background image

2

General-purpose Relays

 

MK-S New Model

Ordering Information

List of Models

List of Models (Order Separately)

Type

Termi-

nals

Contact form

Internal connections 

(See note 3.)

With mechanical indicator With mechanical indicator 

and lockable test button

Coil ratings

Standard 
Models

Plug-in

DPDT

Standard

MKS2P

MKS2PI

AC/DC

Non-standard

MKS2P-2

MKS2PI-2

3PDT

Standard

MKS3P

MKS3PI

Non-Standard

MKS3P-2

MKS3PI-2

MKS3P-5

MKS3PI-5

Models with 
LED Indicator 
(See note 2.)

DPDT

Standard

MKS2PN(1)

MKS2PIN(1)

AC/DC

Non-standard

MKS2PN(1)-2

MKS2PIN(1)-2

3PDT

Standard

MKS3PN(1)

MKS3PIN(1)

Non-Standard

MKS3PN(1)-2

MKS3PIN(1)-2

MKS3PN(1)-5

MKS3PIN(1)-5

Models with 
Diode
(See note 2.)

DPDT

Standard

MKS2P(1)-D

MKS2PI(1)-D

DC

Non-standard

MKS2P(1)-D-2

MKS2PI(1)-D-2

3PDT

Standard

MKS3P(1)-D

MKS3PI(1)-D

Non-Standard

MKS3P(1)-D-2

MKS3PI(1)-D-2

MKS3P(1)-D-5

MKS3PI(1)-D-5

Models with 
LED Indicator 
and Diode

DPDT

Standard

MKS2PN-D

MKS2PIN-D

DC

Non-standard

MKS2PN-D-2

MKS2PIN-D-2

3PDT

Standard

MKS3PN-D

MKS3PIN-D

Non-Standard

MKS3PN-D-2

MKS3PIN-D-2

MKS3PN-D-5

MKS3PIN-D-5

Models with 
Varistor

DPDT

Standard

MKS2P-V

MKS2PI-V

AC

Non-standard

MKS2P-V-2

MKS2PI-V-2

3PDT

Standard

MKS3P-V

MKS3PI-V

Non-Standard

MKS3P-V-2

MKS3PI-V-2

MKS3P-V-5

MKS3PI-V-5

Models with 
LED Indicator 
and Varistor

DPDT

Standard

MKS2PN-V

MKS2PIN-V

AC

Non-standard

MKS2PN-V-2

MKS2PIN-V-2

3PDT

Standard

MKS3PN-V

MKS3PIN-V

Non-Standard

MKS3PN-V-2

MKS3PIN-V-2

MKS3PN-V-5

MKS3PIN-V-5

Item

Type

Model

Track-mounted Socket 8-pin

PF083A-E

11-pin

PF113A-E

8-pin

PF083A-D

11-pin

PF113A-D

Hold-down Clip 
(For PF083A-E and PF113A-E)

PFC-A1

Rated voltage

Note: 1.

 When ordering, add the rated voltage to the model number. Rated voltages are given in the coil ratings table in the specifications.

   Example: MKS3P 24 VDC

 

2.

 The DC coil comes in two types: standard coil polarity and reverse coil polarity.

  

Refer 

to 

Terminal Arrangement and Internal Connections

.

   Example: MKS2PIN1-2 24 VDC

 

3.

 Refer to 

Terminal Arrangement and Internal Connections

 for non-standard internal 

connections

.

Reverse coil polarity

Summary of Contents for MK-S - 2

Page 1: ...Blank Mechanical indicator I Mechanical indicator and lockable test button 4 LED Indicator Blank Standard N LED indicator 5 Coil Polarity Blank Standard 1 Reverse polarity DC coil only 6 Surge Absorp...

Page 2: ...standard MKS2PN D 2 MKS2PIN D 2 3PDT Standard MKS3PN D MKS3PIN D Non Standard MKS3PN D 2 MKS3PIN D 2 MKS3PN D 5 MKS3PIN D 5 Models with Varistor DPDT Standard MKS2P V MKS2PI V AC Non standard MKS2P V...

Page 3: ...0 Hz 60 Hz AC 6 V 443 mA 385 mA 3 1 80 max of rated voltage 30 min of rated voltage at 60 Hz 25 min of rated voltage at 50 Hz 110 of rated volt age Approx 2 3 VA at 60 Hz Approx 2 7 VA at 50 Hz 12 V 2...

Page 4: ...ngle amplitude 1 5 mm double amplitude Malfunction 10 to 55 to 10 Hz 0 5 mm single amplitude 1 0 mm double amplitude Shock resistance Destruction 1 000 m s2 approx 100 G Malfunction 100 m s2 approx 10...

Page 5: ...urning Round terminals cannot be used for finger protection models Use Y shaped terminals 52 5 max 34 5 max 34 5 max 0 8 34 5 max 34 5 max 52 5 max 0 8 Socket Surface mounting Socket for track or scre...

Page 6: ...0 A2 9 34 3 14 4 12 8 32 38 8 30 Terminal Arrangement Mounting Holes Two M4 or two 4 5 dia hole Eight M4 screws PFC A1 4 6 62 60 8 4 5 6 2 pieces per set 4 5 15 25 25 25 25 10 10 1000 500 7 3 0 15 35...

Page 7: ...2 MKS3P I 1 D 5 Models with LED indicator DC Coil MKS2P I N D MKS2P I N D 2 MKS3P I N D MKS3P I N D 2 MKS3P I N D 5 Bottom View 1 2 3 4 5 6 7 8 8 6 3 1 2 7 4 5 1 2 3 4 5 6 7 8 10 11 9 9 11 10 8 7 6 5...

Page 8: ...tary testing position and go straight into the locked position Use an insulated tool when you operate the test button Models with test buttons or LED indicators fulfill the requirements for reinforced...

Page 9: ...General purpose Relays MK S New Model 9...

Page 10: ...10 General purpose Relays MK S New Model...

Page 11: ...General purpose Relays MK S New Model 11...

Page 12: ...he product on which liability is asserted IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY REPAIR OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROP...