Safety Precautions for All Power Supplies

.

Minor electric shock, fire, or Product failure may 
occasionally occur. Do not disassemble, modify, or 
repair the Product to touch the interior of the 
Product. 

Minor burns may occasionally occur. Do not touch 
the Product while power is being supplied or 
immediately after power is turned OFF. 

Fire may occasionally occur. Tighten terminal screws 
to the specified torque of 1.13 N·m. 

Minor injury due to electric shock may occasionally 
occur. Do not touch the terminals while power is 
being supplied. Always close the terminal cover after 
wiring. 

Minor electric shock, fire, or Product failure may 
occasionally occur. Do not allow any pieces of metal 
or conductors or any clippings or cuttings resulting 
from installation work to enter the Product. 

Mounting

Take adequate measures to ensure proper heat dissipation to 
increase the long-term reliability of the Product. 

Be sure to allow convection in the atmosphere around devices when 
mounting. Do not use in locations where the ambient temperature 
exceeds the range of the derating curve. (except 600 W)

The S8JX-

@

60024

@

 is designed to radiate heat by means of 

forced air-flow. Do not cover the air holes (provided at fan mounted 
side and the opposite side) to have enough air-cooling.

The screws must not protrude more than 8 mm inside the Power 
Supply when screw holes provided on the chassis are used. (300 
W, 600 W) 
Mounting screw tightening torque (recommended value) : 0.54 N

·

m.

Rear mounting is possible using provided mounting bracket.

When cutting out holes for mounting, make sure that cuttings do 
not enter the interior of the Products.

Improper mounting will interfere with heat dissipation and may 
occasionally result in deterioration or damage of internal parts. Use 
the standard mounting method only. 

The internal parts may occasionally deteriorate and be broken due 
to adverse heat radiation. Do not loosen the screw on the side face 
of the main body.

When mounting two or more Power Supplies side-by-side, allow at 
least 20 mm spacing between them. 

Provide a space of at least 20 mm back and forth when mounting 
300-W and 600-W models as well.

Use the metal plate as the mounting panel. 

*1.

Convection of air

*2.

20 mm max.

*3.

Use a metal plate as the mounting surface. 

 CAUTION

Precautions for Safe Use

15-/35-/50-/100-/150-W Models

300-W Model

600-W Model

Standard Mo

u

nting 

(Horizontal Mo

u

nting) 

*

*

*

*

Standard Mo

u

nting 

(Bottom-mo

u

nting)  

*

*

*

*

*

*

*

Standard Mo

u

nting 

(Front-mo

u

nting and DI

N

 Rail-mo

u

nting) 

*

1

*

1

*

1

*

3

*

2

*

2

Standard Mo

u

nting

(Bottom-mo

u

nting) 

Standard Mo

u

nting

(Front-mo

u

nting and DI

N

 Rail-mo

u

nting)

*

1

*

1

*

3

Summary of Contents for S8JX -

Page 1: ...lass A Note Refer to Safety Precautions on page 17 Model Number Structure Model Number Legend Note Not all combinations are possible Refer to List of Models in Ordering Information on page 2 1 Power Ratings 015 15 W 035 35 W 050 50 W 100 100 W 150 150 W 2 Output Voltage 05 5 V 12 12 V 15 15 V 24 24 V 3 Configuration 15 35 50 100 150 W model None Open frame C Covered 4 Configuration mounting None F...

Page 2: ...JX G03524D 50 W 5 V 10 A S8JX G05005D 12 V 4 2 A S8JX G05012D 24 V 2 1 A S8JX G05024D 100 W 5 V 20 A S8JX G10005D 12 V 8 5 A S8JX G10012D 24 V 4 5 A S8JX G10024D 150 W 24 V 6 5 A S8JX G15024D Covered Power Supplies Front mounting 1 15 W 5 V 3 A S8JX G01505C 12 V 1 3 A S8JX G01512C 15 V 1 A S8JX G01515C 24 V 0 65 A S8JX G01524C 35 W 5 V 7 A S8JX G03505C 12 V 3 A S8JX G03512C 15 V 2 4 A S8JX G03515C...

Page 3: ...ure variation influence 0 05 C max at rated input and output Startup time 500 ms max up to 90 of output voltage at rated input and output Hold time 3 20 ms min Additional functions Overload protection 6 105 to 160 of rated load current voltage drop intermittent automatic reset Overvoltage protection 7 Yes Overheat protection No Parallel operation No Series operation Yes For up to two Power Supplie...

Page 4: ...ence 0 05 C max at rated input and output Startup time 500 ms max up to 90 of output voltage at rated input and output Hold time 3 20 ms min Additional functions Overload protection 6 105 to 160 of rated load current voltage drop intermittent automatic reset Overvoltage protection 7 Yes Overheat protection No Parallel operation No Series operation Yes For up to two Power Supplies external diodes r...

Page 5: ...ted input voltage Temperature variation influence 0 05 C max Startup time 650 ms max 500 ms max Hold time 3 20 ms min Additional functions Overload protection 6 105 of rated load current voltage drop intermittent automatic reset 105 of rated load current Inverted L voltage drop the circuit will be shut OFF when the overload exceeds 5 s 9 Overvoltage protection 7 Yes Yes 9 Overheat protection No Ye...

Page 6: ...A AC L INPUT AC N Rectifier Smoothing circuit Rectifier Smoothing circuit Overvoltage detection circuit S8JX G035 35 W Voltage detection Photocoupler Drive control Circuit Overcurrent detection circuit V V DC OUTPUT Noise filter Inrush current protection Fuse 6 3 A AC L INPUT AC N Rectifier Smoothing circuit Rectifier Smoothing circuit Overvoltage detection circuit S8JX G050 50 W DC OUTPUT INPUT V...

Page 7: ...thing circuit Parallel operation selector 100 200V Selectable S8JX G30024 300 W Note Short circuit the input voltage selector terminals if the input is 100 to 120 VAC Keep the terminals open if the input is 200 to 240 VAC Fan INPUT DC OUTPUT Voltage detection V V Noise filter Inrush current protection Fuse 10 A AC L AC N Photocoupler Drive control Circuit Overcurrent detection circuit Overheat det...

Page 8: ...al Connect the ground line to these terminals 2 4 Input Voltage Selector Terminals Short circuit the terminals if the input is 100 to 120 VAC and open the terminals if the input is 200 to 230 VAC 5 Output Indicator DC ON Green Lights while a Direct Current DC output is ON 6 Output Voltage Adjuster V ADJ It is possible to increase or decrease the output voltage 7 Protection ON Alarm Indicator DC ON...

Page 9: ...he Power Supply in areas outside the derating curve i e the area shown by shading A in the above graph 2 If there is a derating problem use forced air cooling 15 35 50 100 150 W Models 300 600 W Models 20 10 0 10 20 30 40 50 60 70 80 120 100 80 60 40 20 0 Load rate 20 10 0 10 20 30 40 50 60 70 80 120 100 80 60 40 20 0 Load rate Ambient Temperature C Ambient Temperature C A A Solid line Dotted line...

Page 10: ...rtical Side mounting Horizontal Side mounting Front mounting 20mm min 20mm min 20mm min 20mm min Bottom mounting Side mounting DIN Rail mounting Note 1 Improper mounting will interfere with heat dissipation and may occasionally result in deterioration or damage of internal parts Use the standard mounting method only 2 When mounting the Power Supply mounting it to a metal plate is recommended 3 Ins...

Page 11: ...o overvoltage Reset the input power by turning it OFF for at least seven minutes and then turning it back ON again Consider the possibility of an overvoltage and design the system so that the load will not be subjected to an excessive voltage even if the feedback circuit in the Power Supply fails When an excessive voltage that is approximately 130 of the rated voltage or more is output the output ...

Page 12: ... screw mounting Side Mounting Bottom Mounting Two M3 75 0 5 92 0 5 Two M3 92 0 5 3 5 dia 3 5 dia 3 5 Two M3 Depth 4 mm max 8 2 9 5 Five M3 5 10 max 100 1 92 1 75 0 5 3 5 36 1 40 1 4 5 4 5 92 0 5 92 0 5 65 0 5 20 26 5 20 5 max 8 Label Cover S8JX G050 50 W S8JX G050 C 50 W Panel mounting holes dimensions Surface screw mounting Side Mounting Bottom Mounting Two M3 75 0 5 141 0 5 Two M3 141 0 5 S8JX G...

Page 13: ... Mounting Bottom Mounting 50 0 5 136 0 5 Four 4 5 dia 90 0 5 136 0 5 Four 4 5 dia S8JX G30024C 300 W 10 8 6 159 8 1 24 4 0 5 11 124 0 5 50 0 5 20 9 14 8 100 0 5 42 137 0 5 8 6 10 150 1 92 1 Nine M4 terminal screws Eight M4 holes depth 8 max on both sides Four M4 holes depth 8 max Panel mounting holes dimensions Surface screw mounting Side Mounting Bottom Mounting 50 0 5 124 0 5 Four 4 5 dia 100 0 ...

Page 14: ... Dimensions Mounting dimensions 11 9 1 5 60 11 20 5 31 5 20 5 15 4 7 4 6 4 6 15 0 2 74 Two 3 5 dia t 1 0 Material Stainless steel Two M3 20 60 b b a a Power Supply Mounting bracket Note Mounting screws are not provided 48 t 1 6 15 30 7 5 7 5 160 145 0 5 R2 5 10 dia 32 36 4 0 2 92 Four 5dia Note Mounting Brackets are provided in a set one for the right side and one for the left side 145 0 5 80 0 5 ...

Page 15: ...ax 7 Sliding 16 6 max S8JX G050 D 50 W S8JX G050 CD 50 W 8 2 9 5 Five M3 5 36 1 40 1 6 max 44 1 10 max 100 1 92 1 47 14 5 max 108 6 5 max 7 Sliding 16 6 max Label Cover S8JX G100 D 100 W S8JX G100 CD 100 W S8JX G15024D 150 W S8JX G15024CD 150 W 8 2 9 5 Five M3 5 48 1 50 1 10 max 150 1 5 max 92 1 47 7 Sliding 16 6 max 158 6 6 max 50 1 14 5 max 100 150 W 150 W 100 W Label Cover ...

Page 16: ...nit 92 1 4 max 4 4 Sliding 10 max 4 6 max 110 1 4 6 max 10 8 6 Nine M4 terminal screws 10 2 167 1 1 20 max 46 6 181 3 17 7 S8JX G30024CD 300 W Mounting Rail Material Aluminum 4 5 15 25 25 10 10 1 000 500 25 25 15 5 35 0 3 7 3 0 15 27 0 15 1 Value in parentheses are for PFP 50N Model PFP 100N PFP 50N Mounting Rail Material Aluminum 4 5 15 25 25 10 10 1 000 25 25 15 1 1 5 29 2 24 27 35 0 3 16 Model ...

Page 17: ...ir holes provided at fan mounted side and the opposite side to have enough air cooling The screws must not protrude more than 8 mm inside the Power Supply when screw holes provided on the chassis are used 300 W 600 W Mounting screw tightening torque recommended value 0 54 N m Rear mounting is possible using provided mounting bracket When cutting out holes for mounting make sure that cuttings do no...

Page 18: ...After completing output voltage adjustment be sure that the output capacity or output current does not exceed the rated output capacity or rated output current DIN Rail mounting To mount the Power Supply to a DIN Rail pull down the rail stopper until you hear it clicks open hook portion A of the Power Supply onto the DIN Rail press the Power Supply in direction B and then push up the rail stopper ...

Page 19: ...voltage can be switched between 100 and 200 V by shorting or opening the input voltage selection terminals Set the required voltage as shown below The voltage is factory set to 200 V Note A 300 W model is shown above Fan Replacement The service life of the fan is approximately 50 000 hours at 25 C The service life varies however depending on the ambient temperature or other surrounding environment...

Page 20: ...models 0 20 p p 0 20 p p 0 30 p p 0 50 p p 15 V models 0 15 p p 0 15 p p 24 V models 0 10 p p 0 15 p p 0 15 p p 0 25 p p 0 45 p p 0 75 p p 0 60 p p f 100 MHz measuring 5 V models 0 50 p p 0 55 p p 0 75 p p 1 50 p p 12 V models 0 30 p p 0 35 p p 0 35 p p 0 70 p p 15 V models 0 20 p p 0 30 p p 24 V models 0 20 p p 0 20 p p 0 20 p p 0 40 p p 0 60 p p 1 10 p p 0 60 p p Start up time See note 1 at 100 ...

Page 21: ...21 MEMO ...

Page 22: ...MEMO 22 ...

Page 23: ...combination of products in the customer s application or use of the products Take all necessary steps to determine the suitability of the product for the systems machines and equipment with which it will be used Know and observe all prohibitions of use applicable to this product NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS...

Page 24: ...173 5302 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 OMRON ASIA PACIFIC PTE LTD No 438A Alexandra Road 05 05 08 Lobby 2 Alexandra Technopark Singapore 119967 Tel 65 6835 3011 Fax 65 6835 2711 OMRON CHINA CO LTD Room 2211 Bank of China Tower 200 Yin Cheng Zhong Road PuDong New Area Shanghai 200120 China Tel 86 21 5037 2222 Fax 86 21 5037 2200 OMRON Industrial Automation Global www ia omron com Cont...