background image

OS32C

Safety sensors

10

Miscellaneous

Connection

Basic connection with single OS32C unit 
Category 3, performance level d (ISO13849-1)

Appearance

Description

Remarks

Order code

Scan window

Spare for replacement

OS32C-WIN-KT

Sensor block without I/O block
Max. operating range: 3 m

Spare for replacement

OS32C-SN

Sensor block without I/O block
Max. operating range: 4 m

OS32C-SN-4M

Sensor block without I/O block for EtherNet/IP
Max. operating range: 3 m

Spare replacement for EtherNet/IP

OS32C-SN-DM

Sensor block without I/O block for EtherNet/IP
Max. operating range: 4 m

OS32C-SN-DM-4M

I/O block

With cable access 
from the back

Spare for replacement

OS32C-CBBP

With cable access 
from the left side

Spare for replacement

OS32C-CBSP1

Window cleaning kit, anti-static cleaner

Accessory

WIN-CLN-KT

24 VDC (White)

0 VDC (Brown)
Standby input (Violet)
Zone select 1 (Orange/White)

Zone select 2 (Orange/Black)
Zone select 3 (Gray)
Zone select 4 (Pink)
Zone select 5 (White/Black)

Start (Black)
Auxiliary output (Blue)

Warning output (Red/Black)

EDM (Brown/White)

Safety output B (Yellow)

Safety output A (Red)

Zone select 6 (Tan)
Zone select 7 (Orange)
Zone select 8 (Blue/White)

Functional earth (Green)

ED1

ED2

*1

*1

*2

S2

S3

S2

S1

*3

*4

*4

S2

*4

S2

*4

S2

*4
*4
*4
*4

S2
S2
S2

0V

E1

+24V

PE

ED1

ED2

M1

ED1

ED2

S1 : Start input
S2 : Zone select switch
S3 : Standby switch
ED1, ED2: Forced guided relay
M1 : 3-Phase motor
E1 : 24 VDC Power

OS32C configuration
– External Device Monitoring enabled
– Start/restart interlock

*1.

External devices (ED1, ED2) are forced guide relays. (G7Z, G7SA, G7S, etc)

*2.

If the External Device Monitoring is not used, connect brown/white wires to 0 V, and then turn OFF the 
External Device Monitoring with the configuration software.

*3.

Use NC-contact for a start input.

*4.

For zone select switch setting, refer to OS32C Series user's manual.

Note:

This wiring example is for category 3.

OS32C_tecPart_rev04.fm  Seite 10  Donnerstag, 2. Oktober 2014  9:36 09

OS32C

Safety sensors

11

Dimensions

OS32C with back location cable entry - OS32C-BP/OS32C-BP-DM

OS32C with side location cable entry - OS32C-SP1/OS32C-SP1-DM

158.3 [6.24]

90.4 [3.56]

Ethernet connector

with M12 cap plug

Window

Dust 

detection

Ethernet cable not shown

Ethernet

cable

I/O cable

I/O cable

I/O block

Sensor head

140.4 [5.53]

100.0 [3.94]

32.8 [1.29]

50.9 [2.01]

104.3 [4.11]

133.0 [5.24]

M5 x 0.8,

DEPTH 9.0 [0.35]

MAX (x4)

41.4 [1.63]

MTG holes

6.0 [0.24]

57.0 [2.25]

50.0 [1.97]

27.7 [1.09]

104.5 [4.12]

67.0 [2.64]

Scan plane

2.0, 3.0, 10.0, 20.0, or 30.0 Meters

30.0 [1.18] dia. OD 

102.9 [4.05]

I/O cable assy

270 (10.63)

121.0 [4.77]

MTG holes

142.7 [5.62]

88.1 [3.47]

71.5 [2.82]

71.3 [2.81]

(min)

Back view

Bottom view

Side view

Front view

Top view

Ethernet

cable

Window

Dust 

detection

I/O block

Sensor head

I/O cable

I/O cable

30.0 [1.18] dia. OD 

2.0, 3.0, 10.0, 20.0, or 30.0 Meters

18.2 [0.72]

39.0 [1.54]

25.0 [0.99]

104.3 [4.11]

90.4 [3.56]

67.0 [2.64]

Scan plane

M5 x 0.8,

DEPTH 9.0 [0.35] 

MAX (x4)

121.0 [4.77]

MTG holes

41.4 [1.63]

MTG holes

133.0 [5.24]

70.8 [2.79]

140.4 [5.53]

100.0 [3.94]

104.5 [4.12]

32.8 [1.29]

57.0 [2.25]

6.0 [0.24]

50.4 [1.99]

142.7 [5.62]

88.2 [3.47]

71.5 [2.82]

270 [10.63]

102.9 [4.05]

I/O cable assy

Back view

Bottom view

Side view

Front view

Top view

Ethernet cable

OS32C_tecPart_rev04.fm  Seite 11  Donnerstag, 2. Oktober 2014  9:36 09

Summary of Contents for OS32C Series

Page 1: ...risparmio energetico per AGV Interfaccia EtherNet IP per una facile connessione con il controllore standard Semplicit di configurazione delle zone mediante PC industrial omron eu OS32C Scanner laser...

Page 2: ...una nuova programmazione Tempo di risposta impostabile tra 80 e 680 ms Opzioni per l accesso ai cavi Funzione di monitoraggio del confine di riferimento Profilo basso per 104 5 mm 133 0 mm 142 7 mm 1...

Page 3: ...rilevamento del braccio possibile grazie alla modifica della risoluzione minima dell oggetto su 30 40 50 o 70 mm mediante l uso del software di configurazione La dimensione massima della zona di sicur...

Page 4: ...cita di sicurezza OFF Si verifica un gap L adeguamento del tempo di risposta consente di filtrare i rilevamenti errati arresto della macchina dovuti alla presenza di agenti inquinanti nell ambiente Te...

Page 5: ...put voltage is input voltage 2 0 VDC 5 Total consumption current of 2 OSSDs auxiliary output and warning output must not exceed 700 mA Auxiliary output Non safety NPN PNP transistor 1 load current of...

Page 6: ...bled Start restart interlock 1 External devices ED1 ED2 are forced guide relays G7Z G7SA G7S etc 2 If the External Device Monitoring is not used connect brown white wires to 0 V and then turn OFF the...

Page 7: ...44 00 11 industrial omron dk Finlandia Tel 358 0 207 464 200 industrial omron fi Francia Tel 33 0 1 56 63 70 00 industrial omron fr Germania Tel 49 0 2173 680 00 industrial omron de Norvegia Tel 47 22...

Reviews: