background image

14

15

Using Video Inputs

The NS-CA002 has joined the NS-CA001 Video Input Unit.

Console

Console

RGB

Camera

Camera

You may want to input moving images 
from a video camera or the image 
output from a Vision Sensor, arrange 
them on the PT screen, and capture 
(save) the images or display the capture 
data on the PT.

Display PC Screens with the NS-CA002

NS-CA002 RGB/Video Input Unit 

(Supported by the NS12-V   /NS10-V   /NS8-V   .)

An analog RGB input terminal is provided in addition to two 
video input interface terminals. A single video or analog 
RGB display is possible on the NS-series PT. In that case, 
video display is possible in user-defined positions and sizes. 
Touch switches and parts, such as lamps, can be 
overlapped on the video display. The display of parts will 
not disappear.

NS-CA001 Video Input Unit

(Supported by the NS12-V   /NS10-V   /NS8-V   .)

Four video input interfaces are provided, so four video or 
CCD cameras can be connected. Up to four images can be 
displayed simultaneously if the image size is 320x240 
pixels.

Image capture data read function

BMP data captured and saved in a Memory Card can be 
read on the PT. BMP data displayed in thumbnails 
can be selected and displayed on the captured data display 
screen that will appear for the command button.

If an error occurs, the image when the error occurred can be displayed 
on the NS screen. This is useful for on-site error analysis.

Note

: Two video signals cannot be simultaneously input to a 

          single screen.

Saving Displayed Video Images to a Memory 
Card in BMP Format

Image Capture Function 

When necessary, the displayed image can be captured and 
saved in a Memory Card in BMP format. The saved image 
can then be uploaded from remote personal computer via 
Ethernet or Serial connection.
The number of images that can be saved depends on the 
capacity of Memory Card. As an example, about 50 images 
from a 640x480 display (about 600 Kbytes each) can be 
saved in a 30-Mbyte Memory Card.

PT System 

Ver. 6 or Higher

For Operators

For Experts

Display machine 

status simply.

Display PLC memory 

areas without using tools.

Display program 

without using tools

Display machine 

status simply.

Do not want to be aware of 
ladder programs and PLC 
memory areas. 
Only want to display I/O 
comments and I/O status.

Display PLC memory 

areas without using tools.

Want to display and change the 
PLC memory areas without 
showing the PLC program.

Display program 

without using tools

Want to identify the fault location 
by checking the actual PLC 
program.
Want to change part of the 
program, a timer/counter, without 
connecting tools.

The NS monitors machine status for who and how machines 
are managed to help speed recover from problems.

Monitoring and Setting PLC Data

Ladder Monitor Function 

(NS12-V   /NS10-V   /NS8-V   )

The Ladder Monitor Software provided with the 
CX-Designer can be used to monitor states, 
search for addresses and instructions, and 
monitor multiple I/O points at the same time in 
CS/CJ-series PLCs ladder programs via a serial, 
Controller Link, or Ethernet connection. Copy 
the Ladder Monitor software to a Memory Card 
and install the Memory Card in the NS-series PT 
to enable these monitoring and searching 
operations. It is also possible to display I/O 
comments created with the CX-Programmer 
using an I/O Comment Extract Tool.

Monitoring Execution of 
the PLC's Ladder Program

Switch Box Function

The Switch Box Function has been added to the 
NS-series Programmable Terminals. The Switch 
Box Function can be used to monitor the status 
of each bit in a word or a combination of user-
selected bits organized like a ladder program 
section. The Switch Box Function makes it 
possible to perform basic troubleshooting on 
the factory floor even without a computer.

Easily Displaying the Status of 
Particular Bits in Ladder Programs 
when Errors Occur

Device Monitor Function

The Device Monitor Function is a standard feature 
in the NS-series Programmable Terminals. Data in 
the PLC’s I/O memory can be accessed directly 
(read and written.) The Device Monitor provides 
functions that can significantly reduce the time 
needed to set up the system, such as displaying a 
block of consecutive PLC data area addresses and 
inputting/verifying parameters in CPU Bus Units 
and Special I/O Units.

Monitoring PLC I/O Data for 
the Purpose of Device Debugging 
and Maintenance

Solve with the Ladder Monitor 
function

Solve with the Switch Box 
function

Solve with the Device Monitor 
function

Facilitate Equipment Maintenance

Smart Active Parts 

The following Smart Active Parts are provided and can be installed on the NS-Designer (version 6 or higher).

For CS/CJ AND CS1D CPU Unit

Error Log Monitor, Online Battery Change Button, etc.

For Serial Communications Boards/Units

Communications Status Displays (Error Monitor), Ports Settings, etc.

For Ethernet Units/CLK Units

Network Status Displays (Error Monitor and Network Node Status), etc.

For MC/MCH Unit

JOG Running, Search Zero Position, Program Running, Error Displays, 
I/O Status Monitor, PV Monitor, etc.

For NC/NCF Unit

JOG Running, Direct Running, Memory Running (NC Only), Error 
Displays I/O Status Monitor, PV Monitor, etc.

Wireless Terminals for WT30

Monitoring Slave Operating Status in a Wireless Environment

For Servo (R88D-WT, R7D-AP)

 

(See note.)

PV Monitor, Parameter Settings, Error Displays, Driver Information 
Displays, I/O

 

Status Monitor, etc.

For Inverters (See note.)

Rotation Speed/Monitoring Output Frequency, Other Parameter 
Settings, etc.

For DeviceNet

DRT2 Maintenance/Status Information, IN/OUT Information, etc.

For Temperature Controllers (E5   R, E5ZN, E5   N and 
CJ1W-TC)

Run Monitor, PID Settings SP Settings, Alarm Settings, Input 
Correction Settings, etc.

For Sensors (E3X-DRT)

Threshold Settings, Monitoring Light Reception Levels, Etc. 

For the SmartSlice GRT1 Series

Communications Unit Status, Warning/Alarm Flags, Network 
Joining/Leaving Status

Integrating Special Unit Functions or Component Peripheral Tool Functions into PTs

Note

: Smart Active Parts require a Serial Communications Units/Boards  

           (version 1.2 or later).

From CX-Designer version 1.0, the Ladder Monitor software is 
stored in the following folder on the CD-ROM. Copy it to a Memory 
Card (sold separately) to use it.
CX-One Disk 3: \Utility\CX-Designer\English\    
                          LadderMonitorFunc.
CX-Designer CD-ROM: \Utility\English\LadderMonitorFunc.

Summary of Contents for NS10-V2

Page 1: ...BE RESPONSIBLE FOR SPECIAL INDIRECT OR CONSEQUENTIAL DAMAGES LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS WHETHER SUCH CLAIM IS BASED ON CONTRACT WARRANTY NEGLIGENCE OR ST...

Page 2: ...r s energy expenditure from machine design to troubleshooting Switch Operation Touch Screen Operation Switch Operation Touch Screen Operation Machine Management Machine Management OK Smart Seamless It...

Page 3: ...usly a DeviceNet Configurator was required ThermoTool was required in the past With an NS series PT just drag and drop Smart Active Parts to customize the interface for your machine Wouldn t it be sim...

Page 4: ...long labels in English will fit within the frame limits after automatic font adjustment Convenient CSV or Unicode text 6 7 Previous When the System is Started When an Error Occurs during Operation PT...

Page 5: ...096 colors 20 Mbytes Version 2 Released for All NS series Models Greater Screen Capacity and Increased Visibility Now On Sale The NSH5 5 inch Hand held PT Just What You ve Been Waiting for The NS5 STN...

Page 6: ...in color by USB compatible printers Three times the image data capacity for standard models NS V2 32 000 colors Displays image data BMP and JPG beautifully High definition NS V2 Hardware Means High Q...

Page 7: ...ouple input Temperature resistance input Temperature input Analog input Thermocouple input Temperature resistance input Powerful Networking NS series PT NS series PT CS CJ series PLC CS CJ series PLC...

Page 8: ...nitor software to a Memory Card and install the Memory Card in the NS series PT to enable these monitoring and searching operations It is also possible to display I O comments created with the CX Prog...

Page 9: ...the mouse the functional objects on the test screen will change the corresponding address in the virtual PLC Conversely changing the content of a virtual PLC address will change the corresponding func...

Page 10: ...227 249 140 1 0 302 165 5 220 5 SLAVE HOST DC 24V RESET SW ETHERNET PORT A PORT B 49 9 13 7 23 3 8 90 4 Dimensions NS12 10 PT Units mm NS5 PT Units mm NS8 PT Units mm 39 min 42 max 39 min 42 max Recom...

Page 11: ...ntact your nearest OMRON representative to replace the backlight Communications Specifications Serial Communications Controller Link Wired type Specifications Ethernet Specifications Video Input Speci...

Page 12: ...S5 MQ00 V2 NS5 MQ00B V2 NS5 MQ01 V2 NS5 MQ01B V2 NSH5 SQR001B V2 NS5 TQ00B V2 NS5 TQ01 V2 NS5 TQ01B V2 Model number Model name Specifications Cable See note 1 NSH5 Cables NSH5 Wall mounting Bracket PT...

Page 13: ...tion Industrial Automation Company http www ia omron com c Copyright OMRON Corporation 2007 All Rights Reserved In the interest of product improvement specifications are subject to change without noti...

Reviews: