Promi-SD User Manual – Appendix D. Connection to Omron PLC
D-3
Copyright © 2006 Sena Technologies, Inc. All rights reserved.
Select MODE3 by selecting the radio button
Set the Baud Rate, Parity and StopBit
(H/W Flow Control is not applicable for the Promi-SD205OA)
Set a Device Name (16 characters max)
Tick the Authentication tickbox and set a Password (caption sensible)
Note: Password is only saved if the tickbox Authentication is ticked
Tick the Encryption tickbox (if preferred)
Click the Apply button to store all the settings in the Promi-SD205 OA
Close PromiWin
Power off the Promi-SD205 OA and power it on again
Select My Bluetooth places in Windows Explorer or in the taskbar