6-2-3
Power OFF Using the Power ON/OFF Input
1
Ensure all programs are closed.
If required, close all active programs.
2
Supply a 24 VDC signal to the Power ON/OFF Input (pins 3 and 4) of the I/O connector.
The input signal must remain ON for a minimum of 60 ms and a maximum of 750 ms to be
correctly detected by the Industrial Box PC.
The Industrial Box PC will shutdown.
Note that this behaviour can be reconfigured with the Power Options settings.
3
Wait until the PWR LED is OFF.
The Box PC is powered OFF.
Additional Information
• Refer to
4-2-2 I/O Connector Specifications
on page 4 - 14 for connector specifications.
• Refer to
on page 5 - 37 for wiring details.
6-2-4
Forced Power OFF Using the Power Button
Precautions for Safe Use
Press the power button for several seconds to force the product shutdown. Always back up files
in the planned way to prevent data loss or system file corruption.
1
Ensure all programs are closed.
If required, close all active programs to prevent losing unsaved data.
2
Press and hold the power button on the Box PC for 5 to 10 seconds.
Refer to
on page 2 - 7 for power button location information.
The Industrial Box PC will power OFF.
Any optional operating system settings related to power OFF will be disregarded.
3
Wait until the PWR LED is OFF.
The Box PC is powered OFF.
Confirm normal operation and check all product settings because unsaved data was lost.
6 Operating Procedures
6 - 4
NY-series Industrial Box PC User's Manual (W553)
Summary of Contents for NYB17-11
Page 30: ...Sections in this Manual 28 NY series Industrial Box PC User s Manual W553...
Page 38: ...1 Overview 1 8 NY series Industrial Box PC User s Manual W553...
Page 60: ...2 Hardware 2 22 NY series Industrial Box PC User s Manual W553...
Page 218: ...7 Maintenance 7 42 NY series Industrial Box PC User s Manual W553...
Page 239: ...I Index I 1 NY series Industrial Box PC User s Manual W553 I...
Page 242: ......
Page 243: ......