depth 6 max S8VM 300 C Note The image is the S...

Page 26: ...I horizontal bottom mounting for 600 W models S82Y VM60S Mounting Bracket J front mounting for 600 W models S82Y VM60F Mounting Bracket K DIN Rail mounting for 600 W models S82Y VM60D 150 35 20 0 5 7...

Page 27: ...es for 100 W models e Mounting holes for 150 W models A B B B A A S82Y VM10F Using the Mounting Bracket Screws Used A Accessories Use the enclosed screws in two places for 15 W 30 W and 50 W models an...

Page 28: ...ing the Mounting Bracket Screws Used A Accessories Use the enclosed screws in four places B M4 three places Mounting screw tightening torque recom mended 1 27 N m A A A A B B B 60 4 5 Two 4 5 dia 48 6...

Page 29: ...d screws in four places Mounting screw tightening torque recommended 1 27 N m B A A A A B B 6 202 8 215 100 72 Three 4 5 dia S82Y VM60B Using the Mounting Bracket Screws Used A Accessories Use the enc...

Page 30: ...3 A A A A B B B S82Y VM60F Using the Mounting Bracket Screws Used A Accessories Use the enclosed screws in four places B M4 three places Mounting screw tightening torque recommended 1 27 N m A A A A...

Page 31: ...sing S82Y VM30C Replacement Fan Unit for 300 W Models S82Y VM30FAN Replacement Fan Unit for 600 W Models S82Y VM60FAN Replacement Fan Unit for a 1 500 W Model S82Y VM15FAN 3 000 50 AWG24 XHP 3 Manufac...

Page 32: ...ground completely A protective earthing connection stipulated in safety standards is used Electric shock or malfunction may occur if the ground is not connected completely Minor fire may possibly occu...

Page 33: ...bient Operating and Storage Environments Store the Power Supply at a temperature of 25 to 65 C and a humidity of 25 to 90 The Internal parts may occasionally be deteriorated or damaged Do not use the...

Page 34: ...voltage alarm function may operate Ripple S8VM 15224C Only The rated ripple noise voltage was measured using a measuring cir cuit that conforms to the JEITA standard RC 9131A Remote Sensing Function 1...

Page 35: ...ad is in overload status or is short circuited Remove the load wires when checking Attempt to clear the overvoltage protection function Turn OFF the input power once and leave it OFF for at least 3 mi...

Page 36: ...sibility of OMRON for any act exceed the individual price of the product on which liability is asserted IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY REPAIR OR OTHER CLAIMS REGARDING THE PRODUCT...

Reviews: