Function
Simple
Shutdown
Software
Required options
SC07
BUC26
SNMP/Web
card SC20G
Compatible OS
Linux
Auto shutdown
(*1)
UPS monitoring (operating status)
UPS monitoring (data)
Pop-up notification
(*2)
End when OS is inactive (*3)
Auto file sabe (*3)
Schedule operation
UPS setting change
Event log save
Data log save
Redundant power supply support
Remote UPS management
Mail send
SNMP management
SYSLOG support
Standard Option Limited
UPS service
driver
OS standard
UPS service
PowerAct Pro 4.x
SNMP/Web
card
Software title
General applications
(Simple functions, standalone)
Network management
applications
(Advanced functions,
network support)
SNMP management
applications
(Advanced functions,
network support)
Software
function
Windows 7
Windows Vista
Windows Server2008 (including R2)
Windows Server 2003 x64 Edition
Windows XP x64 Edition
Windows Server 2003
Windows XP/2000
Windows NT4.0
Mac OS X v10.6/v10.5
Mac OS X Server v10.6/v10.5
External command execution
Coordinated shutdown (shutdown
of multiple units)
Output receptacle control
Telnet connection
(*4)
(*4)
(*5)
• UPS monitoring software function list
[Explanation of software functions]
1
Auto shutdown
The computer can be shut down automatically when a problem occurs with the power supply.
2
UPS monitoring (operating
status)
The operating status of the UPS can be monitored (in Commercial Power Mode/Battery Mode).
3
UPS monitoring (data)
Monitoring can be performed for input voltage value, connection capacity, battery capacity, etc.
4
Pop-up noti
fi
cation
When a problem such as a power failure occurs, a pop-up window that shows the details of the problem can be displayed.
5
S h u t d o w n w h e n O S i s
inactive
Shutdown can be performed when the computer is in an inactive state. The operating status is retained at shutdown in inactive
state, so operation details are not lost.
6
Auto
fi
le save
Files such as open Word and Excel documents are automatically saved at shutdown.
7
Schedule operation
Schedule settings can be made for UPS stop/start.
8
UPS setting change
UPS settings (beep ON/OFF, etc.) can be changed. (Items that can be set vary according to the UPS.)
9
E x t e r n a l c o m m a n d
execution
By executing commands at shutdown, items such as application programs can be launched.
10 Event log save
Information of events that occur on the UPS (power supply problems, setting changes, occurrences of failure, etc.) are saved
as a log.
11 Data log save
Data of input/output voltage value, connection capacity, etc. is periodically saved as a log (the save frequency can be set).
12 Coordinated shutdown
When a problem occurs with the power supply, multiple computers connected to the UPS can coordinate to perform auto
shutdown.
13 Output receptacle control
The UPS output receptacles can be individually set to ON/OFF.
14 Redundant power supply
support
Two or more UPS can be connected to computers equipped with redundant power supply. Shutdown is not performed when a
power supply proble affects only one of the units. Shutdown is performed only when a power supply problem occurs with both
UPS, so the system's operating rate is improved.
15 Remote UPS management The UPS can be managed remotely from a computer on the network.
16 Mail send
When a problem such as a power failure occurs, a notification email describing the problem can be sent to the system
administrator.
17 SNMP management
UPS management information can be sent to the SNMP manager.
18 Telnet connection
Settings such as shutdown parameters can be made via the Telnet connection.
19 SYSLOG support
UPS management information can be recorded in SYSLOG.
*1) The UPS automatically stops only when the battery is depleted. (Battery Mode continues until the battery is depleted.)
*2) Only the battery capacity can be monitored.
*3) This function is available only for Windows, not for Linux.
*4) Compatible with PowerAct Pro Ver 4.1 or later.
*5) Not compatible with Windows 2000.