Promi-SD 205-OA User Manual – 2. Configurations
18
Copyright © 2006 Sena Technologies, Inc. All rights reserved.
For Promi-SD205 OA pin 4 and pin 5 are connected in the hardware to disable hardware flowcontrol. Thus H/W Flow
Control option will not work in this case. When the dip switch value isn’t ATcommand mode, the RS-232 menu is
disabled.
Click [Apply] button to reflect the given options to Promi-SD actually.
Connect(out) icon will show the following window to search and connect other Bluetooth devices.
Click [Search] button to search nearby Bluetooth devices. The maximum number of devices to be searched can be
controlled. Select one of the devices searched and click [Connect] button. The selected Bluetooth device must be in
Page scan mode. Click [Disconnect] button to cancel the connection normally.
After the connectionis established, you can test sensitivity through the START button.
The sensitivity test shows LInkQuality and RSSI values. If the LinkQuality approaches to 255 and RSSI approaches to 0, the
sensitivity is good. In general, when the distance is 10 meters, the sensitivity is the best. You can push the STOP button in
order to terminate the sensitivity test. The sensitivity test will continue until the STOP button is puished. If you close the the
PromiWin without pushing the STOP button, you must restart SD to terminate the test.
Connection(in) icon will show the following window to make Promi-SD wait to a connection from the other Bluetooth
device. The waiting time in seconds can be controlled. With 0 input for this waiting time, Promi-SD keeps waiting for