S8VK-WA/S8VK-WB

24

S8VK-W

A

S8VK-WB

Common Accessories

Common Precautions

Safety Precautions

Warning Indications

Meaning of Product Safety Symbols

Product failure may result in fire or electric shocks.
Be sure to use the recommended circuit breaker or 
fuse. For details, refer to 

Recommended circuit 

breakers and fuses

 on page 25.

The electrical wire may come out and an electric shock 
may be caused. Insert the solid wire or ferrule straight into 
the terminal block until the end touches the terminal block.

Minor electric shock, fire, or Product failure may 

occasionally occur. Do not disassemble, modify, or repair 

the Product or touch the interior of the Product.

Minor burns may occasionally occur. Do not touch 
the Product while power is being supplied or 
immediately after power is turned OFF.

Minor injury due to electric shock may occasionally 
occur. Do not touch the terminals while power is 
being supplied.

Minor electric shock, fire, or Product failure may occasionally 
occur. Do not allow any pieces of metal, conductors, or 
cuttings from installation work to enter the Power Supply.

If the circuit breaker has tripped, or the fuse has 
blown, there could be a severe failure in the Power 

Supply. Do not turn the input ON again.

Ambient Operating and Storage Environments

• Store the Power Supply at a temperature of -40 to +85°C and a 

humidity of 95% or less.

• Do not use the Power Supply in areas outside the derating curve 

as doing so may result in internal parts occasionally deteriorating 
or being damaged.

• Use the Power Supply at a humidity of 95% max.
• Do not use the Power Supply in locations subject to direct sunlight.
• Do not use locations where liquids, foreign matter, or corrosive 

gases may enter the interior of the Product.

Installation Environment

• Do not use the Product in locations subject to shocks or vibrations. 

In particular, install the Power Supply as far away as possible from 
contactors or other devices that are a vibration source.

• Install the Power Supply well away from any sources of strong, 

high-frequency noise and surge.

• Do not use an inverter output for the product. Inverters with an 

output frequency of 50/60 Hz are available, but the rise in the 
internal temperature of the product may result in ignition or 
burning. 

• If the input is connected to a UPS, do not connect a UPS with a 

square-wave output. Doing so will cause the internal temperature 
of the product to increase, possibly causing smoking or burning.

Mounting

• Take adequate measures to ensure proper heat dissipation to 

increase the long-term reliability of the Power Supply.
Be sure to allow convection in the atmosphere around devices 
when mounting. Do not use in locations where the ambient 
temperature exceeds the range of the derating curve.

• When cutting out holes for mounting, make sure that cuttings do 

not enter the interior of the Power Supplies.

• The internal parts may occasionally deteriorate and be broken due 

to adverse heat radiation. Do not loosen the screws on the Power 
Supply.

• S8VK-W can be used in combinations with a horizontal separation 

of less than 15 mm (front, side-by-side mounting) only in cases of 
the same model being used.
In such cases, use the product in accordance with a derating curve 
with a horizontal separation of less than 15 mm.

Indicates a potentially hazardous situation 

which, if not avoided, will result in minor or 

moderate injury, or may result in serious 

injury or death. Additionally, there may be 

significant property damage.
Indicates a potentially hazardous situation 

which, if not avoided, may result in minor or 

moderate injury or in property damage.

Precautions for 

Safe Use

Supplementary comments on what to do or 

avoid doing, to use the product safely.

Precautions for 

Correct Use

Supplementary comments on what to do or 

avoid doing, to prevent failure to operate, 

malfunction or undesirable effect on product 

performance.

Caution against electric shock

Used to warn of the risk of electric shock under 

specific conditions.

Caution against high temperatures

Used to warn of the risk of minor injury caused by 

high temperatures.

No disassembly

Use to indicate prohibition when there is a risk of 

minor injury from electrical shock or other source if 

the product is disassembled.

General instructions

Used for general mandatory action precautions for 

which there is no specified symbol.

WARNING

CAUTION

WARNING

CAUTION

Precautions for Safe Use

*

2

*

2

*

1

*

3

*

3

*

1

*

1

*

1

*

1

*

1

*1.

Convection of air

*2.

Vertical separation: 23 

mm or more

*3.

Horizontal separation: 

15mm or more

(Standard mounting)

Horizontal separation: 

Less than 15 mm

(Front, side-by-side 

mounting)

(B) Face-up mounting

(A) Standard (Vertical) 

mounting

(C) Front, Side-by-side 

mounting

Summary of Contents for S8VK-W Series

Page 1: ... 40 to 70 C 1 Side by side Mounting enabled 1 2 Complies with SEMI F47 0706 standard 3 Certification for 3 000 m altitude 3 Coated PCBs for Better Resistance to Environment Equipped with signal output that indicates DC OK and the overload status Five years Warranty 1 For details refer to Derating Curves on page 9 and 20 2 Refer to the Front Side by side mounting on page 24 3 For details refer to S...

Page 2: ... Model Number Legend Not all combinations are possible Refer to List of Models in Ordering Information below 1 Rated input voltage 2 Power rating 3 Output voltage Ordering Information List of Models Accessories Order separately Refer to page 22 for S8VK WA S8VK WB Common Accessories Output voltage Power rating 240 W 480 W 960 W 24 V Released Released Released Refer to Safety Precautions on page 24...

Page 3: ...s typ Additional functions Overload protection Yes automatic reset intermittent operation type Refer to Overload Protection on page 5 Overvoltage protection Yes 130 or higher of rated output voltage power shut off shut off the input voltage and turn on the input again Refer to Overvoltage Protection on page 5 Series operation Yes For up to two Power Supplies external diodes required Parallel opera...

Page 4: ...iance To comply with PELV output requirements for EN IEC 60204 1 ground the negative side of the output V to a protective earth PE EN IEC 61558 2 16 The S8VK WA was designed based on EN IEC 61558 2 16 Currently IEC 61558 2 17 has been replaced by IEC 61558 2 16 When certification was received for EN IEC 60204 1 Machinery Safety it was necessary to go through a control transformer to the control ci...

Page 5: ... output voltage is more than 90 of the rated output voltage and the internal MOS FET relay is conducted turned ON Note 1 The output voltage may be generated even if the indicator does not light Be sure to check the output voltage when connecting to the load 2 This function monitors the voltage at the power output terminals To check the voltage accurately measure the voltage at the load end 3 If th...

Page 6: ...cuiting change to a product with less load or larger output capacity z z The product may have failed or the overvoltage protection may have been activated for the product To check for overvoltage protection turn the input power OFF and then turn it ON again after 3 minutes or more has elapsed If no output voltage is output the product may have failed Replace the product No input voltage is being s...

Page 7: ...tection circuit Smoothing circuit Harmonic current suppression circuit DC OK COM DC OUTPUT L1 1 INPUT L1 2 L2 1 L2 2 L3 2 L3 1 out I 100 S8VK WA48024 480 W S8VK WA96024 960 W Overcurrent detection circuit Current detection circuit Smoothing circuit Harmonic current suppression circuit Rectifier Noise Filter Photocoupler Inrush current protection circuit Drive control circuit Overcurrent circuit V1...

Page 8: ...se terminals 9 V2 10 V1 11 V2 12 V3 13 INPUT OK Indicator INPUT OK Green Lights up when the input voltage exceeds the lower limit value of the permissible range 14 Iout 100 Indicator Iout 100 Yellow The Iout 100 Indicator lights up when the output current exceeds the rated output current 15 DC OK Indicator DC OK Green Lights up when the output voltage is more than 90 of the rated output voltage 16...

Page 9: ...shaded area time is required to reach the rated output voltage after the input voltage is applied A Standard mounting B Face up mounting C Front side by side mounting This Power Supply can be used at an altitude of up to 3 000 m Between 2 000 and 3 000 m derate the load according to the following derating curve 240 W 480 W 960 W Horizontal separation 15 mm or more 240 W 480 W 960 W Horizontal sepa...

Page 10: ... 54 4 53 8 5 4 6 5 0 55 19 8 1 2 0 6 121 4 1 55 1 0 6 124 1 10 S8VK WA24024 5 2 8 0 max when sliding 121 4 1 0 6 0 6 1 1 1 10 20 8 7 5 0 9 5 17 3 52 7 53 8 117 111 4 124 1 5 4 6 5 0 55 19 8 65 1 S8VK WA48024 5 17 3 51 1 53 8 121 4 1 117 111 4 0 6 0 6 124 1 1 1 1 10 5 4 6 5 0 55 19 8 118 1 47 2 10 0 9 5 2 8 0 max when sliding S8VK WA96024 ...

Page 11: ... operate at an ambient temperature of 40 to 70 C 1 Side by side Mounting enabled 1 2 Complies with SEMI F47 0706 standard 3 Certification for 3 000 m altitude 3 Coated PCBs for Better Resistance to Environment Equipped with signal output that indicates DC OK and the overload status 1 For details refer to Derating Curves on page 20 2 Refer to the Front Side by side mounting on page 24 3 For details...

Page 12: ...960 W 24 V Released Released Released 48 V Released Released Released S8VK WB Series name 2 3 1 Code Rated input voltage B 380 to 480 Code Power rating 240 240 W 480 480 W 960 960 W Code Output voltage VDC 24 24 V 48 48 V Power rating Rated input voltage Rated output voltage VDC Rated output current Maximum boost current Model 240 W Three phase two phase 380 to 480 VAC Allowable range Three phase ...

Page 13: ...f shut off the input voltage and turn on the input again Refer to Overvoltage Protection on page 16 Series operation Yes For up to two Power Supplies external diodes required Parallel operation Yes For up to two Power Supplies Refer to Parallel Operation on page 28 INPUT OK Indicator Yes LED Green DC OK Indicator Yes LED Green Iout 100 Indicator Yes LED Yellow DC OK Signal Output Yes MOS FET relay...

Page 14: ...d turn on the input again Refer to Overvoltage Protection on page 16 Series operation Yes For up to two Power Supplies external diodes required Parallel operation Yes For up to two Power Supplies Refer to Parallel Operation on page 28 INPUT OK Indicator Yes LED Green DC OK Indicator Yes LED Green Iout 100 Indicator Yes LED Yellow DC OK Signal Output Yes MOS FET relay output 30 VDC max 50 mA max Io...

Page 15: ...r the input voltage is input 11 MTBF is calculated according to JEITA RCR 9102 12 Refer to Recommended Replacement Periods and Periodic Replacement for Preventive Maintenance on page 32 for details 13 When using 2 phase input conforms to EN 61000 3 2 under the following condition 960W At the rated output voltage and 80 or less than the rated output current 14 Refer to Standard Compliance below for...

Page 16: ... output voltage is more than 90 of the rated output voltage and the internal MOS FET relay is conducted turned ON Note 1 The output voltage may be generated even if the indicator does not light Be sure to check the output voltage when connecting to the load 2 This function monitors the voltage at the power output terminals To check the voltage accurately measure the voltage at the load end 3 If th...

Page 17: ...cuiting change to a product with less load or larger output capacity z z The product may have failed or the overvoltage protection may have been activated for the product To check for overvoltage protection turn the input power OFF and then turn it ON again after 3 minutes or more has elapsed If no output voltage is output the product may have failed Replace the product No input voltage is being s...

Page 18: ...suppression circuit Smoothing circuit Rectifier smoothing circuit Signal Output Signal Output Current detection circuit Overcurrent detection circuit Voltage detection circuit Overvoltage detection circuit Photocoupler Drive control circuit Overcurrent circuit V1 V2 V1 V3 V2 DC OUTPUT COM DC OK L1 1 L1 2 L2 1 L2 2 L3 1 L3 2 INPUT I 100 out ...

Page 19: ...erminals 9 V2 10 V1 11 V2 12 V3 13 INPUT OK Indicator INPUT OK Green Lights up when the input voltage exceeds the lower limit value of the permissible range 14 Iout 100 Indicator Iout 100 Yellow The Iout 100 Indicator lights up when the output current exceeds the rated output current 15 DC OK Indicator DC OK Green Lights up when the output voltage is more than 90 of the rated output voltage 16 Out...

Page 20: ...ote 1 Apply the rated input voltage for both three phase and two phase 2 In the shaded area time is required to reach the rated output voltage after the input voltage is applied A Standard mounting B Face up mounting C Front side by side mounting This Power Supply can be used at an altitude of up to 3 000 m Between 2 000 and 3 000 m derate the load according to the following derating curve 240 W 4...

Page 21: ...5 8 54 4 53 8 5 4 6 5 0 55 19 8 1 2 0 6 121 4 1 55 1 0 6 124 1 10 S8VK WB240 5 2 8 0 max when sliding 121 4 1 0 6 0 6 1 1 1 10 20 8 7 5 0 9 5 17 3 52 7 53 8 117 111 4 124 1 5 4 6 5 0 55 19 8 65 1 S8VK WB480 5 17 3 51 1 53 8 121 4 1 117 111 4 0 6 0 6 124 1 1 1 1 10 5 4 6 5 0 55 19 8 118 1 47 2 10 0 9 5 2 8 0 max when sliding S8VK WB960 ...

Page 22: ...eparately DIN Rail Mounting Parts Order Separately Accessories Order separately Product name Model Front Mounting Bracket for 240 W S82Y VKW20F Front Mounting Bracket for 480 W S82Y VKW40F Front Mounting Bracket for 960 W S82Y VKW90F Part name Model Support Rail Aluminum PFP 100N PFP 50N PFP 100N2 End Plate PFP M ...

Page 23: ...nit Name Model Dimensions Appearance Front mounting bracket For 240 W models S82Y VKW20F Front mounting bracket For 480 W models S82Y VKW40F Front mounting bracket For 960 W models S82Y VKW90F Two 4 5 dia 0 1 35 0 1 40 R1 5 35 7 3 1 40 25 t 1 2 55 Two 4 5 dia 0 1 35 0 1 35 40 40 25 7 3 t 1 2 R1 5 1 65 118 106 85 0 1 1 R1 5 Three 4 5 dia 0 1 35 40 7 3 25 t 1 2 Mounting Rail Material Aluminum PFP 10...

Page 24: ...gnition or burning If the input is connected to a UPS do not connect a UPS with a square wave output Doing so will cause the internal temperature of the product to increase possibly causing smoking or burning Mounting Take adequate measures to ensure proper heat dissipation to increase the long term reliability of the Power Supply Be sure to allow convection in the atmosphere around devices when m...

Page 25: ...ion Be sure to remove the sheet covering the S8M for machining before power ON so that it does not interfere with heat dissipation If there is a possibility of vibration or shock please use wires and stranded wires with ferrules Minor fire may occasionally occur Always check the voltage of the equipment when replacing the Unit and be sure to use a conforming product Use the following material for ...

Page 26: ...d protection function When this happens the Iout 100 indicator will blink in accordance with the intermittent operation and the Iout 100 signal output will repeatedly turn ON and OFF The shortest ON time of the Iout 100 signal output during intermittent operation is 5 ms Specifications of the Signal Output Terminals between DC OK Signal Output Terminal and COM Terminal and between Iout 100 Signal ...

Page 27: ...g ratings 2 Though Power Supplies having different specifications can be connected in series the current flowing through the load must not exceed the smaller rated output current Be sure to check that the Iout 100 indicator is not lit or the Iout 100 signal output is turned OFF before using Making Positive Negative Outputs The outputs are floating outputs i e the primary circuits and secondary cir...

Page 28: ...D1 and D2 Also the diodes will cause a power loss equivalent to the Power Supply output current IOUT times the diode forward voltage VF Therefore cooling measures must be implemented so that the temperature of the diodes decreases to the catalog value or lower Because of the load power and power loss due to the diodes do not exceed the rated power of one Power Supply rated output voltage rated out...

Page 29: ...rewdriver still inserted into the release hole insert the wire into the terminal hole until it strikes the terminal block 3 Remove the flat blade screwdriver from the release hole Checking Connections After the insertion pull gently on the wire to make sure that it will not come off and the wire is securely fastened to the terminal block The insulation distance is still satisfied although some of ...

Page 30: ... mm2 AWG Phoenix Contact Weid muller Wago 0 25 24 8 10 AI 0 25 8 H0 25 12 FE 0 25 8N YE 10 12 AI 0 25 10 0 34 22 8 10 AI 0 34 8 H0 34 12 FE 0 34 8N TQ 10 12 AI 0 34 10 0 50 20 8 10 AI 0 5 8 H0 5 14 FE 0 5 8N WH 10 12 AI 0 5 10 H0 5 16 FE 0 5 10N WH 0 75 18 8 10 AI 0 75 8 H0 75 14 FE 0 75 8N GY 10 12 AI 0 75 10 H0 75 16 FE 0 75 10N GY 1 1 25 18 17 8 10 AI 1 8 H1 0 14 FE 1 0 8N RD 10 12 AI 1 10 H1 0...

Page 31: ...d The internal protection may operate if a large amount of surge voltage such as a lightning inrush is applied to the input In case there is no output voltage please check the following points before contacting us Checking overload protected status Check whether the load is in overload status or is short circuited Remove the load wires when checking Can be checked depending on whether or not the I...

Page 32: ...Supply depends on the correct operation of these components to achieve the original Power Supply functions and performance However the influence of the ambient temperature on aluminum electrolytic capacitors is large and the service life is reduced by half for each 10 C rise in temperature Arrhenius law When the capacity reduction life of the electrolytic capacitor is reached the Power Supply fail...

Page 33: ...UARTERS Chicago IL USA 847 843 7900 800 556 6766 automation omron com Controllers I O Machine Automation Controllers MAC Motion Controllers Programmable Logic Controllers PLC Temperature Controllers Remote I O Robotics Industrial Robots Mobile Robots Operator Interfaces Human Machine Interface HMI Motion Drives Machine Automation Controllers MAC Motion Controllers Servo Systems Frequency Inverters...

Reviews: