background image

New Product

1

S8JX-P

S8JX-G

Common Precautions

Switch Mode Power Supply

S

8

JX 

(15/35/50/100/150/300/600-W Models)

Easy-to-use, Widely range from 15 W to 600 W (Output Voltage: 5 V to 4

8

 V)

• Easy Mounting: 

Front-mounted type, DIN rail-mounted type are 
available.
Screw-mount at the top. (except 300-/600-W models)

• Safety standards:

UL 508/60950-1
cUL CSA C22.2 No. 107.1
cUR CSA C22.2 No. 60950-1
EN 50178 (= VDE 0160) Over voltage 
category III
EN 60950-1 (= VDE 0805 Teil 1) 

• EMC: Conforms to EN 61204-3.

(EMI:EN55011 ClassA)

• Input conditions: 

The input voltage range of 15-W, 35-W, 
50-W, 100-W, and 150-W models has 
been increased to 80 to 370 VDC (EC 
Directives and safety standards do not 
apply.). 

S

8

JX-P Series with EMI ClassB and Power Factor Correction is newly 

added to S

8

JX Series.

(Applicable to all capacities from 50 W to 600 W) 
• Limits for harmonic current emissions (conforms to 

EN61000-3-2)

• Conforms to EMI EN55011 Class B
• Applicable to input free voltage: 100 to 240 VAC
• Extended DC input voltage range: 80 to 370 VDC

*

 DC input is not subject to EC directives and safety standards.

• Easy mounting: Front-mounting bracket type and 

DIN-Rail mounting type are included 
as standard with the product. 
Screw-mount at the top. 
(except 300-/600-W models)

• Safety standards

- UL508/60950-1, cUL CSA C22.2 No.107.1,

cUR CSA C22.2 No.60950-1

- EN50178 (=VDE0160) Over voltage category III

EN60950-1 (=VDE0805 Teil1)

<Applicable only for 300 W and 600 W>
• High capacity application-covered functions are 

included as standard with the product. 

• Alarm detection function, Remote control function, 

Remote sensing function

S

8

JX-G Series

S

8

JX-P Series

For the most recent information on models that have been certified for 
safety standards, refer to your OMRON website.

For the most recent information on models that have been certified for 
safety standards, refer to your OMRON website.

Refer to 

Safety Precautions

 on 

page 55

.

Summary of Contents for S8JX-G Series

Page 1: ...nt emissions conforms to EN61000 3 2 Conforms to EMI EN55011 Class B Applicable to input free voltage 100 to 240 VAC Extended DC input voltage range 80 to 370 VDC DC input is not subject to EC directi...

Page 2: ...nfiguration 15 35 50 100 150 W model None Open type C Covered 4 Configuration mounting None Front mounting D DIN Rail mounting 1 Power Ratings 300 300 W 600 600 W 2 Output Voltage 05 5V 12 12 V 24 24...

Page 3: ...0 W 5 V 20 A S8JX G10005CD 12 V 8 5 A S8JX G10012CD 24 V 4 5 A S8JX G10024CD 48 V 2 1 A S8JX G10048CD 150 W 5 V 30 A S8JX G15005CD 12 V 13 A S8JX G15012CD 24 V 6 5 A S8JX G15024CD 48 V 3 3 A S8JX G150...

Page 4: ...X G01524C 48 V 0 35 A S8JX G01548C 35 W 5 V 7 A S8JX G03505C 12 V 3 A S8JX G03512C 15 V 2 4 A S8JX G03515C 24 V 1 5 A S8JX G03524C 48 V 0 75 A S8JX G03548C 50 W 5 V 10 A S8JX G05005C 12 V 4 2 A S8JX G...

Page 5: ...240 VAC DC power cannot be input 15 W 5 V 3 A No Provided S8JX G01505 12 V 1 3 A S8JX G01512 15 V 1 A S8JX G01515 24 V 0 65 A S8JX G01524 48 V 0 35 A S8JX G01548 35 W 5 V 7 A S8JX G03505 12 V 3 A S8J...

Page 6: ...tion influence 0 05 C max at rated input and output Startup time 500 ms max up to 90 of output voltage at rated input and output Hold time 3 20 ms min Additional functions Overload protection 6 105 to...

Page 7: ...age Temperature variation influence 0 05 C max at rated input and output Startup time 500 ms max up to 90 of output voltage at rated input and output Hold time 3 20 ms min Additional functions Overloa...

Page 8: ...fluence 0 8 max 0 to 100 load rated input voltage Temperature variation influence 0 05 C max at rated input and output Startup time 500 ms max up to 90 of output voltage at rated input and output Hold...

Page 9: ...0 Parallel operation Yes up to 5 units Series operation Yes For up to two Power Supplies external diodes required Protective circuit operation indicator Yes color red 5V 12V No 24V 48V Yes color red O...

Page 10: ...o Ripple Noise Voltage on page 57 7 For details refer to Overload Protection on page 20 8 To reset the protection turn OFF the input power for three minutes or longer and then turn it back ON 9 The we...

Page 11: ...ier smoothing circuit Noise filter Inrush current protection Fuse 2 0 A AC L INPUT AC N Rectifier Smoothing circuit S8JX G01548 15 W Voltage detection Photocoupler Drive control Circuit Overcurrent de...

Page 12: ...W Voltage detection circuit Photocoupler Overvoltage detection circuit Drive control circuit Overcurrent detection circuit V V DC OUTPUT Rectifier smoothing circuit Noise filter Inrush current protect...

Page 13: ...Photocoupler Drive control Circuit Overcurrent detection circuit Smoothing circuit Overvoltage detection circuit Rectifier Smoothing circuit S8JX G15012 150 W S8JX G15024 150 W S8JX G15048 150 W INPUT...

Page 14: ...ection circuit Overheat detection circuit Overvoltage detection circuit Rectifier Smoothing circuit Rectifier Smoothing circuit Parallel operation selector 100 200V Selectable Rectifier Smoothing circ...

Page 15: ...5C is shown above V V V V AC L AC N Bottom Note The S8JX G30005C is shown above 1 The fuse is located on the L side It is NOT user replaceable 2 This is the protective earth terminal specified in the...

Page 16: ...ove 1 The fuse is located on the L side It is NOT user replaceable 2 This is the protective earth terminal specified in the safety standards Always ground this terminal No Name Function 1 DC Output Te...

Page 17: ...ve i e the area shown by shading in the above graph 2 If there is a derating problem use forced air cooling Single Unit Operation Parallel Operation Note 1 Internal parts may occasionally deteriorate...

Page 18: ...DIN Rail mounting Bottom mounting Vertical Side mounting Horizontal Side mounting Front mounting Bottom mounting 20mm min 20mm min 20mm min 20mm min Side mounting DIN Rail mounting Note 1 Improper mou...

Page 19: ...oper mounting will interfere with heat dissipation and may occasionally result in deterioration or damage of internal parts Use the standard mounting method only 2 When mounting the Power Supply mount...

Page 20: ...d if a short circuited or overcurrent state continues during operation 3 Internal parts may possibly deteriorate or be damaged if the Power Supply is used for applications with frequent inrush current...

Page 21: ...00 W 24V 48V models Reset the input power by turning it OFF for at least three minute and then turning it back ON again Reference value Note Do not turn ON the power again until the cause of the overv...

Page 22: ...rew mounting Side Mounting Bottom Mounting Two M3 75 0 5 92 0 5 Two M3 92 0 5 3 5 dia 3 5 dia 3 5 Two M3 Depth 4 mm max 8 2 9 5 Five M3 5 10 max 100 1 92 1 75 0 5 3 5 36 1 40 1 4 5 4 5 92 0 5 92 0 5 6...

Page 23: ...imensions Surface screw mounting Side Mounting Bottom Mounting 169 0 5 68 0 5 Two M3 169 0 5 Two M3 S8JX G15005 150 W S8JX G15005C 150 W 92 1 36 33 5 3 5 3 5 5max 10max 68 0 5 8 60 1 9 5 8 2 169 0 5 1...

Page 24: ...w mounting Side Mounting Bottom Mounting 50 0 5 136 0 5 Four 4 5 dia 90 0 5 136 0 5 Four 4 5 dia S8JX G30005C 300 W S8JX G30012C 300 W 92 1 4 max 110 1 10 8 6 Nine M4 terminal screws 19 136 0 5 90 0 5...

Page 25: ...nting holes dimensions Surface screw mounting Side Mounting Bottom Mounting 50 0 5 124 0 5 Four 4 5 dia 100 0 5 137 0 5 Four 4 5 dia 10 8 6 159 8 1 24 4 0 5 11 124 0 5 50 0 5 20 9 14 8 100 0 5 42 137...

Page 26: ...aching the Mounting Brackets Dimensions Mounting dimensions 11 9 1 5 60 11 20 5 31 5 20 5 15 4 7 4 6 4 6 15 0 2 74 Two 3 5 dia t 1 0 Material Stainless steel Two M3 20 60 b b a a Power Supply Mounting...

Page 27: ...W 24 V models Front mounting Mounting bracket D For S8JX G series 100 W 5 V 12 V 150 W models S82Y JX15F 25 W models Underside mounting Mounting bracket E For S8JX G series 30 W models S82Y JX03B 300...

Page 28: ...0 0 5 4 5 25 45 45 6 54 5 dia Thickness 1 6 B B A A Mounting Bracket D S82Y JX15F Screws used A Accessories 2 locations Be sure to use the accessory screws Mounting screw tightening torque recommended...

Page 29: ...the body should be placed 21 6 mm in front of the mounting side Method of Mounting Front Thickness 3 2 169 150 0 1 9 45 100 0 1 170 Eight M4 A A A B B B Mounting Bracket H S82Y JX60B Screws used A Acc...

Page 30: ...7 Sliding 16 6 max S8JX G050 D 50 W S8JX G050 CD 50 W 8 2 9 5 Five M3 5 36 1 40 1 6 max 44 1 10 max 100 1 92 1 47 14 5 max 108 6 5 max 7 Sliding 16 6 max Label Cover S8JX G100 D 100 W S8JX G100 CD 10...

Page 31: ...switch 12 max 14 5 max 5 max 7 Sliding 16 6 max 178 1 186 6 2 M4 Label 3 M3 5 Cover 13 9 5 8 2 10 S8JX G15005D 150 W S8JX G15005CD 150 W 9 5 8 2 10 max 178 1 5 M3 5 Cover 6 max 60 1 14 5 max 92 1 47 5...

Page 32: ...terminal screws 6 5 max S8JX G30005CD 300W S8JX G30012CD 300W Note Use a metal DIN Rail when mounting a 300 W model to a DIN Rail 92 1 4 max 4 4 Sliding 10 max 6 5 max 110 1 6 5 max 10 8 6 Nine M4 te...

Page 33: ...e Power Supply and applicable location S82Y JX C4P S8JX G 300W 24 V or 48 V output S8JX G 600W 24 V or 48 V output S82Y JX C5P S8JX G 300W input S8JX G 600W input S82Y JTC1 S8JX G 15W S8JX G 30W S8JX...

Page 34: ...MEMO 34...

Page 35: ...50 W model None Open type C Covered 4 Configuration mounting None Front mounting D DIN Rail mounting 1 Power Ratings 300 300 W 600 600 W 2 Output Voltage 05 5V 12 12 V 24 24 V 48 48 V 3 Configuration...

Page 36: ...S8JX P10024CD 48 V 2 1 A S8JX P10048CD 150 W 05 V 30 A S8JX P15005CD 12 V 13 A S8JX P15012CD 24 V 6 5 A S8JX P15024CD 48 V 3 3 A S8JX P15048CD 300 W 5 V 60 A Yes S8JX P30005CD 12 V 27 A S8JX P30012CD...

Page 37: ...V 27 A S8JX P30012C 24 V 14 A peak current 16 5 A 200 VAC S8JX P30024C 48 V 7 A S8JX P30048C 600 W 5 V 120 A S8JX P60005C 12 V 53 A S8JX P60012C 24 V 27 A peak current 31 A 200 VAC S8JX P60024C 48 V...

Page 38: ...nput variation influence 0 4 max with AC input voltage Load variation influence 0 8 max 0 to 100 load rated input voltage Temperature variation influence 0 05 C max at rated input and output Startup t...

Page 39: ...ngineering Data on page 44 with no icing or condensation Storage temperature 25 to 75 C with no icing or condensation Ambient operating humidity 25 to 85 Storage humidity 25 to 90 Dielectric strength...

Page 40: ...ual output voltage from the Power Supply and be sure that load is not damaged 6 For details refer to Overload Protection on page 46 7 To reset the protection turn OFF the input power for three minutes...

Page 41: ...5 A AC L INPUT AC N Rectifier Smoothing circuit Rectifier Smoothing circuit High frequency current regulation S8JX P050 50 W Voltage detection Photocoupler Overvoltage detection circuit Drive control...

Page 42: ...vercurrent detection circuit Rectifier Smoothing circuit Voltage detection Overvoltage detection circuit S8JX P300 300 W INPUT AC L AC N DC OUTPUT V V V V S S CB CBG RC RC ALM ALMC ALME Fuse 20 A Nois...

Page 43: ...above 5 7 6 4 2 1 3 3 5 4 6 7 1 2 1 The fuse is located on the L side Ensure that the L side is set to 2 This is a PE Protective Earth terminal defined in safety standards and must be grounded 3 Sign...

Page 44: ...ottom mounting Horizontal side mounting Note 1 Internal parts may occasionally deteriorate or be damaged Do not use the Power Supply in areas outside the derating curve i e the area shown by shading i...

Page 45: ...s recommended 3 Install the Power Supply so that the air flow circulates around the Power Supply as the Power Supply is designed to radiate heat by means of natural air flow Note 1 Improper mounting w...

Page 46: ...nector provided as standard and prepare a harness separately Alarm detection function When output voltage drops due to overcurrent protection overvoltage protection or overheat protection in operation...

Page 47: ...following conditions should be satisfied for the peak current value Note 1 Do not hold peak load current over 10 seconds In addition you should not use duty cycle under conditions beyond above figure...

Page 48: ...2 1 78 5 0 5 42 1 5 118 0 5 5 120 0 5 86 0 5 15 36 22 Label 5 max 7 3 5 for mounting 3 5 dia for mounting 3 5 dia for mounting 8 2 9 5 Five M3 5 Label 42 1 11 5 max 159 1 5 max 5 148 0 5 Two M3 Depth...

Page 49: ...mounting 8 2 9 5 10 13 Three M3 5 Two M4 Label 42 1 13 5 max 159 1 5 max 5 148 0 5 Two M3 Depth 4 mm max 98 0 5 15 3 5 for mounting 36 22 5 150 0 5 92 1 78 5 0 5 7 Cover 3 5 for mounting Panel mountin...

Page 50: ...0 5 70 1 110 8 1 77 6 1 13 5 5 8 5 10 16 13 26 4 5 Three M4 214 3 239 8 max Four M5 120 0 5 110 0 5 35 0 5 46 0 5 71 1 165 1 92 1 14 24 1 8 5 10 Three M4 20 Four M4 Depth 6 mm max Four M4 Depth 6 mm...

Page 51: ...crew mounting Front Mounting 113 5 0 5 93 0 5 Three 4 5 dia S8JX P600 C 600 W 16 13 Four M5 10 8 5 Three M4 22 5 max Four M4 Depth 6 mm max Four M4 Depth 6 mm max 25 21 40 5 max 110 1 26 92 1 50 0 5 1...

Page 52: ...5 max 5 max 92 1 7 Sliding 16 6 max 167 6 11 5 max 6 max 43 4 1 Label 8 2 9 5 Five M3 5 Cover 42 1 47 S8JX P100 D 100 W S8JX P100 CD 100 W S8JX P15012D 150 W S8JX P15012CD 150 W S8JX P15024D 150 W S8...

Page 53: ...2 max 214 3 239 8 max 9 1 5 5 46 S8JX P300 CD 300 W Note Use a metal DIN Rail when mounting a 300 W model to a DIN Rail 6 6 13 16 8 5 Four M5 Three M4 Sliding 12 max 214 3 239 8 max 5 5 109 1 26 110 8...

Page 54: ...et parts b and secure the Power Supply with two mounting screws Terminal Cover model Applicable Power Supply and applicable location S82Y JTC1 S8JX P50W S8JX P100W S8JX P150W 12 V 24 V or 48 V output...

Page 55: ...r cooling The screws must not protrude beyond the following values inside the Power Supply when screw holes provided on the chassis are used 15 W 35 W 50 W 100 W or 150 W 4 mm 300 W or 600 W of S8JX P...

Page 56: ...lar install the Power Supply as far away as possible from contactors or other devices that are a vibration source Install the Power Supply well away from any sources of strong high frequency noise and...

Page 57: ...nerated inside the Power Supply If this occurs the Power Supply may possibly deteriorate or be damaged Always connect a diode as shown in the figure Select a diode having the following ratings 2 Altho...

Page 58: ...on may operate if a large amount of surge voltage such as a lightening surge occurs while turning ON the Power Supply In case there is no output voltage please check the following points before contac...

Page 59: ...the fan as shown in the following illustration Please contact your OMRON sales representative regarding fan replacement Fans will be replaced at cost In addition a replacement fan unit Model S82Y JXP...

Page 60: ...ombination of products in the customer s application or use of the products Take all necessary steps to determine the suitability of the product for the systems machines and equipment with which it wi...

Page 61: ...IL 60173 5302 U S A Tel 1 847 843 7900 Fax 1 847 843 7787 Regional Headquarters OMRON EUROPE B V Wegalaan 67 69 2132 JD Hoofddorp The Netherlands Tel 31 2356 81 300 Fax 31 2356 81 388 Contact www ia o...